CC BY-NC-ND 4.0 · Journal of Clinical Interventional Radiology ISVIR 2022; 06(03): 212-216
DOI: 10.1055/s-0041-1741528
Case Series

Endovascular Rescue for Renal Artery Pseudoaneurysms following Minimally Invasive Robot-Assisted Partial Nephrectomy—A Case Series

1   Department of Interventional Radiology, HCG Hospital, Bengaluru, Karnataka, India
,
Vidya Bhargavi
1   Department of Interventional Radiology, HCG Hospital, Bengaluru, Karnataka, India
,
Indushekhar Subbanna
1   Department of Interventional Radiology, HCG Hospital, Bengaluru, Karnataka, India
,
Bharath KS
1   Department of Interventional Radiology, HCG Hospital, Bengaluru, Karnataka, India
,
Rajkumar Patel
2   Department of Uro-oncology and Robotic Surgery, HCG Hospital, Bengaluru, Karnataka, India
› Author Affiliations
 

Abstract

Nephron sparing surgery or partial nephrectomy has been employed ever since in cases of renal tumors with an aim to preserve the function of residual kidney. Lately, there has been increasing adoption in robot-assisted techniques for partial nephrectomy. However, renal surgeries of any kind have always been a hazard for postoperative vascular complications owing to high vascularity of the renal tissues, of which renal artery pseudoaneurysm is one of the most fatal complications. We present a case series where highly super-selective embolization rescues the patient and augments the nephron sparing nature of the precise robot-assisted partial nephrectomy.


#

Introduction

Robotic partial nephron sparing surgery (RPN) offers a minimally invasive surgical option, especially for patients presenting with smaller renal mass, and is being employed recently even for larger and complex lesions.[1] Postoperative massive hemorrhage, urine leak, and urinoma formation are few of the known complications following RPN. Renal artery pseudoaneurysms (RAP) are a relatively rare complication following nephron sparing surgery.[2] Development of RAP has been reported to be seen in the immediate postoperative period and also as a delayed presentation (>3 weeks).[2] With increasing utilization of nephron sparing surgery, the incidence is expected to be on rise. Here, we present a series of four cases presenting with RAP following RPN treated with super-selective endovascular measures with aim to preserve as much normal renal tissue as possible without jeopardizing the nephron sparing nature of surgery.


#

Case 1

A 62-year-old diabetic and hypertensive male presenting with multiple vomiting episodes was found to have an exophytic mass in the interpolar region of right kidney. Imaging showed no vascular thromboses and no distant metastases. He underwent RPN. Renorrhaphy was done in two layers. Warm ischemic time of 20 minutes and estimated blood loss (EBL) of 150 mL, RENAL score[3] 9xh were noted. On postoperative day 17, he presented with high-grade fever, chills, multiple episodes of vomiting, and generalized weakness. He was investigated and was found to have leukocytosis and hyponatremia. Despite aggressive medical treatment, he had high-grade fever and one episode of gross hematuria resulting in drop in hemoglobin levels. After being transfused with two units of packed cell red blood cells, he was taken up for angiography.

Angiogram of the right renal artery through a 5F vascular sheath (Radifocus Introducer II Standard Kit A, Terumo Medical Corporation, United States) and 4F Cobra C1 catheter (Glidecath, Terumo Medical Corporation, Corporation 265 Davidson Avenue Somerset, NJ 08873, United States) showed 23 × 19 mm pseudoaneurysm in the interpolar region. Super-selective embolization was done using 2.4F microcatheter (Direxion, Boston Scientific Corporation, United States) and microcoil of size 5 mm × 7 cm (Nester Embolization coil, Cook Medical LLC, United States). Postembolization angiogram showed no filling of the pseudoaneurysm ([Fig. 1]). Patient was eventually discharged in a satisfactory condition with no similar episodes later.

Zoom Image
Fig. 1 Catheter angiography (black arrow) and computed tomography volume-rendering technique image (white arrow) showing large saccular pseudoaneurysm in the interpolar region of right kidney. Angiography image post-super-selective embolization using microcoil (yellow arrow) shows no filling up of pseudoaneurysm.

#

Case 2

Screening ultrasonography (USG) of a 43-year-old male detected an incidental left renal mass that on contrast enhanced computerized tomography (CT) was a well-defined heterogeneously enhancing lesion in the interpolar region of left kidney suggesting a neoplasm, renal cell carcinoma. Patient underwent RPN. Renorrhaphy was done in two layers. Warm ischemia time of 34 minutes and EBL of 200 mL, and renal score 10X were noted. Nineteen days after the surgery, patient had few episodes of fever, dysuria, and hematuria. Patient was evaluated with CT renal angiogram and was found to have a pseudoaneurysm.

He was referred to the department of interventional radiology for further management. Angiogram of the left renal artery showed active contrast extravasation from the segmental branch in the interpolar region, which was seen to fill a large, 22 × 11mm pseudoaneurysm ([Fig. 2]). Super-selective embolization was done using 2.7F microcatheter (Progreat, Terumo Medical Corp., United States), 0.2 cc of n-butyl cyanoacrylate (NBCA) glue with lipiodol in the ratio of 1:2 and a coil of size 3 mm × 5 cm. Postembolization angiogram showed no active contrast extravasation and no filling of pseudoaneurysm ([Fig. 2]). Patient was followed up till 8 months and had no similar episodes.

Zoom Image
Fig. 2 Catheter angiography (black arrow) and computed tomography angiography image (white arrow) showing large saccular pseudoaneurysm in the interpolar region of left kidney. Angiography image post-super-selective embolization using microcoil (yellow arrow) shows absence in supply to the pseudoaneurysm.

#

Case 3

Routine health screening of a 43-year-old male revealed bilateral renal mass on USG. Contrast-enhanced CT (CECT) showed a 4.6 × 4.6 cm well-defined mass in the interpolar region of left kidney involving cortex and medulla with no vascular thromboses and a similar smaller 1.9 × 1.8 cm lesion in the upper pole of right kidney. Patient underwent RPN for the left renal mass. Renography was done in two layers. Warm ischemic time of 35 minutes and EBL of 150 mL, and RENAL score 10h were noted. Fourteen days after the surgery, patient presented with complaints of dysuria, fever, and hematuria. Patient was referred for angiography.

Angiogram of the left renal artery showed actively filling multiple pseudoaneurysms from the anteroinferior and posterior segmental branches in the lower and interpoles, largest measuring 22 × 11mm. Super-selective embolization of anteroinferior branches was done using 2.7F microcatheter and coils of size 6mm × 7cm and 4mm × 7cm. Posterior segmental branches were super-selectively embolized subsequently with coils of size 3 mm × 3cm and 5mm × 5cm. Technical success was confirmed with a postembolization angiogram showing no contrast extravasation ([Fig. 3]). Clinical success was confirmed with no episodes of hematuria, fever, and dysuria on follow-up beyond 6 months.

Zoom Image
Fig. 3 Catheter angiography showing multiple large pseudoaneurysms (black arrows) in the lower and interpolar region of left kidney. Angiography image post-super-selective embolization using multiple microcoils (yellow arrows) shows arrest in filling up of pseudoaneurysm.

#

Case 4

A 58-year-old male with complaints of abdominal pain was evaluated with CECT to have multiple left renal mass lesions. CT reported a lesion of size 3.6 × 3.6 cm on the medial aspect and a smaller 1.1 × 1.1 cm lesion in the later aspect of lower pole region of left kidney. He underwent left RPN. During the procedure, surgeons found a large lower pole tumor with two smaller partially exophytic small tumors nearby. Double-layered renorrhaphy was done. Warm ischemic time of 45 minutes and approximate blood loss of 100 mL, and RENAL score 10x were noted. Patient had an uneventful postoperative period. On day 42, after the surgery, patient complained of hematuria and blood clots in urine for 3 days. USG of the abdomen showed a focal heterogenous isoechoic area measuring 65 × 58mm with no internal vascularity at postoperative site abutting the mid pole of remnant left kidney, likely a hematoma.

Angiogram of the left renal artery showed active contrast extravasation from inferior segmental branches in the lower pole region to fill a large, 40 × 20 mm saccular pseudoaneurysm. Super-selective embolization was done using three coils of sizes 4 mm × 14 cm, 4mm x7cm, and 3mm × 7cm. Postembolization angiogram showed no active contrast extravasation ([Fig. 4]). Patient was stable with no hematuria post procedure. All the cases have been summarized in [Table 1].

Table 1

Summary of findings in the patients who underwent robot-assisted partial nephrectomy

Sl. no

Location of the renal mass

RENAL nephrometry score[3] of the lesion

Renorrhaphy

(layers)

Estimated blood loss (mL)

Warm ischemia time (minutes)

Time interval after surgery and symptoms

Symptoms at the time of presentation

Endovascular embolic agent(s) used

1.

Right—interpolar region

9xh

2

150

20

17 days

Fever, chills, vomiting, weakness

Coils

2

Left—interpolar region

10x

2

200

34

19 days

Fever, dysuria, hematuria

NBCA and coils

3.

Left—interpolar region

10h

2

150

35

14 days

Fever, dysuria, hematuria

Coils

4.

Left—lower pole

10x

2

100

45

39 days

Hematuria, clots in urine.

Coils

Abbreviations: A, anterior/posterior; E, exophytic/endophytic; L, location of tumor relative to polar lines; N, nearness of tumor to collecting system or a sinus; R, radius.


RENAL score components.[3]


Zoom Image
Fig. 4 Catheter angiography shows large saccular pseudoaneurysms (black arrow) in the lower pole region of left kidney. Angiography image post-super-selective embolization using microcoils (yellow arrow) shows the desired result.

#

Discussion

RAP is one of the most common vascular complications with etiologies ranging from trauma, iatrogenic causes like percutaneous biopsy, nephrostomy, and following surgical procedures like partial nephrectomy.[4]

Yamashita et al in their prospective study reported a significant 18% incidence of RAP following RPN. However, the study showed that smaller (<10mm) asymptomatic pseudoaneurysms can be managed conservatively and may resolve spontaneously. On the other hand, symptomatic and larger lesions need to be promptly intervened, failing which can even result in renal failure over time.[5]

All our patients with complex tumor, represented by higher RENAL nephrometry scores, are counseled about potential vascular complications and with informed consent are taken up for RPN. They are alerted about the warning signs like gross hematuria, and signs of infection at the time of discharge and are instructed to report immediately in such instances. The reported time interval between the surgery and development of a symptomatic pseudoaneurysm has varied widely ranging from 1 to 4 weeks. A study that reviewed almost a thousand cases of minimally invasive partial nephrectomy reported no case presenting after 25 days.[6] In our series, three patients presented within 21 days and only one patient presented late after 39 days. Affirmative reason for development of RAP is still a matter of debate, including but not limited to arterial transection, partial ligation of a small distal order branch, or missed ligation of branch in spasm, redirecting the suture needle while approximating the parenchymal defect of partial nephrectomy and longer operative and cold ischemia times. Technical caveats in surgery have been suggested to avoid potential cause for bleeding post-RPN.[1] [2] [7] [8] [9]

Catheter angiography and selective embolization have been established as the main course of treatment for patients presenting with hematuria, bleeding into the surgical drain, sudden onset abdomen and/or flank pain, refractory hypotension, tachycardia and drop in levels of hemoglobin following open or laparoscopic partial nephrectomy.[10] The purpose of minimal invasive nephron sparing surgery is to preserve the renal function.

Anatomy of renal artery and its divisions reveals that renal artery originating from abdominal aorta divides into anterior and posterior divisions. Anterior division further dividing into apical, upper, middle, and lower segmental arteries and the posterior division continues as posterior segmental artery with no collaterals/anastomoses between the segments rendering them as end arteries. Variations in origins of segmental arteries apart from the variations in origin and presence of accessory renal arteries have also been reported and must be identified on angiograms to avoid incomplete/erroneous embolization.[11] Portion of the renal parenchyma supplied by the segmental artery can be isolated and managed independently without affecting the other segments if embolization is done super-selectively engaging the segmental branches. Additionally, review of preoperative CT angiogram and use of intraoperative cone beam CT can help in identifying bleeding sites and can help in isolating the involved segments.[12]

With a wide variety of embolic agents available currently, preferred agent for management of different types of hemorrhage is indicated in [Table 2].[13] [14] Endoluminal stent-graft (covered stent) can be used to isolate the pseudoaneurysm and percutaneous USG-guided thrombin/NBCA injection can be attempted in a failed endovascular rescue.[15]

Table 2

Preferred embolic agent for the management of various causes of hemorrhage

Type of hemorrhage

Angiographic finding

Choice of embolizing agent

Pseudoaneurysm

Contrast filling of an irregular outpouching in communication with vessel lumen

Coils

Pseudoaneurysm with active extravasation

Contrast filling of an irregular outpouching in communication with vessel lumen associated with brisk contrast extravasation

Coils and/or NBCA (glue)

Arteriovenous or arteriocalyceal fistula

Early filling of vein/calyx adjacent to the contrast-opacified artery and could be associated with a pseudoaneurysm

NBCA (glue)

Abbreviation: NBCA, n-butyl cyanoacrylate.


Studies have dismissed any apprehensions of renal artery embolization causing renal function failure and have shown to cause no long-term adverse effect on the renal function and blood pressure control.[16]

In conclusion, development of pseudoaneurysms post-RPN is not an unknown entity but careful evaluation of preoperative imaging, multidisciplinary team meetings, accurate identification of origin of hemorrhage/pseudoaneurysm, and super-selective segmental approach to endovascular management would result in preserving as much as functional renal parenchyma as well as rescue the patient from fatal hemorrhagic complication.


#
#

Conflict of Interest

None declared.

  • References

  • 1 Connor J, Doppalapudi SK, Wajswol E. et al. Postoperative complications after robotic partial nephrectomy. J Endourol 2020; 34 (01) 42-47
  • 2 Verges DP, Margules A, Weprin S, Ferenczi B, Lallas CD. Delayed renal artery pseudoaneurysm after robotic partial nephrectomy. J Robot Surg 2017; 11 (02) 275-277
  • 3 Kutikov A, Uzzo RG. The R.E.N.A.L. nephrometry score: a comprehensive standardized system for quantitating renal tumor size, location and depth. J Urol 2009; 182 (03) 844-853
  • 4 Netsch C, Brüning R, Bach T, Gross AJ. Management of renal artery pseudoaneurysm after partial nephrectomy. World J Urol 2010; 28 (04) 519-524
  • 5 Yamashita S, Kawabata H, Deguchi R. et al. Natural history of asymptomatic pseudoaneurysm soon after robot-assisted partial nephrectomy: single-center prospective study. Urology 2021; 148 (148) 145-150
  • 6 Chavali JSS, Bertolo R, Kara O. et al. Renal arterial pseudoaneurysm after partial nephrectomy: literature review and single-center analysis of predictive factors and renal functional outcomes. J Laparoendosc Adv Surg Tech A 2019; 29 (01) 45-50
  • 7 Delto JC, Chang P, Hyde S, McAnally K, Crociani C, Wagner AA. Reducing pseudoaneurysm and urine leak after robotic partial nephrectomy: results using the early unclamping technique. Urology 2019; 132: 130-135
  • 8 Tohi Y, Murata S, Makita N. et al. Absence of asymptomatic unruptured renal artery pseudoaneurysm on contrast-enhanced computed tomography after robot-assisted partial nephrectomy without parenchymal renorrhaphy. Asian J Urol 2020; 7 (01) 24-28
  • 9 Singh D, Gill IS. Renal artery pseudoaneurysm following laparoscopic partial nephrectomy. J Urol 2005; 174 (06) 2256-2259
  • 10 Jeon CH, Seong NJ, Yoon CJ, Byun SS, Lee SE. Clinical results of renal artery embolization to control postoperative hemorrhage after partial nephrectomy. Acta Radiol Open 2016; 5 (08) 2058460116655833
  • 11 Rani N, Singh S, Dhar P, Kumar R. Surgical importance of arterial segments of human kidneys: an angiography and corrosion cast study. J Clin Diagn Res 2014; 8 (03) 1-3
  • 12 Grosse U, Syha R, Ketelsen D. et al. Cone beam computed tomography improves the detection of injured vessels and involved vascular territories in patients with bleeding of uncertain origin. Br J Radio 2018; 91 (1088): 20170562
  • 13 Chiramel GK, Keshava SN, Moses V, Kekre N, Tamilarasi V, Devasia A. Clinical outcomes of endovascularly managed iatrogenic renal hemorrhages. Indian J Radiol Imaging 2015; 25 (04) 380-390
  • 14 Wilkins LR, All J, Angle FJ. Transcatheter Embolization for Trauma of the Pelvis. Endovascular today. 2014 :60–67. Accessed December 17, 2021: https://evtoday.com/articles/2014-sept/transcatheter-embolization-for-trauma-of-the-pelvis
  • 15 NEA Saad, Wael ESaad, Mark GDavies, David LWaldman, Patrick JFultz, Deborah JRubens. Pseudoaneurysms and the role of minimally invasive techniques in their management. Radiographics 2005; 25 (Suppl. 01) S173-S189
  • 16 Collins CS, Eggert CH, Stanson AJ, Garovic VD. Long-term follow-up of renal function and blood pressure after selective renal arterial embolization. Perspect Vasc Surg Endovasc Ther 2010; 22 (04) 254-260

Address for correspondence

Nagateja Bonala, MD
Department of Interventional Radiology, HCG Hospital
Bengaluru, Karnataka 560027
India   

Publication History

Article published online:
11 January 2022

© 2022. Indian Society of Vascular and Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

  • References

  • 1 Connor J, Doppalapudi SK, Wajswol E. et al. Postoperative complications after robotic partial nephrectomy. J Endourol 2020; 34 (01) 42-47
  • 2 Verges DP, Margules A, Weprin S, Ferenczi B, Lallas CD. Delayed renal artery pseudoaneurysm after robotic partial nephrectomy. J Robot Surg 2017; 11 (02) 275-277
  • 3 Kutikov A, Uzzo RG. The R.E.N.A.L. nephrometry score: a comprehensive standardized system for quantitating renal tumor size, location and depth. J Urol 2009; 182 (03) 844-853
  • 4 Netsch C, Brüning R, Bach T, Gross AJ. Management of renal artery pseudoaneurysm after partial nephrectomy. World J Urol 2010; 28 (04) 519-524
  • 5 Yamashita S, Kawabata H, Deguchi R. et al. Natural history of asymptomatic pseudoaneurysm soon after robot-assisted partial nephrectomy: single-center prospective study. Urology 2021; 148 (148) 145-150
  • 6 Chavali JSS, Bertolo R, Kara O. et al. Renal arterial pseudoaneurysm after partial nephrectomy: literature review and single-center analysis of predictive factors and renal functional outcomes. J Laparoendosc Adv Surg Tech A 2019; 29 (01) 45-50
  • 7 Delto JC, Chang P, Hyde S, McAnally K, Crociani C, Wagner AA. Reducing pseudoaneurysm and urine leak after robotic partial nephrectomy: results using the early unclamping technique. Urology 2019; 132: 130-135
  • 8 Tohi Y, Murata S, Makita N. et al. Absence of asymptomatic unruptured renal artery pseudoaneurysm on contrast-enhanced computed tomography after robot-assisted partial nephrectomy without parenchymal renorrhaphy. Asian J Urol 2020; 7 (01) 24-28
  • 9 Singh D, Gill IS. Renal artery pseudoaneurysm following laparoscopic partial nephrectomy. J Urol 2005; 174 (06) 2256-2259
  • 10 Jeon CH, Seong NJ, Yoon CJ, Byun SS, Lee SE. Clinical results of renal artery embolization to control postoperative hemorrhage after partial nephrectomy. Acta Radiol Open 2016; 5 (08) 2058460116655833
  • 11 Rani N, Singh S, Dhar P, Kumar R. Surgical importance of arterial segments of human kidneys: an angiography and corrosion cast study. J Clin Diagn Res 2014; 8 (03) 1-3
  • 12 Grosse U, Syha R, Ketelsen D. et al. Cone beam computed tomography improves the detection of injured vessels and involved vascular territories in patients with bleeding of uncertain origin. Br J Radio 2018; 91 (1088): 20170562
  • 13 Chiramel GK, Keshava SN, Moses V, Kekre N, Tamilarasi V, Devasia A. Clinical outcomes of endovascularly managed iatrogenic renal hemorrhages. Indian J Radiol Imaging 2015; 25 (04) 380-390
  • 14 Wilkins LR, All J, Angle FJ. Transcatheter Embolization for Trauma of the Pelvis. Endovascular today. 2014 :60–67. Accessed December 17, 2021: https://evtoday.com/articles/2014-sept/transcatheter-embolization-for-trauma-of-the-pelvis
  • 15 NEA Saad, Wael ESaad, Mark GDavies, David LWaldman, Patrick JFultz, Deborah JRubens. Pseudoaneurysms and the role of minimally invasive techniques in their management. Radiographics 2005; 25 (Suppl. 01) S173-S189
  • 16 Collins CS, Eggert CH, Stanson AJ, Garovic VD. Long-term follow-up of renal function and blood pressure after selective renal arterial embolization. Perspect Vasc Surg Endovasc Ther 2010; 22 (04) 254-260

Zoom Image
Fig. 1 Catheter angiography (black arrow) and computed tomography volume-rendering technique image (white arrow) showing large saccular pseudoaneurysm in the interpolar region of right kidney. Angiography image post-super-selective embolization using microcoil (yellow arrow) shows no filling up of pseudoaneurysm.
Zoom Image
Fig. 2 Catheter angiography (black arrow) and computed tomography angiography image (white arrow) showing large saccular pseudoaneurysm in the interpolar region of left kidney. Angiography image post-super-selective embolization using microcoil (yellow arrow) shows absence in supply to the pseudoaneurysm.
Zoom Image
Fig. 3 Catheter angiography showing multiple large pseudoaneurysms (black arrows) in the lower and interpolar region of left kidney. Angiography image post-super-selective embolization using multiple microcoils (yellow arrows) shows arrest in filling up of pseudoaneurysm.
Zoom Image
Fig. 4 Catheter angiography shows large saccular pseudoaneurysms (black arrow) in the lower pole region of left kidney. Angiography image post-super-selective embolization using microcoils (yellow arrow) shows the desired result.