Thromb Haemost 1975; 33(03): 547-552
DOI: 10.1055/s-0038-1647848
Original Article
Schattauer GmbH

Performances of an Artificial Reagent for the One-stage Factor IX Assay

Authors

  • L Meunier

    1   Center for Haemophilic Children, Croix-Rouge Française, La Queue-les-Yvelines, the Unit 56 of the I.N.S.E.R.M. and the National Blood Center 75015 Paris, France
  • J. P Allain

    1   Center for Haemophilic Children, Croix-Rouge Française, La Queue-les-Yvelines, the Unit 56 of the I.N.S.E.R.M. and the National Blood Center 75015 Paris, France
  • D Frommel

    1   Center for Haemophilic Children, Croix-Rouge Française, La Queue-les-Yvelines, the Unit 56 of the I.N.S.E.R.M. and the National Blood Center 75015 Paris, France
Further Information

Publication History

Received 07 October 1974

Accepted 12 February 1975

Publication Date:
02 July 2018 (online)

Preview

Summary

A mixture of adsorbed normal human plasma and chicken plasma was prepared as reagent for factor IX measurement using a one-stage method. The substrate was found to be specific for factor IX. Its performances tested on samples displaying factor IX activity ranging from <l%–2,500% compared favorably with those obtained when using the plasma of severe haemophilia B patients as substrate.