Vet Comp Orthop Traumatol 2018; 31(05): 339-343
DOI: 10.1055/s-0038-1660873
Original Research
Georg Thieme Verlag KG Stuttgart · New York

Repeatability of Three-Dimensional Computed Tomographic Volumetric Measurement of Lumbosacral Intervertebral Foramina in German Shepherd Dogs

Stefan Gordon
1   Massey University Veterinary Teaching Hospital, Massey University, Palmerston North, New Zealand
,
Janis P. Bridges
1   Massey University Veterinary Teaching Hospital, Massey University, Palmerston North, New Zealand
,
Susan C. Tomlin
1   Massey University Veterinary Teaching Hospital, Massey University, Palmerston North, New Zealand
,
Angela Hartman
2   NZEVET, Nelson, New Zealand
,
Andrew J. Worth
1   Massey University Veterinary Teaching Hospital, Massey University, Palmerston North, New Zealand
2   NZEVET, Nelson, New Zealand
3   Massey University Working Dog Centre, Massey University, Palmerston North, New Zealand
› Author Affiliations
Further Information

Publication History

15 December 2017

01 May 2018

Publication Date:
23 August 2018 (online)

Abstract

Objectives This article determines the repeatability of a recently reported method of volumetric measurement of the lateral intervertebral neurovascular foramina at the lumbosacral junction in German shepherd dogs.

Materials and Methods Batch files including the intervertebral neurovascular foramina were derived from previously obtained computed tomography studies of the extended lumbosacral junction of 20 German shepherd dogs and converted into volume datasets. Three observers independently performed five measurements of the left and right lumbosacral intervertebral neurovascular foramina in each dog, using an Extended Brilliance Workstation (Phillips, The Netherlands) to generate a volume of the lumbosacral intervertebral foramina in cubic millimetres, as described by Worth and colleagues in 2017. The inter-observer repeatability of the mean of the five-volume measurements (40 foramina) was assessed using the Bland–Altman limits of agreement method. One observer, blinded to the previous measurements, repeated the volumetric analysis on 20 lumbosacral intervertebral foramina for an assessment of intra-observer repeatability using the same statistical methods.

Results This method of volumetric analysis showed good intra- and inter-observer repeatability with 95% of paired comparisons falling within two standard deviations of the mean difference between them.

Clinical Significance This method of measuring the volume of the lumbosacral intervertebral neurovascular foramina is repeatedly reliable and may be a useful tool when testing the effects of motion and disease on the lumbosacral junction, and could help guide surgical intervention when foraminal narrowing is implicated in the clinical signs.

Author Contributions

Stefan Gordon and Andrew J. Worth contributed to conception of study, study design and acquisition of data and data analysis and interpretation. Janis P. Bridges and Susan C. Tomlin contributed to study design and acquisition of data and data analysis and interpretation. Angela Hartman contributed to conception of study and study design. All authors drafted, revised and approved the submitted manuscript.


 
  • References

  • 1 Meij BP, Bergknut N. Degenerative lumbosacral stenosis in dogs. Vet Clin North Am Small Anim Pract 2010; 40 (05) 983-1009
  • 2 Worth AJ, Thompson DJ, Hartman AC. Degenerative lumbosacral stenosis in working dogs: current concepts and review. N Z Vet J 2009; 57 (06) 319-330
  • 3 Gödde T, Steffen F. Surgical treatment of lumbosacral foraminal stenosis using a lateral approach in twenty dogs with degenerative lumbosacral stenosis. Vet Surg 2007; 36 (07) 705-713
  • 4 Rapp M, Ley CJ, Hansson K, Sjöström L. Postoperative computed tomography and low-field magnetic resonance imaging findings in dogs with degenerative lumbosacral stenosis treated by dorsal laminectomy. Vet Comp Orthop Traumatol 2017; 30 (02) 143-152
  • 5 Jones JC, Davies SE, Werre SR, Shackelford KL. Effects of body position and clinical signs on L7-S1 intervertebral foraminal area and lumbosacral angle in dogs with lumbosacral disease as measured via computed tomography. Am J Vet Res 2008; 69 (11) 1446-1454
  • 6 Worth AJ, Hartman A, Bridges JP, Jones BR, Mayhew JI. Computed tomographic evaluation of dynamic alteration of the canine lumbosacral intervertebral neurovascular foramina. Vet Surg 2017; 46 (02) 255-264
  • 7 Higgins BM, Cripps PJ, Baker M, Moore L, Penrose FE, McConnell JF. Effects of body position, imaging plane, and observer on computed tomographic measurements of the lumbosacral intervertebral foraminal area in dogs. Am J Vet Res 2011; 72 (07) 905-917
  • 8 Bland JM, Altman DG. Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol 2003; 22 (01) 85-93
  • 9 Bartlett JW, Frost C. Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables. Ultrasound Obstet Gynecol 2008; 31 (04) 466-475
  • 10 Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1 (8476): 307-310
  • 11 Bland JM, Altman DG. Agreed statistics: measurement method comparison. Anesthesiology 2012; 116 (01) 182-185
  • 12 Danielsson F, Sjöström L. Surgical treatment of degenerative lumbosacral stenosis in dogs. Vet Surg 1999; 28 (02) 91-98
  • 13 Smith GA, Aspden RM, Porter RW. Measurement of vertebral foraminal dimensions using three-dimensional computerized tomography. Spine 1993; 18 (05) 629-636