CC BY-NC-ND 4.0 · Journal of Clinical Interventional Radiology ISVIR 2023; 07(03): 172-178
DOI: 10.1055/s-0043-1768040
Original Article

Safety and Efficacy of Vacuum-Assisted Breast Biopsies under Ultrasound and Stereotactic Guidance

Palak Bhavesh Thakkar Popat
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Aashna Karbhari
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Nitin Shetty
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Kunal Gala
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Purvi Haria
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Aparna Katdare
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Sonal Chauhan
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Vani Parmar
2   Department of Surgical Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Nita Nair
2   Department of Surgical Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Shalaka Joshi
2   Department of Surgical Oncology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Sangeeta Desai
3   Department of Pathology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Tanuja Shet
3   Department of Pathology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Asawari Patil
3   Department of Pathology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Ayushi Sahay
3   Department of Pathology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Meenakshi Thakur
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Rajendra Badwe
4   Department of Surgical Oncology, Tata Memorial Centre, Homi Bhabha National Institute, Tata Memorial Hospital, Mumbai, Maharashtra, India
,
Suyash Kulkarni
1   Department of Radiology, Tata Memorial Hospital, Mumbai, Maharashtra, India
› Author Affiliations
Funding None.
 

Abstract

Purpose To evaluate the safety and efficacy of vacuum-assisted breast biopsy (VABB) under ultrasound and stereotactic guidance.

Methods This institutionally approved retrospective analysis comprised 60 females who underwent VABB under ultrasound and stereotactic guidance. Technical success and adverse events were analyzed as per the Society of Interventional Radiology standards. Pain score was recorded as per the visual analog scale.

Results Technical success was 100% with high specificity (100%), sensitivity (96%), negative predictive value 97%, and accuracy of 98%. Ductal carcinoma in situ underestimation rate was 4%. No major complications were encountered, and minor complication of postprocedural hematoma did not require intervention. Procedure was well tolerated with majority patients experiencing mild pain.

Conclusion VABB under ultrasound and stereotactic guidance is a safe and effective method for sampling breast abnormalities.


#

Introduction

Breast cancer incidence has progressively increased over the years, becoming the leading cause of cancer in females worldwide.[1] Breast abnormalities are currently being assessed using the “triple test,” a comprehensive approach encompassing clinical breast examination, imaging, and histopathological correlation. Despite a multipronged approach of various breast imaging modalities, lesions deemed as indeterminate or suspicious will still require a histological correlation, thereby rendering surgical excision as the gold standard for breast abnormalities. However, the associated cost, psychological burden, and duration of hospital stay for open surgical biopsies are high. As a result, since decades, less invasive alternative techniques such as “core needle biopsy” (CNB) whether image guided or nonguided, has been incorporated into standard evaluation of breast lesions requiring histological evaluation.[2] [3] [4] [5] [6] CNB may be plagued by histologic underestimation and false-negative diagnoses, especially in smaller and complex lesions.[7] [8] [9] These caveats are further reinforced by the need for larger tissue volume imperative for complete histopathological assessment, including analysis of molecular subtype, tumor grade, receptor status, and genetic profile to guide further management. As redressal, vacuum-assisted breast biopsy (VABB), a form of CNB powered by vacuum suction, allowing contiguous retrieval of larger core samples, without the need for needle reinsertion with a collateral benefit of vacuum evacuation of postbiopsy blood products was developed.[10] [11] [12] First introduced in 1995, VABB has been accepted as an alternative method to CNB to diagnose breast lesions with high sensitivity and specificity.[13] [14] [15] [16] Hematoma formation is the most commonly associated complication with this sampling technique.[17]

This study is a retrospective analysis of all consecutive, VABBs from March 2021 to February 2022 at a tertiary cancer care center to evaluate safety and efficacy of this sampling technique with respect to needle gauge and guiding modality.


#

Materials and Methods

Ethics Committee approval of a retrospective study with waiver of consent was granted by the Institutional Review Board. Patient demographics and lesion data are shown in [Table 1].

Table 1

Demographic and lesion data

Patients

60

Age (y), mean (range)

47 (22–70)

Gender

Female (n = 60)

Location in breast

 Upper outer

24

 Upper inner

11

 Central, diffuse

13, 3

 Lower outer

7

 Lower inner

2

Patient Selection

The morphology of the findings during mammography (MG) and/or ultrasonography (US) were interpreted and categorized as per the American College of Radiology Breast Imaging Reporting and Data System (ACR BI-RADS) version 5.0.[18] According to standard lexicon recommendations, biopsy was considered for all categories 4 and 5 lesions, while for category 3 lesions, biopsy was performed at the discretion of the referring physician. Subcentimeter-sized lesions and those with a complex morphology (aggregation of ducts; initial nonrepresentative or discordant previous biopsy) were planned for VABB. The decision of US versus stereotactic (MG) guidance was case specific, considering the lesion's size, microcalcifications, and location in the breast. If a lesion was detected by both MG and US, then, for noncalcific lesions, ultrasound VABB (U-VABB) was preferred due to greater flexibility in needle placement, maneuvering, and visibility of the procedure performed. For lesions containing microcalcifications, and visible on US, the latter was still preferred for sampling a sonographically visible (possibly invasive) component followed by specimen mammogram ([Fig. 1]). MG-only-detected suspicious microcalcifications, asymmetry, and architectural distortion were targeted by stereotactic VABB (S-VABB). None of the patients were on anticoagulants/antiplatelets and none of the patients were sedated. Patient demographics and lesion distribution are summarized in [Table 1].

Zoom Image
Fig. 1 A 46-year-old woman with a history of nipple discharge from right breast underwent mammography. (A) Craniocaudal (CC) view showed regional distribution of amorphous calcification with associated density. Targeted ultrasound revealed an ill-defined hypoechoic lesion with multiple echogenic foci representative of microcalcifications (not shown). (B) Ultrasound image showing microcalcification (arrow) within the needle trough. (C) CC view showing post-VABB changes and clip marker in situ. Histopathology revealed fibrocystic change, apocrine metaplasia, duct hyperplasia without atypia, and microcalcifications. Patient is on routine surveillance.

#

Equipment

US was performed using a linear transducer (LA3–16A) (EVO RS80; Samsung Healthcare, Seoul, South Korea), and MG was performed on Senographe Pristina (GE Healthcare, Milwaukee, Wisconsin, United States) with an integrated stereotaxy facility. 10G and 7G vacuum-assisted needle probes compatible with its dedicated vacuum device were used (EnCor Aspire; BARD, Murray Hill, New Jersey, United States) for performing the biopsies. Written informed consent was obtained from all patients.


#

Procedure

Patients were placed in the supine position for U-VABB, while for S-VABB, patients were comfortably seated upright. Biopsy track and skin was infiltrated with 2% lidocaine creating a wheal, followed by instillation of lidocaine–adrenaline (1:200,000) along the track and surrounding the lesion to minimize bleeding.

In U-VABB, needle probe was positioned either juxta-superior/inferior or within the lesion depending on its proximity to chest wall or skin, and its size, such that the needle trough is epicentered along the lesion ([Fig. 2]).

Zoom Image
Fig. 2 A 72-year-old woman, treated case of triple negative breast cancer 20 years ago, on routine follow-up. Mammography (MG) showed a faint new density in the inner aspect. A small 5-mm irregular hypoechoic lesion was seen on ultrasonography (US), and confirmed to represent the corresponding MG-detected lesion with a mammogram after placement of a (A) skin marker (triangle) and intralesional contrast instillation (B). US images showing (C) hypoechoic lesion (arrow) and the (D) needle along its inferior aspect (arrow head). Histopathology revealed invasive ductal carcinoma.

In S-VABB, needle position was confirmed before sample retrieval by acquiring an additional set of paired images after needle insertion, followed by sample acquisition. For lesions with microcalcifications, specimen radiographs were acquired before concluding the procedure to confirm their presence ([Fig. 3]).

Zoom Image
Fig. 3 A 45-year-old woman with a family history of breast cancer underwent screening mammography. (A) Biopsy planning craniocaudal view of left breast showed pleomorphic calcification in segmental distribution. (B) Needle at target site. (C) Specimen radiograph confirming microcalcification in biopsy cores. Histopathology revealed ductal carcinoma in situ, which was further confirmed on subsequent surgery.

Localizing marker (clip) was placed at the biopsy site in cases of near-complete excision or in cases where the target was a single group of microcalcifications.

Post-VABB, cold compression was applied longitudinally encompassing the site of incision, trajectory, and the lesion for ∼10 to 15 minutes until no oozing was observed, followed by antiseptic dressing, hematoma volume assessment, and application of an elastic compression bandage around the chest. Postprocedure hematoma volume was measured on US immediately postbiopsy (day 0), after 24 hours (day 1), and on the 7th to 10th day. Complications were categorized according to the “Society of Interventional Radiology” (SIR) adverse event classification system.[19] No literature could be found on volume of hematoma considered as significant in breast, and so for the purpose of this study, postprocedure hematoma volume of more than 20 mL was defined as significant. All patients were contacted via telephone on day 3 to inquire about local site discomfort, ooze, purulent discharge, and fever.


#

Analysis

Diagnostic yield (DY) was analyzed as per the SIR standards[20] where DY is defined as percentage of biopsies that result in a diagnosis. Histopathology of the final surgical specimen or biopsy sample in that order of preference was considered as the gold standard. Safety was evaluated by recording the “SIR-classified” complications as minor (A, B) or major (C, D, E, F).[19] Pain level was recorded using the visual analog scale (VAS) ranging from 0 (no pain) to 10 (worst pain experienced). Histologic underestimation was considered when “ductal carcinoma in situ” (DCIS) on VABB was upgraded to invasive carcinoma on surgical excision. Statistical analysis for postprocedure hematoma volume and its association with needle gauge (10G vs. 7G) or guiding modality (US vs. MG) was performed using the Mann–Whitney's U test and the results were considered statistically significant for p-value < 0.05. Statistical analysis was performed using SPSS (the Statistical Package for Social Sciences), IBM Corp, released 2012, IBM SPSS Statistics for Windows, Version 21.0. Armonk, New York, United States: IBM Corp, and RStudio, version 1.1463, RStudio Inc.


#
#

Results

Results are summarized in [Table 2]. Sixty patients underwent VABB between March 2021 and February 2022, of which one was a therapeutic excision (n = 1) on the patient's request ([Fig. 4]) and the rest (n = 59) were diagnostic. [Table 3] gives an overview of lesions categorized as per ACR BI-RADS and their percentage of malignancy on histopathology, with most lesions classified as ACR BI-RADS category 4. Histopathology reports of all patients confirmed 100% DY with one case of underestimation (4%) where U-VABB yielded DCIS; however, invasive ductal carcinoma was found on surgery. In terms of safety, no major complications, requiring hospital stay or intervention were encountered. Minor complication of postprocedural hematoma not requiring nominal therapy or intervention was observed in 42 cases, while 18 patients showed no measurable hematoma immediately after the procedure or on subsequent follow-up imaging. Average postprocedure hematoma volume on day 0 was ∼1.8 mL (0.6–2.5) in S-VABB, 2 mL (1–3) in U-VABB, 1.6 mL (0.9–3) with 10G needle, and 2 mL (1.3–3) with 7G needle ([Figs. 5] and [6]). Of the 42 cases, hematoma volumes were nonmeasurable by day 7 in 31 cases, and there was no significant correlation between postprocedure hematoma volume and needle gauge (p = 0.2) or imaging guiding modality (p = 0.4). Procedure was well tolerated with most patients (62%) experiencing only mild pain ([Table 4]).

Zoom Image
Fig. 4 A 42-year-old woman with clinically palpable right breast lump. Ultrasonography revealed a well-defined oval hypoechoic mass (solid arrow). Vacuum-assisted breast biopsy (VABB) was performed with intent of excision. (A) VABB needle probe is seen along the inferior aspect of the mass (arrowheads). (B) Gradual decrease in lesion size (split-end arrow) with visible cutting edge (triangle). Histopathology confirmed cellular fibroadenoma. Patient is on follow-up.
Zoom Image
Fig. 5 Evolution of hematoma in relation to vacuum-assisted breast biopsy guiding modality (stereotactic guided vs. ultrasound guided).
Zoom Image
Fig. 6 Evolution of hematoma in relation to vacuum-assisted breast biopsy needle gauge (10G vs. 7G).
Table 2

Results

Variable

Value

95% confidence interval

Accuracy

98.3%

91.06–99.96%

Sensitivity

96%

79.65–99.90%

Specificity

100%

90–100%

Negative predictive value

97%

83.7–99.6%

Table 3

Lesion characteristics

ACR BI-RADS category

No. of VABB (%) malignant

3

1 (2)

Nil

4a

27 (45)

6/27 (22%)

4b

16 (27)

7/16 (44%)

4c

11 (18)

8/11 (73%)

5

5 (8)

4/5 (80%)

Biopsy histology

 Benign

35 (58)

 Malignant

25 (42)

 Underestimation (%)

4%

Abbreviations: ACR BI-RADS, American College of Radiology Breast Imaging Reporting and Data System; VABB, vacuum-assisted breast biopsy.


Table 4

Pain scores using the visual analog scale

Pain score

Number of VABB (%)

Mild (1–3)

37 (62)

Moderate (4–6)

21 (35)

Severe (7–9)

2 (3)

No pain, worst pain experienced

0

Abbreviation: VABB, vacuum-assisted breast biopsy.



#

Discussion

The current study affirms the high accuracy of VABB, particularly in small and indeterminate lesions, with high specificity of 100%, sensitivity of 96%, negative predictive value (NPV) of 97%, and accuracy of 98%. These results are in line with meta-analysis by Yu et al[13] estimating specificity of 100% and sensitivity of 98% including larger studies like those by Penco et al (n = 4,086) (sensitivity = 99.7–100%)[14] and Kettritz et al (n = 2,874) (sensitivity, NPV > 99%).[15]

The DCIS underestimation rate of VABB (4%) in this study was lower than that seen in previous studies such as Tsai et al (16.7%), Penco et al (17.9%), Cassano et al (16.7%), and Suh et al (16.1%) and the published underestimation rates of CNB (20–55%),[8] [14] [15] [16] [21] [22] [23] thus reiterating the benefits of VABB over CNB. VABB successfully addressed all cases of repeat biopsies initially sampled using a 14G CNB automated gun and two cases of CNB underestimation; hence, our findings are in tandem with existing literature suggesting lower sampling error and underestimation in VABB.

VABB specimen histopathology revealed 42% lesions as malignant, and 58% as benign, in concordance with published literature reflecting appropriate patient selection as per BI-RADS categorization[14] [15] [24] [25] [26] [27]; 63% of patients in this study had lesions measuring <10 mm which was comparable to study cohorts of Kettritz et al (58%) and Penco et al (46%) conforming to appropriate patient selection for VABB.

No major complications were encountered in this study which is similar to findings of various previous studies.[28] [29] [30] [31] Like Park and Hong, the most commonly associated adverse event was found to be hematoma formation, which was manageable by manual compression and with all except one case having postprocedural hematoma volume <5 mL, which also regressed by the seventh day.[32] Simon et al reported prolonged post-VABB bleeding (>10 minutes) in 7% of patients and vasovagal response in 1% of the procedures,[33] Johnson et al[34] reported infections requiring intervention in 2% cases and Kettritz et al reported complications in 1.4% procedures including hematomas >4 cm (n = 25), persistent bleeding (n = 4), vasovagal episodes (n = 5), seizure (n = 1), and inflammation (n = 5).[15] One of the reasons for smaller hematoma volumes observed could be meticulous avoidance of traversing vessels by Doppler evaluation of skin site entry, trajectory, up to the lesion, on U-VABB, and repositioning or rolling of breast in case of overlapping coursing vessels in S-VABB. No statistically significant association between complications and needle gauge or guiding modality was observed in this study, similar to findings published by Burbank et al. Alike Bohan et al's experience (55%), most patients in this study reported mild pain (62%).[35] Mean pain score was 3 which was close to findings of Seely et al (3.1), pointing to the good overall tolerance of VABB.[36]

Retrospective design of this study, small sample size, and limited follow-up are limitations of this study. However, VABB holds maximum potential in carefully selected breast lesions considering the balance between associated cost (higher than CNB) and clinical impact.


#

Conclusion

VABB is a promising means of targeting indeterminate or suspicious findings on MG and ultrasound, and VABB, performed with adequate quality assurance, is safe and efficacious. Side effects are minimal and hematoma formation is unrelated to gauge of needle and imaging modality of guidance.


#
#

Conflict of Interest

None declared.

Ethical Approval

This was an ethics approved study for analysis but being retrospective, formal consent was not required.


  • References

  • 1 Sung H, Ferlay J, Siegel RL. et al. Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 2021; 71 (03) 209-249
  • 2 Parker SH, Jobe WE, Dennis MA. et al. US-guided automated large-core breast biopsy. Radiology 1993; 187 (02) 507-511
  • 3 Liberman L, Feng TL, Dershaw DD, Morris EA, Abramson AF. US-guided core breast biopsy: use and cost-effectiveness. Radiology 1998; 208 (03) 717-723
  • 4 Smith DN, Rosenfield Darling ML, Meyer JE. et al. The utility of ultrasonographically guided large-core needle biopsy: results from 500 consecutive breast biopsies. J Ultrasound Med 2001; 20 (01) 43-49
  • 5 Fishman JE, Milikowski C, Ramsinghani R, Velasquez MV, Aviram G. US-guided core-needle biopsy of the breast: how many specimens are necessary?. Radiology 2003; 226 (03) 779-782
  • 6 Fajardo LL, Pisano ED, Caudry DJ. et al; Radiologist Investigators of the Radiologic Diagnostic Oncology Group V. Stereotactic and sonographic large-core biopsy of nonpalpable breast lesions: results of the Radiologic Diagnostic Oncology Group V study. Acad Radiol 2004; 11 (03) 293-308
  • 7 Jackman RJ, Nowels KW, Rodriguez-Soto J, Marzoni Jr FA, Finkelstein SI, Shepard MJ. Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: false-negative and histologic underestimation rates after long-term follow-up. Radiology 1999; 210 (03) 799-805
  • 8 Darling ML, Smith DN, Lester SC. et al. Atypical ductal hyperplasia and ductal carcinoma in situ as revealed by large-core needle breast biopsy: results of surgical excision. AJR Am J Roentgenol 2000; 175 (05) 1341-1346
  • 9 Han BK, Choe YH, Ko YH, Nam SJ, Kim JH, Yang JH. Stereotactic core-needle biopsy of non-mass calcifications: outcome and accuracy at long-term follow-up. Korean J Radiol 2003; 4 (04) 217-223
  • 10 Burbank F, Parker SH, Fogarty TJ. Stereotactic breast biopsy: improved tissue harvesting with the Mammotome. Am Surg 1996; 62 (09) 738-744
  • 11 Berg WA, Krebs TL, Campassi C, Magder LS, Sun CC. Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model. Radiology 1997; 205 (01) 203-208
  • 12 Parker SH, Klaus AJ, McWey PJ. et al. Sonographically guided directional vacuum-assisted breast biopsy using a handheld device. AJR Am J Roentgenol 2001; 177 (02) 405-408
  • 13 Yu YH, Liang C, Yuan XZ. Diagnostic value of vacuum-assisted breast biopsy for breast carcinoma: a meta-analysis and systematic review. Breast Cancer Res Treat 2010; 120 (02) 469-479
  • 14 Penco S, Rizzo S, Bozzini AC. et al. Stereotactic vacuum-assisted breast biopsy is not a therapeutic procedure even when all mammographically found calcifications are removed: analysis of 4,086 procedures. AJR Am J Roentgenol 2010; 195 (05) 1255-1260
  • 15 Kettritz U, Rotter K, Schreer I. et al. Stereotactic vacuum-assisted breast biopsy in 2874 patients: a multicenter study. Cancer 2004; 100 (02) 245-251
  • 16 Tsai HY, Chao MF, Ou-Yang F. et al. Accuracy and outcomes of stereotactic vacuum-assisted breast biopsy for diagnosis and management of nonpalpable breast lesions. Kaohsiung J Med Sci 2019; 35 (10) 640-645
  • 17 Fu SM, Wang XM, Yin CY, Song H. Effectiveness of hemostasis with Foley catheter after vacuum-assisted breast biopsy. J Thorac Dis 2015; 7 (07) 1213-1220
  • 18 Reporting BI. Data System (BI-RADS). Reston (VA): American College of Radiology; 1998
  • 19 Khalilzadeh O, Baerlocher MO, Shyn PB. et al. Proposal of a new adverse event classification by the Society of Interventional Radiology Standards of Practice Committee. J Vasc Interv Radiol 2017; 28 (10) 1432-1437 .e3
  • 20 Sheth RA, Baerlocher MO, Connolly BL. et al. Society of Interventional Radiology quality improvement standards on percutaneous needle biopsy in adult and pediatric patients. Journal of vascular and interventional radiology. J Vasc Interv Radiol 2020; 31 (11) 1840-1848
  • 21 Cassano E, Urban LA, Pizzamiglio M. et al. Ultrasound-guided vacuum-assisted core breast biopsy: experience with 406 cases. Breast Cancer Res Treat 2007; 102 (01) 103-110
  • 22 Suh YJ, Kim MJ, Kim EK. et al. Comparison of the underestimation rate in cases with ductal carcinoma in situ at ultrasound-guided core biopsy: 14-gauge automated core-needle biopsy vs 8- or 11-gauge vacuum-assisted biopsy. Br J Radiol 2012; 85 (1016): e349-e356
  • 23 Schueller G, Schueller-Weidekamm C, Helbich TH. Accuracy of ultrasound-guided, large-core needle breast biopsy. Eur Radiol 2008; 18 (09) 1761-1773
  • 24 Ancona A, Caiffa L, Fazio V. Digital stereotactic breast microbiopsy with the mammotome: study of 122 cases [in Italian]. Radiol Med (Torino) 2001; 101 (05) 341-347
  • 25 Brem RF, Schoonjans JM, Sanow L, Gatewood OM. Reliability of histologic diagnosis of breast cancer with stereotactic vacuum-assisted biopsy. Am Surg 2001; 67 (04) 388-392
  • 26 Burak Jr WE, Owens KE, Tighe MB. et al. Vacuum-assisted stereotactic breast biopsy: histologic underestimation of malignant lesions. Arch Surg 2000; 135 (06) 700-703
  • 27 Lai JT, Burrowes P, MacGregor JH. Diagnostic accuracy of a stereotaxically guided vacuum-assisted large-core breast biopsy program in Canada. Can Assoc Radiol J 2001; 52 (04) 223-227
  • 28 Yelland A, Graham MD, Trott PA. et al. Diagnosing breast carcinoma in young women. BMJ 1991; 302 (6777): 618-620
  • 29 Bernik SF, Troob S, Ying BL. et al. Papillary lesions of the breast diagnosed by core needle biopsy: 71 cases with surgical follow-up. Am J Surg 2009; 197 (04) 473-478
  • 30 Burbank F. Mammographic findings after 14-gauge automated needle and 14-gauge directional, vacuum-assisted stereotactic breast biopsies. Radiology 1997; 204 (01) 153-156
  • 31 Tseng HS, Chen YL, Chen ST. et al. The management of papillary lesion of the breast by core needle biopsy. Eur J Surg Oncol 2009; 35 (01) 21-24
  • 32 Park HL, Hong J. Vacuum-assisted breast biopsy for breast cancer. Gland Surg 2014; 3 (02) 120-127
  • 33 Simon JR, Kalbhen CL, Cooper RA, Flisak ME. Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results. Radiology 2000; 215 (03) 694-697
  • 34 Johnson AT, Henry-Tillman RS, Smith LF. et al. Percutaneous excisional breast biopsy. Am J Surg 2002; 184 (06) 550-554 , discussion 554
  • 35 Bohan S, Ramli Hamid MT, Chan WY. et al. Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions. Sci Rep 2021; 11 (01) 129
  • 36 Seely JM, Hill F, Peddle S, Lau J. An evaluation of patient experience during percutaneous breast biopsy. Eur Radiol 2017; 27 (11) 4804-4811

Address for correspondence

Suyash Kulkarni, DMRD, DNB
Department of Radiology
Tata Memorial Hospital, E. Borges Road, Parel, Mumbai 400012, Maharashtra
India   

Publication History

Article published online:
12 June 2023

© 2023. Indian Society of Vascular and Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

  • References

  • 1 Sung H, Ferlay J, Siegel RL. et al. Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 2021; 71 (03) 209-249
  • 2 Parker SH, Jobe WE, Dennis MA. et al. US-guided automated large-core breast biopsy. Radiology 1993; 187 (02) 507-511
  • 3 Liberman L, Feng TL, Dershaw DD, Morris EA, Abramson AF. US-guided core breast biopsy: use and cost-effectiveness. Radiology 1998; 208 (03) 717-723
  • 4 Smith DN, Rosenfield Darling ML, Meyer JE. et al. The utility of ultrasonographically guided large-core needle biopsy: results from 500 consecutive breast biopsies. J Ultrasound Med 2001; 20 (01) 43-49
  • 5 Fishman JE, Milikowski C, Ramsinghani R, Velasquez MV, Aviram G. US-guided core-needle biopsy of the breast: how many specimens are necessary?. Radiology 2003; 226 (03) 779-782
  • 6 Fajardo LL, Pisano ED, Caudry DJ. et al; Radiologist Investigators of the Radiologic Diagnostic Oncology Group V. Stereotactic and sonographic large-core biopsy of nonpalpable breast lesions: results of the Radiologic Diagnostic Oncology Group V study. Acad Radiol 2004; 11 (03) 293-308
  • 7 Jackman RJ, Nowels KW, Rodriguez-Soto J, Marzoni Jr FA, Finkelstein SI, Shepard MJ. Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: false-negative and histologic underestimation rates after long-term follow-up. Radiology 1999; 210 (03) 799-805
  • 8 Darling ML, Smith DN, Lester SC. et al. Atypical ductal hyperplasia and ductal carcinoma in situ as revealed by large-core needle breast biopsy: results of surgical excision. AJR Am J Roentgenol 2000; 175 (05) 1341-1346
  • 9 Han BK, Choe YH, Ko YH, Nam SJ, Kim JH, Yang JH. Stereotactic core-needle biopsy of non-mass calcifications: outcome and accuracy at long-term follow-up. Korean J Radiol 2003; 4 (04) 217-223
  • 10 Burbank F, Parker SH, Fogarty TJ. Stereotactic breast biopsy: improved tissue harvesting with the Mammotome. Am Surg 1996; 62 (09) 738-744
  • 11 Berg WA, Krebs TL, Campassi C, Magder LS, Sun CC. Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model. Radiology 1997; 205 (01) 203-208
  • 12 Parker SH, Klaus AJ, McWey PJ. et al. Sonographically guided directional vacuum-assisted breast biopsy using a handheld device. AJR Am J Roentgenol 2001; 177 (02) 405-408
  • 13 Yu YH, Liang C, Yuan XZ. Diagnostic value of vacuum-assisted breast biopsy for breast carcinoma: a meta-analysis and systematic review. Breast Cancer Res Treat 2010; 120 (02) 469-479
  • 14 Penco S, Rizzo S, Bozzini AC. et al. Stereotactic vacuum-assisted breast biopsy is not a therapeutic procedure even when all mammographically found calcifications are removed: analysis of 4,086 procedures. AJR Am J Roentgenol 2010; 195 (05) 1255-1260
  • 15 Kettritz U, Rotter K, Schreer I. et al. Stereotactic vacuum-assisted breast biopsy in 2874 patients: a multicenter study. Cancer 2004; 100 (02) 245-251
  • 16 Tsai HY, Chao MF, Ou-Yang F. et al. Accuracy and outcomes of stereotactic vacuum-assisted breast biopsy for diagnosis and management of nonpalpable breast lesions. Kaohsiung J Med Sci 2019; 35 (10) 640-645
  • 17 Fu SM, Wang XM, Yin CY, Song H. Effectiveness of hemostasis with Foley catheter after vacuum-assisted breast biopsy. J Thorac Dis 2015; 7 (07) 1213-1220
  • 18 Reporting BI. Data System (BI-RADS). Reston (VA): American College of Radiology; 1998
  • 19 Khalilzadeh O, Baerlocher MO, Shyn PB. et al. Proposal of a new adverse event classification by the Society of Interventional Radiology Standards of Practice Committee. J Vasc Interv Radiol 2017; 28 (10) 1432-1437 .e3
  • 20 Sheth RA, Baerlocher MO, Connolly BL. et al. Society of Interventional Radiology quality improvement standards on percutaneous needle biopsy in adult and pediatric patients. Journal of vascular and interventional radiology. J Vasc Interv Radiol 2020; 31 (11) 1840-1848
  • 21 Cassano E, Urban LA, Pizzamiglio M. et al. Ultrasound-guided vacuum-assisted core breast biopsy: experience with 406 cases. Breast Cancer Res Treat 2007; 102 (01) 103-110
  • 22 Suh YJ, Kim MJ, Kim EK. et al. Comparison of the underestimation rate in cases with ductal carcinoma in situ at ultrasound-guided core biopsy: 14-gauge automated core-needle biopsy vs 8- or 11-gauge vacuum-assisted biopsy. Br J Radiol 2012; 85 (1016): e349-e356
  • 23 Schueller G, Schueller-Weidekamm C, Helbich TH. Accuracy of ultrasound-guided, large-core needle breast biopsy. Eur Radiol 2008; 18 (09) 1761-1773
  • 24 Ancona A, Caiffa L, Fazio V. Digital stereotactic breast microbiopsy with the mammotome: study of 122 cases [in Italian]. Radiol Med (Torino) 2001; 101 (05) 341-347
  • 25 Brem RF, Schoonjans JM, Sanow L, Gatewood OM. Reliability of histologic diagnosis of breast cancer with stereotactic vacuum-assisted biopsy. Am Surg 2001; 67 (04) 388-392
  • 26 Burak Jr WE, Owens KE, Tighe MB. et al. Vacuum-assisted stereotactic breast biopsy: histologic underestimation of malignant lesions. Arch Surg 2000; 135 (06) 700-703
  • 27 Lai JT, Burrowes P, MacGregor JH. Diagnostic accuracy of a stereotaxically guided vacuum-assisted large-core breast biopsy program in Canada. Can Assoc Radiol J 2001; 52 (04) 223-227
  • 28 Yelland A, Graham MD, Trott PA. et al. Diagnosing breast carcinoma in young women. BMJ 1991; 302 (6777): 618-620
  • 29 Bernik SF, Troob S, Ying BL. et al. Papillary lesions of the breast diagnosed by core needle biopsy: 71 cases with surgical follow-up. Am J Surg 2009; 197 (04) 473-478
  • 30 Burbank F. Mammographic findings after 14-gauge automated needle and 14-gauge directional, vacuum-assisted stereotactic breast biopsies. Radiology 1997; 204 (01) 153-156
  • 31 Tseng HS, Chen YL, Chen ST. et al. The management of papillary lesion of the breast by core needle biopsy. Eur J Surg Oncol 2009; 35 (01) 21-24
  • 32 Park HL, Hong J. Vacuum-assisted breast biopsy for breast cancer. Gland Surg 2014; 3 (02) 120-127
  • 33 Simon JR, Kalbhen CL, Cooper RA, Flisak ME. Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results. Radiology 2000; 215 (03) 694-697
  • 34 Johnson AT, Henry-Tillman RS, Smith LF. et al. Percutaneous excisional breast biopsy. Am J Surg 2002; 184 (06) 550-554 , discussion 554
  • 35 Bohan S, Ramli Hamid MT, Chan WY. et al. Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions. Sci Rep 2021; 11 (01) 129
  • 36 Seely JM, Hill F, Peddle S, Lau J. An evaluation of patient experience during percutaneous breast biopsy. Eur Radiol 2017; 27 (11) 4804-4811

Zoom Image
Fig. 1 A 46-year-old woman with a history of nipple discharge from right breast underwent mammography. (A) Craniocaudal (CC) view showed regional distribution of amorphous calcification with associated density. Targeted ultrasound revealed an ill-defined hypoechoic lesion with multiple echogenic foci representative of microcalcifications (not shown). (B) Ultrasound image showing microcalcification (arrow) within the needle trough. (C) CC view showing post-VABB changes and clip marker in situ. Histopathology revealed fibrocystic change, apocrine metaplasia, duct hyperplasia without atypia, and microcalcifications. Patient is on routine surveillance.
Zoom Image
Fig. 2 A 72-year-old woman, treated case of triple negative breast cancer 20 years ago, on routine follow-up. Mammography (MG) showed a faint new density in the inner aspect. A small 5-mm irregular hypoechoic lesion was seen on ultrasonography (US), and confirmed to represent the corresponding MG-detected lesion with a mammogram after placement of a (A) skin marker (triangle) and intralesional contrast instillation (B). US images showing (C) hypoechoic lesion (arrow) and the (D) needle along its inferior aspect (arrow head). Histopathology revealed invasive ductal carcinoma.
Zoom Image
Fig. 3 A 45-year-old woman with a family history of breast cancer underwent screening mammography. (A) Biopsy planning craniocaudal view of left breast showed pleomorphic calcification in segmental distribution. (B) Needle at target site. (C) Specimen radiograph confirming microcalcification in biopsy cores. Histopathology revealed ductal carcinoma in situ, which was further confirmed on subsequent surgery.
Zoom Image
Fig. 4 A 42-year-old woman with clinically palpable right breast lump. Ultrasonography revealed a well-defined oval hypoechoic mass (solid arrow). Vacuum-assisted breast biopsy (VABB) was performed with intent of excision. (A) VABB needle probe is seen along the inferior aspect of the mass (arrowheads). (B) Gradual decrease in lesion size (split-end arrow) with visible cutting edge (triangle). Histopathology confirmed cellular fibroadenoma. Patient is on follow-up.
Zoom Image
Fig. 5 Evolution of hematoma in relation to vacuum-assisted breast biopsy guiding modality (stereotactic guided vs. ultrasound guided).
Zoom Image
Fig. 6 Evolution of hematoma in relation to vacuum-assisted breast biopsy needle gauge (10G vs. 7G).