Keywords dog - articular fracture - 3D printing - 3D computer-assisted surgical planning -
virtual surgery
Introduction
Femoral fractures are frequently encountered in clinical small animal practice, accounting
for 45% of all long bone fractures.[1 ]
[2 ] Trauma is a common cause of femoral fractures, such as vehicular accidents or falls
from great heights. A small subset includes those fractures that affect the supracondylar
and condylar regions, representing 8 to 10% of all femoral fractures.[1 ]
[2 ]
[3 ]
[4 ] These fractures pose unique challenges to veterinary surgeons due to the limited
bone stock available for fixation and articular involvement, requiring anatomical
reconstruction and rigid fixation via interfragmentary compression.[5 ] Therefore, a carefully constructed preoperative plan is critical for successful
fixation.[6 ] Various pre-surgical planning techniques may be utilized based on orthogonal radiographs
of the affected limb. However, severe displacement of fracture fragments in multiple
dimensions can increase the difficulty of applying traditional planning techniques
to comminuted articular fractures.
Computed tomography (CT) is a useful diagnostic modality that allows for further characterization
of fracture configuration to assist with surgical planning, particularly when 3D rendering
of images is performed. However, visualization of 3D images on a flat screen may not
provide the veterinary surgeon with an adequate understanding of complex anatomical
relationships,[7 ]
[8 ]
[9 ] such as in the case of severely comminuted fractures. Furthermore, although the
3D-rendered images can be manipulated, preoperative planning in the form of fragment
reduction and selection of appropriate implants cannot be performed.
Three-dimensional (3D) printing or additive manufacturing, previously known as rapid
prototyping, is becoming increasingly popular in veterinary medicine as a method of
reproducing bone replicas for management of orthopaedic cases.[10 ]
[11 ]
[12 ]
[13 ]
[14 ]
[15 ]
[16 ]
[17 ] In addition, 3D computer-assisted surgical planning (CASP) has many clinical applications
in reconstructive surgery in human and veterinary medicine.[9 ]
[14 ]
[18 ] To the authors' knowledge, there is no current literature reporting the use of 3D
CASP and printing in the repair of an articular fracture in veterinary medicine. This
report describes the process of 3D CASP and the use of a 3D printed model to facilitate
complex articular femoral fracture repair in a dog.
Case Description
A 4-year-old, 32.6 kg, male neutered, Golden Retriever was presented to the Michigan
State University Veterinary Medical Center for the evaluation of an acute onset non–weight-bearing
right hindlimb lameness after jumping out of a second story window. On initial evaluation,
the dog was quiet and alert with normal vital parameters. Orthopaedic examination
revealed a non–weight-bearing right hindlimb lameness with crepitus present on palpation
of the right distal femur. The results of haematology were within normal limits. Serum
biochemical analysis revealed a mildly elevated aspartate transaminase and creatine
kinase. Radiographs and CT images (GE Revolution EVO scanner, 0.63 mm slices, kVp = 120,
mA = 193: GE Healthcare, Milwaukee, Wisconsin, United States) of the hindlimbs revealed
a closed, severely comminuted, right distal femoral supracondylar and bicondylar fracture
with articular involvement, as well as multifragmentary comminution of the caudolateral
femoral metaphysis ([Fig. 1 ]).
Three-Dimensional Computer-Assisted Surgical Planning and Printing
The CT images were converted to a 3D format using modelling software (Mimics Innovation
Suite 19: Materialise NV, Leuven, Belgium). The fracture fragments were segmented
virtually to create five main fragments: proximal femur, lateral condyle, medial condyle,
trochlea, and medial metaphysis ([Fig. 1C ], [D ]). The virtual fragments were reduced with computer-aided design (CAD) software (Meshmixer
3.2: Autodesk, Inc, San Rafael, California, United States) by comparing them to a
mirror image of the contralateral, unaffected femur. Following fracture reduction,
various-sized cylinders (1.5, 2.7 and 4.0 mm in diameter) were applied to the virtual
model to simulate screw placement ([Fig. 2A ], [B ]). A 3.5-mm reconstruction plate was applied virtually to the medial aspect of the
distal femur ([Fig. 2C ], [D ]). Application of a lateral plate was not simulated as the surgeon had determined
that a locking plate and monocortical screws were to be used. The virtually reduced
femoral fracture, including the five main fragments, was printed using a stereolithography
3D printer (Form 2: Formlabs, Somerville, Massachusetts, United States). A 3.5-mm
reconstruction plate (DePuy Synthes Inc., West Chester, Pennsylvania, United States)
was pre-contoured to the distomedial aspect of the printed model to ensure that lag
screws could be placed through the distal plate holes ([Fig. 2E ]). The plate was then steam sterilized.
Fig. 1 Preoperative imaging of the left femur. (A ) Craniocaudal radiograph. (B ) Lateral radiograph. (C ) Cranial view of CT rendered image. (D ) Caudal view of CT rendered image. Abbreviations: CT, computed tomography; LC, lateral
condyle; MC, medial condyle; MM, medial metaphysis; P, proximal femur; T, trochlea.
Fig. 2 (A–D ) Images from computer-aided design software with simulation of screw (via cylinders)
and reconstruction plate placement. (E ) Three-dimensional printed model with pre-contoured reconstruction plate applied
to the medial aspect of the distal femur.
Anaesthesia
The dog was sedated with fentanyl (3µg/kg intravenous [IV]) and dexmedetomidine (3
µg/kg IV). General anaesthesia was induced with propofol (1 mg/kg IV) and midazolam
(0.2 mg/kg IV), followed by isoflurane and oxygen maintenance. Lactated Ringer's solution
(10 mL/kg/h IV) and fentanyl (3–5 µg/kg/h continuous rate infusion [CRI] IV) were
administered intraoperatively. The dog was treated with cefazolin (22 mg/kg IV every
90 minutes) and a single dose of carprofen (2.2 mg/kg subcutaneous [SQ]) perioperatively.
Surgery
Surgery was performed to stabilize the femoral fracture, as previously planned with
3D CASP and preoperative surgical rehearsal. The dog was placed in dorsal recumbency.
A craniolateral surgical approach to the right distal femur was made, and a lateral
parapatellar arthrotomy was performed[19 ] ([Fig. 3A ]). The cruciate ligaments, collateral ligaments and menisci were intact. The lateral
condylar and trochlear fracture fragments were reduced and stabilized with a 1.5 mm
positional screw (DePuy Synthes Inc., West Chester, Pennsylvania, United States).
The medial condyle was then reduced to this unit and interfragmentary stabilization
was achieved with a 4.0 mm cancellous screw (DePuy Synthes Inc., West Chester, Pennsylvania,
United States) and washer (DePuy Synthes Inc., West Chester, Pennsylvania, United
States) placed in a lag fashion ([Fig. 3B ]). Two 1.1 mm Kirschner wires (IMEX Veterinary Inc., Longview, Texas, United States)
were placed in a mediolateral direction across the condyles and trochlea for temporary
stabilization. The medial metaphyseal fragment was reduced to the proximal fragment.
Compression of the two fragments resulted in collapse; therefore, the two fragments
were stabilized with a 2.7 mm positional screw (DePuy Synthes Inc., West Chester,
Pennsylvania, United States) and a 1.1 mm Kirschner wire (IMEX Veterinary Inc., Longview,
Texas, United States). The two resulting composite fragments (lateral condyle + trochlea + medial
condyle and proximal femur + medial metaphysis) were reduced and the pre-contoured
3.5-mm reconstruction plate was applied to the distomedial aspect of the femur, over
the temporary Kirschner wires. The Kirschner wires were replaced with 4.0-mm cancellous
screws (DePuy Synthes Inc., West Chester, Pennsylvania, United States) placed in lag
fashion through the two distal-most plate holes ([Fig. 3C ]). Two additional 3.5-mm bicortical screws (DePuy Synthes Inc., West Chester, Pennsylvania,
United States) were placed in the two proximal-most holes of the reconstruction plate.
A 2.7-mm String-of-Pearls plate (String-of-Pearls plate: Orthomed Ltd, Huddersfield,
West Yorkshire, United Kingdom) was applied to the lateral aspect of the distal femur,
and four 2.7-mm monocortical screws (DePuy Synthes Inc., West Chester, Pennsylvania,
United States) were placed ([Fig. 3D ]). The surgical site was lavaged copiously with sterile saline, followed by routine
closure. No intraoperative complications were encountered. Recovery from surgery was
uneventful.
Fig. 3 Intraoperative images obtained (A ) prior to reduction, (B ) following reduction in lateral condylar and trochlear fragment to medial condyle,
(C ) application of screws and reconstruction plate and (D ) following placement of all implants.
Postoperative Period
Postoperative right femoral radiographs revealed appropriate alignment and positioning
of the implants ([Fig. 4A ], [D ]), with similar results compared with those achieved with 3D CASP. In the immediate
postoperative period, analgesia was provided with fentanyl (3–4 μg/kg/h CRI) for the
first 24 hours, followed by tramadol therapy (3 mg/kg per os [PO] q8–12h). Metoclopramide
(2 mg/kg/day CRI) therapy was initiated due to regurgitation. Cefazolin administration
(22 mg/kg IV q12h) was continued until discharge. The dog was discharged 2 days following
surgery with instructions to the owner to administer carprofen (2.2 mg/kg PO q12h
for 10 days), tramadol (3 mg/kg PO q8–12h for 10 days), cephalexin (22 mg/kg PO q12h
for 14 days), metoclopramide (0.3 mg/kg PO q8h for 5 days) and trazodone (3 mg/kg
PO q8–12h for 14 days).
Fig. 4 Postoperative radiographs of the left femur. (A ) Immediate postoperative craniocaudal and (D ) lateral radiographs. (B ) Six-week postoperative craniocaudal and (E ) lateral radiographs. (C ) Eight-month postoperative craniocaudal and (F ) lateral radiographs.
The dog was re-evaluated at the Michigan State University Veterinary Medical Center
6 weeks following surgery. Orthopaedic examination revealed a mild, weight-bearing
right hindlimb lameness and moderate muscle atrophy of the right hindlimb. Radiographs
revealed stable implants and normal bone remodelling ([Fig. 4B ], [E ]). Goniometric measurements of the right stifle were obtained as previously described,[20 ] which revealed a mildly reduced extension angle (155°) and moderately reduced flexion
angle (60°) compared with the contralateral stifle (extension angle—160°, flexion
angle—40°).
Nine weeks postoperatively, the dog was re-evaluated again. Orthopaedic examination
revealed an intermittent, mild, weight-bearing right hindlimb lameness with improvement
in the degree of muscle atrophy. Goniometry revealed normal extension (160°) and mildly
reduced flexion (50°) of the right stifle.
A final re-examination conducted at 8 months postoperatively revealed no lameness
present at a walk or trot. Radiographs revealed unchanged implants and complete bone
healing ([Fig. 4C ], [F ]). Bilateral muscle symmetry was present at the level of the proximal thigh (33-cm
circumference). Goniometry revealed normal extension (160°) and flexion (42°) of the
right stifle.
Discussion
This report describes the successful clinical application of 3D CASP and printing
in the repair of a comminuted articular fracture in a dog. In this clinical case,
the 3D printed replica was instrumental in providing the surgeon with a custom model
depicting the anatomic relationship between fracture fragments. According to AO principles,[6 ] different techniques may be utilized in the preoperative planning stage. The direct
overlay technique involves reduction in fracture segments after tracing them individually
on pieces of paper. Another technique uses a mirror image of the contralateral (normal)
bone as a template for fracture reduction. The drawing of fracture lines directly
onto a cadaveric bone specimen from a similar-sized animal to facilitate selection
and pre-contouring of implants can also be performed. Due to the complex degree of
displacement and rotation present, it was nearly impossible to trace the shape of
the fracture fragments accurately based on two-dimensional (2D) views, such as orthogonal
radiographs. Instead, CAD software was used to manipulate each CT-derived fracture
fragment in 3D space. Direct fracture reduction in 3D fragments remained difficult
due to overlapping of the segments; therefore, the technique in which the contralateral
femur is used as a template for reduction was performed in this case. As with 2D planning,
3D CASP allowed for simulated placement of key implants, such as interfragmentary
lag screws, but in multiple planes. In addition, contouring and placement of a reconstruction
plate were performed virtually with the CAD software, allowing the surgeon to determine
the length, size and placement of the implant preoperatively. The printed 3D model
was used to facilitate pre-contouring of the plate selected through 3D CASP. It is
estimated that pre-contouring of the plate and increased surgeon confidence due to
preoperative rehearsal of the procedure reduce surgical time by 15 to 20 minutes.[14 ] There were no intraoperative delays or complications noted. However, direct comparisons
cannot be drawn between this procedure and a similar procedure performed without the
use of preoperative 3D CASP.
Intraoperatively, interfragmentary compression of the various fracture fragments was
achieved via placement of screws in lag fashion. To achieve superior compression,
lag screws were placed in a medial to lateral direction due to the limited bone stock
present medially compared with laterally. Screws were also preferentially placed through
plate holes to provide a better lag effect. Following placement of the medial reconstruction
plate and associated lag screws, a lateral locking plate was applied to distribute
bending forces between the two plates. This plate was not virtually applied during
3D CASP and pre-contoured preoperatively, as precise contouring of locking plates
is not critical to implant stability. Also, since monocortical screws were placed
rather than lag screws through the plate holes, the plate position on the bone surface
was of less importance.
The use of a 3D printed model can also facilitate client education and communication.
The 3D printed bone replica enhanced the client's understanding of the treatment plan,
potential complications and financial cost associated with moving forward with surgery.
Indeed, the visual and tactile feedback from a 3D model has been shown in human medicine
to improve patient understanding of anatomical details compared with 2D or 3D reconstructed
imaging.[9 ]
Acquiring a thorough knowledge of surgical anatomy is an essential objective for all
surgical residents and veterinary students. The utility of 3D printing in human surgical
training has been demonstrated in various disciplines.[21 ]
[22 ]
[23 ]
[24 ] To this end, the 3D printed bone replica in this case served as a tool with which
residents could simulate the surgical procedure, allowing for subjectively improved
understanding of the patient-specific anatomy. However, objective outcomes to measure
the utility of this modality in augmenting knowledge were not used. This may be an
area of interest for future studies investigating the utility of 3D CASP and printing.
The primary drawbacks to 3D CASP and printing are the associated costs and time. A
3D model typically takes at least 18 to 24 hours to print, depending on the size of
the replica.[14 ] Stereolithography is a 3D printing technology where epoxy resin or liquid photopolymer
is exposed to a low-power ultraviolet laser.[9 ] Although stereolithography is capable of yielding resolutions up to 25 μm,[9 ] a lower resolution was used in this report (100 μm) to reduce printing time. Since
CT images were obtained using thin slices with a thickness of 630 μm, the resolution
of the printed 3D bone replica was still six times finer than that of the CT images,
and is likely to be an appropriate resolution when it comes to the fabrication of
small models. This is supported by a study that evaluated the accuracy and repeatability
of CT-derived bone models produced by low-end and high-end 3D printers.[25 ] The cost and time associated with 3D printing was further reduced in this report
by performing 3D CASP beforehand. Three-dimensional CASP allowed the surgeon to focus
on the region of interest (distal femur) and reduce the 3D volume to be printed, therefore
reducing the amount of resin used. Overall, the 3D bone replica took 5 hours to print
with an associated cost of about US$10.
Conclusion
Three-dimensional CASP and printing is a rapidly emerging technique with a variety
of benefits, such as preoperative surgical planning, client education and training
of residents and students. Three-dimensional CASP and the clinical use of 3D printed
models in articular fracture repair have yet to be documented in veterinary literature,
probably because standard planning procedures are sufficient in the majority of cases.
However, in cases of complicated articular fractures, careful surgical planning using
3D CAD software and 3D printing may be indicated to reduce operating time and improve
the success rate of the procedure.