Background
Celiac disease is an autoimmune reaction to dietary gluten that affects the small
intestine in those with a genetic predisposition. The prevalence of celiac disease
has seen a significant increase over the last 10 years [1]
[2]
[3]. Unfortunately, some of these patients may be difficult to diagnose despite positive
serology due to the irregular and patchy histological distribution of abnormalities
in the small bowel affected by celiac disease, whose biopsies may be negative, unless
targeted biopsies are taken. Patients who partially avoid gluten before biopsies may
also have a patchy distribution of abnormalities. In addition, despite gluten avoidance,
it may make patients with persistent gastrointestinal symptoms difficult to assess
if they only have patchy recovery of the villi [4]
[5]
[6]
[7]. Several endoscopic features are well characterized with standard white light endoscopy
(WLE) such as reduction in the folds, mosaic or nodular pattern, scalloping and atrophy
of the villi with visible vessels [8]
[9]. However, controversial results have been reported concerning the accuracy of these
endoscopic markers to predict partial or patchy villous atrophy. The overall sensitivity
and specificity of these endoscopic findings in celiac disease vary from 6 % to 94 %
and from 83 % to 100 %, respectively [10]
[11]
[12]
[13]. Novel endoscopic techniques such as water immersion, dye and virtual chromoendoscopy,
high definition-zoom magnification, narrow-band imaging (NBI), Fujinon intelligent
chromoendoscopy (FICE), optical coherence tomography, probe confocal laser endomicroscopy,
and video capsule endoscopy have been developed to provide the ability to visualize
the architecture of the villi directly and more accurately [14]
[15]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[24]
[25]
[26]
[27]. The water immersion technique during normal endoscopy is very accurate for detection
of total villi atrophy but less accurate in detecting partial villous atrophy (PVA)
[17]
[19]. Recently, an Italian group has shown that chromoendoscopy with Indigo carmine and
endoscopic zoom magnification is also very accurate in difficult diagnoses of celiac
disease [25]. However, dye chromoendoscopy can be expensive and time consuming.
The newly developed i-SCAN technology is a post-processing imaging technology that
analyzes endoscopic images in real time without the use of dye. It can be performed
by simply pressing a button on the endoscope thereby allowing the endoscopist to alternate
between different setting modalities in real time [26]. One of the recent studies was performed by Cammarota et al. on the use of i-SCAN
in patients with celiac disease and it seems to be a potentially useful tool to anticipate
in vivo the presence of severe duodenal villi abnormality but it had lower accuracy
to detect and predict partial villous atrophy (PVA) or normal villi [27]. Hence, there is a need to study the combination of i-SCAN imaging at endoscopy
with the water immersion technique, which should be convenient to perform.
This study aimed to determine the performance of i-SCAN high definition endoscopy
in combination with the water immersion technique (i-SCAN-HDWI) in evaluating the
severity of histological damage in the duodenum in patients with celiac disease, especially
for those with a patchy distribution of villous damage.
Patients and methods
Study design
This was a retrospective cohort study performed at a single tertiary referral center.
The Conjoint Health Research Ethics Board of the University of Calgary and Calgary
Central Laboratory Services approved the study.
Patients
We studied 58 consecutive patients (46 women; median age 36.5 years, range 18 – 72
years) with positive anti-TTG IgA antibody who underwent i-SCAN-HDWI endoscopy (Pentax
EG-2985K) during the period from September 2011 to December 2013. These patients were
referred for upper endoscopy and biopsies. The patients were not on a gluten free
diet (GFD).
Endoscopic procedure – i-SCAN-HDWI
All endoscopic examinations were performed by a single gastroenterologist (MI) experienced
in using the i-SCAN technique. All procedures were performed under sedation. Retrospective
assessment of the i-SCAN images was performed by two endoscopists (MI and SG). All
esophagogastroduodenoscopy (EGD) procedures were performed with a Pentax EPK-I processor,
using HD-i-SCAN virtual chromoendoscopy in combination with the water immersion technique
(Pentax EC 2985K; Tokyo, Japan). The i-SCAN system is a new and emerging digital virtual
chromoendoscopy technique. It is a post-processing imaging technology that analyzes
the endoscopic image in real time. This consists of three types of algorithm: surface
enhancement (SE), contrast enhancement (CE), and tone enhancement (TE) and can provide
detailed analysis based on vessel (i-SCAN v), mucosal pattern (i-SCAN p), or surface
architecture (i-SCAN SE), and each of these algorithms can be selected by pressing
a pre-assigned button on the scope [26].
All patients underwent EGD with an initial careful endoscopic inspection of the duodenum
with WLE. Then i-SCAN-HDWI was performed in three steps, first i-SCAN-HDWI with i-SCAN
1 (i. e. high definition water immersion) and then with i-SCAN 2 – 3 (i-SCAN-HDWI).
The latter is considered to be i-SCAN-HDWI together ([Fig. 1], [Fig. 2], [Fig. 3]).
Fig. 1 a – c i-SCAN-HDWI using high definition alone or virtual chromoendoscopy in combination
with water immersion technique showed this transitional area of normal and patchy
atrophic villi. d Hematoxylin and eosin staining with magnification × 200 showed patchy atrophy of
the villi; Marsh modified 3b
Fig. 2 a WLE (standard definition) showed scalloping in the duodenum. b High definition-i-SCAN technique improved the characterization and the detailed atrophy
of the villi. c, d i-SCAN-HD virtual chromoendoscopy in combination with water immersion technique enhanced
and magnified the moderate atrophy of the villi
Fig. 3 a – c i-SCAN-HD alone or with virtual chromoendoscopy in combination with water immersion
technique showed severe atrophy of the villi and could differentiate single villi
in detail. d Hematoxylin and eosin staining with magnification × 50 revealed severe atrophy; Marsh
modified 3c
The water immersion endoscopic technique was performed during the examination of the
bulb and the second part of the duodenum. After removal of air from the lumen of the
duodenum by suction, about 100 – 150 mL of water was rapidly introduced with a pump
jet and all three i-SCAN sets were used in sequence, from set 1 to set 3, spending
an average time of 15 – 20 seconds for each single i-SCAN set. The different mucosal
patterns of the villi in the duodenum were assessed and graded first with the WLE
(standard definition) technique as normal (1), reduction in folds (2), mosaic pattern
(3), scalloping (4) and atrophy with visible vessels (5), and then with the i-SCAN-HDWI
endoscopic technique ( [Table 1]). The i-SCAN-HDWI was graded as normal, mild, moderate, patchy atrophy of villi,
or severe atrophy of villi ( [Table 2]).
Table 1
White light standard endoscopic classification.
|
Normal villi
|
|
Reduction of the fold
|
|
Mosaic pattern
|
|
Scalloping
|
|
Atrophy with visible vessels
|
Table 2
i-SCAN-HDWI endoscopic classification.
|
Normal villi
|
Arranged as regular carpet of fingertips
|
|
Mild atrophy of villi
|
Irregular shape and arrangement and shortened villi
|
|
Moderate atrophy of villi
|
Very shortened but still detectable villi
|
|
Patchy atrophy of villi
|
Patchy areas of flattened villi within normal finger-shaped arrangement
|
|
Severe atrophy of villi
|
Completely flat duodenal mucosa with no identifiable villi
|
The retrospective assessment of six high quality i-SCAN-WDWI endoscopic images in
the duodenum was performed by two endoscopists (MI, SG) and the inter-observer agreement
was calculated (Kappa agreement statistics).
Histological assessment
A comprehensive histological assessment was performed by one gastrointestinal histopathologist
(XG) who was unaware of the endoscopic findings or grading. Four i-SCAN-targeted biopsies
were taken from the second part of the duodenum and two from the bulb of the duodenum.
The histologic changes in the duodenal biopsies taken from the corresponding duodenal
regions were graded using Marsh’s classification as revised by Oberhuber et al. [28] ([Table 3]). The histological score categorized the severity of celiac disease as Marsh 1,
Marsh 2, or Marsh 3A-C based on the degree of villous blunting, number of intraepithelial
lymphocytes, and volume of deep crypts of duodenal mucosa. The key for Marsh’s score
for analysis was defined as 1 – normal, 2 – Marsh 1, 3 – Marsh 2, 4 – Marsh 3A, 5 – Marsh
3B, 6 – Marsh 3C.
Table 3
Modified Marsh histological classification.
|
Marsh Type
|
IEL/100 enterocytes
|
Crypt hyperplasia
|
Villi
|
|
0
|
< 40
|
Normal
|
Normal
|
|
1
|
> 40
|
Normal
|
Normal
|
|
2
|
> 40
|
Increased
|
Normal
|
|
3a
|
> 40
|
Increased
|
Mild atrophy
|
|
3b
|
> 40
|
Increased
|
Marked atrophy
|
|
3c
|
> 40
|
Increased
|
Absent
|
IEL/100 enterocytes, intraepithelial lymphocytes per 100 enterocytes.
Statistical analysis
The correlation between histology scores and endoscopy scores used in the study was
calculated using the non-parametric Spearman’s correlation approach. The sensitivity,
specificity, and accuracy values for the endoscopic i-SCAN-based investigation in
predicting histological findings were estimated. Confidence intervals at 95 % were
calculated.
Two endoscopists (MI, SG) analyzed six high quality anonymized i-SCAN images. These
images represented the bulb and the second portion of the duodenum of the same patient.
The images were anonymous and while MI had performed the procedures, the anonymous
nature of the images and the fact that the second rater SG was blinded ensured robustness
of agreement. The interobserver and intraobserver agreement was calculated using Cohen
Kappa statistics. Interpretation of Kappa values was done according to evaluation
of Cohen’s Kappa with > 0.75 indicating good agreement, 0.4 – 0.75 indicating fair
to good agreement, and < 0.4 indicating poor agreement. The statistical analyses were
carried out using the SPSS statistical software package v.22 (IBM, Armonk, New York,
United States).
Results
Patient characteristics
In total, 58 consecutive patient (46 women; median age 36.5 years, range 18 – 72 years)
with positive anti-endomysial antibodies or anti-transglutaminase antibodies and with
a clinical history consistent with celiac disease were enrolled in the study when
they were referred for EGD. Clinical history included symptoms and signs of diarrhea,
abdominal pain, bloating and distension, iron deficiency anemia, and weight loss.
Endoscopic findings on i-SCAN-HDWI
Of the 58 patients, Marsh grades were as follows: normal (n = 1), Marsh 1 (n = 7),
Marsh 2 (n = 7), Marsh 3A (n = 14), Marsh 3B (n = 12), Marsh 3C (n = 17) ([Table 3]).
The seven patients with Marsh grade 1 were not included in the statistical analysis
to determine the correlation with WLE and with i-SCAN-HDWI, as the mucosa appeared
normal.
A significant and good correlation was demonstrated between endoscopic grade using
i-SCAN-HDWI and modified Marsh histologic grade (r = 0.732; P < 0.00001) ( [Table 4]). The correlation between standard WLE grade and Marsh histologic grade was poorer
than with i-SCAN-HDWI (r = 0.31; P = 0.01).
Table 4
Endoscopic findings for HD-i-SCAN with water immersion and agreement with histological
Marsh grade (one patient was negative for celiac disease).
|
i-SCAN-HDWI
|
Marsh 2
|
Marsh 3A
|
Marsh 3b
|
Marsh 3c
|
|
Normal villi
|
1
|
–
|
–
|
–
|
|
Mild atrophy of villi
|
2
|
–
|
1
|
–
|
|
Moderate atrophy of villi
|
3
|
9
|
3
|
5
|
|
Patchy atrophy of villi
|
3
|
4
|
1
|
1
|
|
Severe atrophy of villi
|
–
|
–
|
6
|
11
|
Correlation between endoscopic grade and histologic grade was r = 0.734 using Spearman correlation.
The sensitivity of i-SCAN-HDWI was 96 % (95 %CI: 85 – 99 %) and the specificity was
63 % (95 %CI: 26 – 90 %) in diagnosing abnormal biopsy consistent with celiac disease
(Marsh 2, 3a, 3b, 3c). [If Marsh grade 1 was included, the sensitivity was 88 % (95 %CI
76 – 95 %)]. The accuracy of i-SCAN-HDWI to predict histology was 100 % (51 out of
51) if Marsh grade 1 was excluded.
The sensitivity of WLE (standard definition) was 78 % (95 %CI 64 – 88 %) and specificity
was 50 % (95 %CI 17 – 83 %) in diagnosing abnormal biopsy consistent with celiac disease
(Marsh 2, 3a, 3b, 3c). [If Marsh grade 1 was included, the sensitivity was 74 % (95 %CI
60 – 84 %)]. The accuracy of WLE (standard definition) to predict histology was 72 %.
Of the nine patients with patchy atrophy of the villi on i-SCAN-HDWI, five showed
normal endoscopic findings on WLE (standard definition) (55.6 %). Of the six patients
with mild atrophy of the villi on i-SCAN-HDWI, two patients had normal endoscopic
findings on WLE (standard definition) (33.3 %). Of the 20 patients with moderate atrophy
of the villi on i-SCAN-HDWI, only two patients had normal endoscopic finding on WLE
(standard definition) (10 %).
The interobserver agreement of i-SCAN-HDWI between the two endoscopists was calculated
and the Kappa statistic was 0.86 (95 %CI 0.72 – 0.90) and the strength of observation
was considered to be ‘very good’.
Discussion
The current study showed that high definition i-SCAN in combination with the water
immersion endoscopic technique has a good accuracy in the diagnosis of patchy atrophy
of villi in patients with celiac disease. Endoscopy with histological assessment of
villous atrophy of the duodenum still represents the gold standard for diagnosis of
celiac disease.
However, WLE with random biopsies in the duodenum has not been shown to have great
accuracy in the diagnosis of celiac disease [10]
[13]. Our study has shown a poorer correlation between WLE grade and Marsh histologic
grade in the diagnosis of celiac disease (r = 0.31; P = 0.01) compared with the i-SCAN-HDWI endoscopic technique. In addition, a more recent
paper by Barada et al. has indicated that standard endoscopic findings were related
to a significant rate of underdiagnosis of celiac disease [13].
Novel emerging endoscopic techniques such as water immersion techniques, chromoendoscopy,
and optical digital enhancement virtual chromoendoscopy have been developed to better
characterize in detail the vascular and surface architecture of the gastrointestinal
tract. These endoscopic techniques have been found to be a useful adjunctive tool
to increase the diagnostic yield of celiac disease, especially in the presence of
patchy villous atrophy [14]
[27]. All procedures were performed under sedation, and the instillation of 100 – 150 mL
of water was not associated with any episode of bronchial aspiration. The fluid was
rapidly aspirated after detailed inspection.
In our study, we have found a significant correlation between endoscopic grade using
i-SCAN-HDWI and modified Marsh histologic grade (r = 0.732; P < 0.00001). Correlation coefficients were used to indicate a linear relationship
between the different methods but these did not indicate agreement.
The strength of agreement between the two i-SCAN readers (MI and SG) was considered
to be very good. The two endoscopists have performed more than a thousand i-SCAN procedures.
Cammarota and colleagues [18], pioneers of the water immersion endoscopic technique, have demonstrated that the
sensitivity, specificity, and positive and negative predictive values of the immersion-based
duodenal investigation in predicting areas of duodenal villous atrophy were always
100 %. In contrast, the water immersion technique alone was less accurate in distinguishing
partial villous atrophy (PVA) (72 % sensitivity and 97 % specificity values) from
a normal condition of the villi (97 % sensitivity and 85 % specificity).
The same result has been confirmed by Cammarota et al. using i-SCAN techniques alone
with high accuracy (100 %) in the detection of marked villous atrophy patterns but
has shown lower accuracy in characterizing PVA or normal villous patterns [27].
It is becoming recognized that patients with celiac disease (especially when on a
partial gluten free diet) may have endoscopic irregular or patchy distribution of
gluten-sensitive enteropathy, which can be difficult to detect by WLE (standard definition).
Moreover, some patients with celiac disease, especially those with a patchy distribution
of atrophy of the small bowel, may have negative celiac disease-specific serology
and positive HLA DQ2-DQ8, but this does not completely exclude the diagnosis of celiac
disease. This, unfortunately, could cause underdiagnosis, especially when random specimens
of apparently normal mucosa are taken during endoscopy [3]
[14].
High magnification endoscopy with virtual or dye chromoendoscopy has been shown to
improve the detection and diagnosis of partial villous atrophy of the villi compared
with WLE (standard definition) [15]
[16]. Iovino et al. have demonstrated that chromoendoscopy with indigo carmine and endoscopic
zoom-magnification chromo-zoom endoscopy have high accuracy for cases of difficult
diagnosis of celiac disease, but only in untreated patients with celiac disease [25].
In our study, we have combined i-SCAN high definition endoscopy with the water immersion
technique (i-SCAN-HDWI) to determine whether both techniques could better magnify
the architecture of the villi and improve the accuracy and diagnostic yield of patchy
atrophy of the villi in the duodenum ([Fig. 1], [Fig. 2], [Fig. 3]). We have also confirmed the good sensitivity of i-SCAN-HDWI – 96 % (95 %CI: 85 – 99 %)
in diagnosing abnormal biopsy consistent with celiac disease (Marsh 2, 3a, 3b, 3c)
and the good accuracy of i-SCAN-HDWI to predict histology. It was interesting that,
of the nine (15.5 %) patients with patchy atrophy of the villi, six showed normal
endoscopic findings on WLE but all of them had positive endoscopic findings on i-SCAN-HDWI.
In future, analysis of endoscopic images obtained directly or via wireless capsule
using computerized image analysis may help to distinguish various degrees of villous
atrophy. Ciaccio and colleagues have analyzed endoscopic images and have recently
tested a quantitative technique for the evaluation of villous atrophy and of motility
in endoscopic images [29]
[30]; however, histological diagnosis still represents the gold standard for celiac diagnosis.
Limitations of this study include the fact that it is a retrospective study, and that
it is a single center study. We did not use the water immersion technique in isolation
with WLE, or in isolation with the i-SCAN technique. However, the study is strengthened
by the fact that it is the first to assess patients with celiac disease using HD i-SCAN
in combination with the water immersion technique, which improved the diagnosis of
patchy atrophy of the villi in celiac disease. It will require long-term prospective
studies with a larger number of patients to validate these findings. We feel that,
in this era, these electronic image enhancement techniques can provide a much clearer
characterization of the vascular pattern and surface architecture of the villi and
may be an important adjunctive tool, especially to recognize the patchy distribution
of villi in patients who were serologically positive or negative for celiac disease.
The water immersion and i-SCAN techniques can be easily and regularly performed in
the duodenum by endoscopists during routine EGD. This procedure is simple, feasible,
and can accurately detect atrophy of the villi. However, the learning curve for this
technique was not evaluated as this was not an aim in this study.
Conclusions
High definition-i-SCAN endoscopy with the water immersion technique (i-SCAN-HDWI)
provides the ability to enhance the vascular and mucosal pattern and to visualize
duodenal villi directly and more accurately. These endoscopic techniques in combination
can improve the characterization of patchy atrophy of the villi and differentiate
Marsh histological grades. They can help in directing and targeting duodenal biopsies
and improve their diagnostic yield in celiac patients, especially for those with difficult
diagnoses and patchy distribution of villous damage. However, large and multinational
validation studies are required to confirm the ability of these techniques for widespread
use in daily clinical practice and to establish their learning curve. It is important
to be aware of the limitations of the usual white-light endoscopy technique in recognizing
these subtle abnormalities.