RSS-Feed abonnieren

DOI: 10.1055/s-0045-1809313
The Influence of Pressing Methods on the Change of Vertical Dimension of Occlusion in Full Dentures
Abstract
Objective
The objective of this study was to evaluate the alteration of the vertical dimension of occlusion (VDO) of full dentures when different pressing methods are used during the laboratory procedure.
Materials and Methods
Sixty specimens were divided into four groups (n = 15). In all cases, as an antagonist model, a standard assembly with cast alloy teeth was used, all the top pressed models were mounted in semiadjustable articulator through a metal reassembly plate. The vertical distance evaluation was performed by vertical measurement, using a digital caliper. The groups were divided as follows: group 1 (the muffle was not opened, and the space propitiator was not used), group 2 (the muffle was opened and the space propitiator was not used), group 3 (the muffle was not opened and the space propitiator was used), and group 4 (the muffle was opened and the space propitiator was used). In the four groups inclusions were carried out with zero expansion gypsum, 1000 kgf press, Vipi STG muffle and Vipi thermopolymerizable resin. The four groups were polymerized by the microwave power system with 800 watts of power.
Statistical Analysis
Statistical analysis was performed using one-way analysis of variance and Tukey's post hoc test (α = 0.05).
Results
Groups 3 and 4 presented the smallest change in the vertical occlusion dimension.
Discussion
Given the methodology applied in this study, the space propitiator was able to act significantly in reducing the change in VDO. There are many factors related to dimensional changes in the bases of full dentures. The dimensional changes and its relationship with the movements of artificial teeth have been observed. Some studies have shown that fixing or not fixing the artificial teeth before pressing does not prevent tooth displacement during subsequent polymerization and flasking stages.
Conclusion
The use of the space provider was effective in decreasing the vertical occlusion dimension, while the opening of the muffle for removal of the excess acrylic resin proved to be dispensable.
Introduction
Since the development in dentistry, in 1936, of the acrylic resin based on methyl methacrylate, it has been a challenge for dental surgeons to control the consequences of its alterations in the manufacture of the base of total prostheses.[1] [2] [3] The change in vertical dimension of occlusion (VDO) resulting from the polymerization of full dentures may affect the condylar and occlusal relationships of patients, tension in the facial muscles, and noise from the dentures during speech or even an aged facial appearance.[4] [5]
Goodacre et al reported that after the prosthesis is polymerized there are changes in the laboratory process with the incorporation of errors, which can change the VDO.[6] [7] [8] [9] Thus, it is necessary to have a rigorous control and knowledge of materials in this phase since the VDO should remain unchanged, from the stage of making the occlusion arches until the finalized prosthesis is placed in the patient's mouth.
Compagnoni et al evaluated the influence of the polymerization cycle on the VDO in total prostheses and concluded that regardless of the polymerization cycle used, there were changes in the VDO in total prostheses, with average increases prevailing in all of them.[10] [11] Goldstein et al developed research where he evaluated the alteration of the VDO in superior total prostheses and in acrylizations with microwave energy polymerization cycle and concluded that the acrylized superior total prostheses presented a smaller alteration in the VDO.[5]
Other changes may also occur[12] [13] due to linear contraction of acrylic resin, plaster expansion, incorrect inclusion, and induced tensions, all are factors that induce changes in the vertical dimension by spatial movement of teeth.[1] [10] [14] [15] [16] In order to control some of the dimensional changes that occur during the processing of total prostheses, it is interesting to use a technique that proposes an internal relief in the muffle in order to create a space for the acrylic resin to accommodate and be expelled, reducing the formation of internal stresses and allowing the two parts of the muffle to adapt correctly, minimizing the dimensional change of acrylic resin that causes an increase in the VDO.[17] [18] [19] This study evaluated methodologies of inclusion and polymerization, seeking the results that present less change in the VDO. The aim of this study was to evaluate the change in the VDO of full dentures when different pressing methods were used during the laboratory procedure, with the null hypothesis of not changing the DVO using the space provider.
Materials and Methods
The working models were obtained from a master maxillary model of special plaster type IV zero stone, from this master model a rubber mold was reproduced with industrial silicone and then from this rubber mold 60 models were reproduced with special plaster type IV zero stone ([Fig. 1A]), where 23 mL of distilled water were used for each 100 g of plaster spread in a vacuum spreader (Metal Vander) being 15 models for each group.


The lower mandibular model was obtained using a standard master model, where all teeth are of cast metal structure ([Fig. 1B]).
A double total prosthesis was assembled with the aid of the camper table on an ASA A7 Plus Bio Art, the upper model with Triunfo brand stock teeth, models 264, 34L, in color 62, antagonizing with a standard mandibular lower model, where all teeth were of cast metal structure, and the guide pin was kept at the zero demarcation, touching the center of the incisal table ([Fig. 1C–E]).
From this assembly, another copy was made with industrial silicone rubber for molds Siqmol 6008 (Siquiplas, São Paulo, Brazil), in order to have the reproduction and standardization of the model and maxillary assembly set. Next, the stock teeth were positioned in the “master mold” to obtain the 60 standardized assemblies ([Fig. 2A] and [B]).


Using the standard model mount, 60 replicas of the standard mount were reproduced, and all these mounts were mounted in ASA ([Fig. 3A–D]) at the same height as the incisal guide pin at zero and with the split-cast/magnet-plaster assembly.


After assembling the teeth, the inclusions were divided into four different groups. All 60 prostheses were included together with the plaster-magnet base, relieved with Labor Mass Condensation Silicone (Vipi Produtos Odontológicos Ltda, Pirassununga, São Paulo, Brazil) for laboratory use, and isolated with VIPI FILM Acrylic Resin Insulator (VIPI Produtos Odontológicos Ltda). All 60 inclusions in the muffle base were standardized in the same way, using a microwave muffle, Zero Arti (Dentona AG - Otto-Hahn-Str.27.44227, Dortmund, Germany) and zero-expansion stone plaster (Dentona AG - Otto-Hahn-Str.27.44227) spatulated in a Metal Vander vacuum spatulator (Metal Vander, Piracicaba, São Paulo, Brazil).
The models were divided into four groups with 15 models each, with two different inclusion methods in the counter-muffle, as shown in [Table 1].
-
- Group 1 (the muffle was not opened, and the space maintainer was not used)
In this first group no inclusion with space builder was performed. After crystallization and smoothing of the plaster at the base of the muffle, the common plaster at the base was isolated with pasty Vaseline and then a type IV Zero Stone plaster wall (Dentona AG - Otto-Hahn-Str.27.44227) was made, and then the rest of the counter-muffle was completed with the same plaster ([Fig. 4A–D]).
After crystallization of the plaster in the counter-muffle, the muffles were opened, washed with hot water, degreased with detergent, and insulated with acrylic resin insulators, and polymerized with Vipi Cril Plus (Vipi Produtos Odontológicos Ltda) thermopolymerizable acrylic resin.
The acrylic resin was pressed with the muffle at 1,000 kg/f in a hydraulic press (Vipi Produtos Odontológicos Ltda), the muffle was not opened, and the resin “rested” in the press for a period of 12 hours. Then, the muffle was hydrated for 10 minutes in water and polymerized by the microwave system technique.
An Eletroclux microwave oven (800–1,200 watts model) was used and polymerized at 30 w for 10 minutes, 0 power for 10 minutes, and 40 power for 10 minutes. The cooling was natural and the demoulding was done with the aid of a pneumatic demoulder, preserving the model with the magnet/plaster set, which will be returned to the articulator. This polymerization protocol was used in all four groups.
The prosthesis was reassembled on the ASA using the magnet/plaster/split-cast system ([Fig. 5A]). The measurement of the VDO variation, which occurred in all groups, was measured and standardized for the four groups as follows:
The distance from the guide pin clearance to the incisal table was filled using 0.1 mm thick polyester strips (Leaf Gauge) until they touched on both sides ([Fig. 5B]). The strips were removed and with a Mitutoyo Digital Pachymeter the VDO variation was measured ([Fig. 5C]).
-
- Group 2 (the muffle was opened, and the space builder was not used)
For group 2, no inclusion with space builder was performed. After crystallization and smoothing of the plaster at the base of the muffle, the common plaster at the base was isolated with pasty Vaseline, and then a Zero Stone (Dentona AG - Otto-Hahn-Str.27.44227) type IV plaster wall was made, and then the rest of the counter muffle was completed with the same plaster. Different from group 1, after carving and pressing at 1,000 kg/f, the muffle was opened after 3 hours of pressing ([Fig. 6]), where a large film of excess resin also formed, this film was removed, and the prosthesis was pressed for another 12 hours (rest time). The polymerization and laboratory reassembly occurred following the pattern adopted in group 1.
-
- Group 3 (the muffle was open, and the space improver was not used)
For group 3, the space builder was used, which according to the methodology described by Nogueira,[19] consists in applying a 2-mm thick layer of wax to the plaster on the base of the muffle, within 3 mm around the model ([Fig. 7A]). The counter-muffle is filled and after the removal of the wax, a space will remain to accommodate the excess acrylic resin without moving the edges of the muffle, reducing the formation of internal tensions to the mass caused by the different coefficients of thermal expansion of the plaster, resin, and muffle.
Then, the wall was made with zero expansion stone plaster type IV and the complement of the muffle with the same plaster equally in groups 1 and 2. Pressing of the muffle with the acrylic resin at 1,000 kg/f in a hydraulic press, the muffle was not opened and was left resting in the press for a period of 12 hours, and then the muffle was hydrated for 10 minutes in water and polymerized by the microwave system technique. The formation of an excess resin layer was noted ([Fig. 7B]). The measurements of the variations were also performed equally to groups 1 and 2.
-
- Group 4 (the muffle was opened, and the space builder was used)
For group 4, until the acrylic resin pressing stage, the same steps were followed as for group 3, with the use of the space builder and, similarly to group 2, opening the muffle after 3 hours of pressing to remove the excess resin that was formed in the space created by the space builder wax ([Fig. 8]). Again, the muffle was closed and left resting in the press for another 12-hour period, and then the muffle was hydrated for 10 minutes in water and polymerized by the microwave system technique. The results were also measured according to groups 1, 2, and 3.
Prior to the analyses, the data of change in VDO of the total prostheses were evaluated for normality by the Kolmogorov–Smirnov test. Then, they were submitted to one-way analysis of variance. The factor of the study was the pressing method used. Multiple comparisons were performed by Tukey's test. Statistical calculations were conducted adopting the significance level of 5% (α = 0.05), in the SigmaStat 3.5 program (Systat Software Inc., San Jose, California, United States).










Results
[Table 2] shows the mean values and standard deviation of the change in VDO of the full dentures.
Note: Averages followed by distinct letters indicate significant difference.
The two-way analysis of variance showed that there was a statistically significant interaction between the factors studied (p < 0.001).
According to Tukey's test, groups G1 and G2 showed the highest values of change in VDO, showing no statistically significant difference between them. Groups G3 and G4 showed the lowest values of change in VDO and showed no statistically significant difference between them.
Discussion
Considering the increase in VDO caused by the dimensional changes of acrylic resins, it is important to evaluate these alterations in complete dentures. After the polymerization of the acrylic resin is complete—but before the prosthesis is removed from the model - it should be repositioned in its original location on the articulator. This allows for the occlusion to be rechecked and, if necessary, corrected through adjustments.[20] [21]
Polymethylmethacrylate is the most common resin used in the manufacture of total prostheses, and since its appearance there has been a continuous search to improve its physical and mechanical properties.[15] [22] The technical evolution achieved was not enough to totally dominate its alterations, and several techniques have been modified and introduced in order to minimize such alterations.[13]
According to several authors, numerous researches have been performed with the purpose of controlling the dimensional changes in relation to the increase in the VDO.[2] [13] [20] [23] Given the methodology applied in this study, the space propitiator was able to act significantly in reducing the change in VDO.
There are many factors related to dimensional changes in the bases of full dentures. Numerous authors observed the dimensional changes and its relationship with the movements of artificial teeth.[1] [10] [15] [16] [22] Some studies have shown even with the fixation or not of the artificial teeth, before pressing, it does not prevent tooth movement during the following stages of polymerization and noninclusion.[10] [15] [16]
According to Consani et al, the insertion phase of the acrylic resin is one of the relevant factors in the dimensional change of the prosthesis base and consequently increase in the VDO, concluding that the plastic phase was the one that provided less misfit[13] [20]; however, Turano et al[24] and Gomez et al[25] do not agree with this result, stating that the plastic phase makes an excessive pressure in the pressing, modifying the position of the teeth.
Differently from the results found in this research, the acrylic resin was not pressed in the plastic phase, agreeing with Turano et al[24] and Gomez et al.[25] The opening of the muffle when done, for once, without the propitiator as shown in group 2, had a small decrease in the VDO compared to group 1. When the muffle opening was associated with the space opener as shown in group 4, there was a decrease compared to group 3. Even if statistically the difference between group 4 and group 3 is not significant, opening the muffle is necessary because it helps to reduce internal stresses in the acrylic mass, as reported by several authors.[14] [25] [26]
In this research, the muffle was opened only once, but it would have been possible to open it more times for the removal of excesses, which would facilitate a better adaptation of the muffle and counter-muffle. However, this did not occurred, due to the risk of fatigue of the materials involved due to the multiple pressings. Therefore, these results agree with variables of VDO found by Mahler (1951)[28], which was on average 0.6 mm, as well as Woelfel et al[27], which alternated from 0.00 to 1.49 mm, Dukes et al (1983)[29] who found variables of 1.57 mm on average, of which 0.55 mm was base and 1.02 mm on account of dental change, in addition to Savabi et al, who found changes ranging from 0.03 to 1.02 mm.[28]
Conclusion
According to the methodology applied and the results obtained, it can be concluded that the space propitiator technique is effective and contributed significantly in reducing the change in the VDO of full dentures. Furthermore, opening the muffle once to remove excess acrylic resin before polymerization was not effective in controlling changes in the VDO of full dentures.
Conflict of Interest
Kusai Baroudi reports all support for the present manuscript from “Ajman University”.
Acknowledgement
The authors thank Ajman University for its support.
Data Availability Statement
Data is available under request.
-
References
- 1 Barbosa DB, Compagnoni MA, Leles CR. Changes in occlusal vertical dimension in microwave processing of complete dentures. Braz Dent J 2002; 13 (03) 197-200
- 2 Lima APB, Vitti RP, Amaral M, Neves ACC, da Silva Concilio LR. Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis. J Adv Prosthodont 2018; 10 (02) 122-127
- 3 Mengatto CM, Gameiro GH, Brondani M, Owen CP, MacEntee MI. A randomized controlled trial of mastication with complete dentures made by a conventional or an abbreviated technique. Int J Prosthodont 2017; 30 (05) 439-444
- 4 Rugh JD, Drago CJ. Vertical dimension: a study of clinical rest position and jaw muscle activity. J Prosthet Dent 1981; 45 (06) 670-675
- 5 Goldstein G, Goodacre C, MacGregor K. Occlusal vertical dimension: best evidence consensus statement. J Prosthodont 2021; 30 (S1): 12-19
- 6 Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J Prosthet Dent 2016; 116 (02) 249-256
- 7 Strohaver RA. Comparison of changes in vertical dimension between compression and injection molded complete dentures. J Prosthet Dent 1989; 62 (06) 716-718
- 8 Meloni SM, Jovanovic SA, Urban I, Canullo L, Pisano M, Tallarico M. Horizontal ridge augmentation using GBR with a native collagen membrane and 1:1 ratio of particulated xenograft and autologous bone: a 1-year prospective clinical study. Clin Implant Dent Relat Res 2017; 19 (01) 38-45
- 9 Rehmann P, Künkel AK, Weber D, Lotzmann U, Wöstmann B. Using a modified neutral zone technique to improve the stability of mandibular complete dentures: a prospective clinical study. Int J Prosthodont 2016; 29 (06) 570-572
- 10 Compagnoni MA, Barbosa DB, Leles CR, Júnior CAB. Influência da remontagem na alteração da dimensão vertical de oclusão em próteses totais. Braz Dent Sci 2010;4(2)
- 11 Salloum AM. Influence of high expansion dental stone used as investing medium on the changes in occlusal vertical dimension of complete dentures. Saudi Dent J 2013; 25 (04) 135-140
- 12 Dos Santos MBF, Consani RLX, Mesquita MF. Influence of different metal flask systems on tooth displacement in complete upper dentures. Gerodontology 2012; 29 (01) 30-35
- 13 Consani RLX, Paula AB, Fugolin APP, Pfeifer CS. Strategies for potential toughening of acrylic denture bases polymerized with microwave energy. Braz Dent J 2020; 31 (05) 523-531
- 14 Grunewald AH, Paffenbarger GC, Dickson G. The effect of molding processes on some properties of denture resins. J Am Dent Assoc 1952; 44 (03) 269-284
- 15 Pero AC, Marra J, Polatto CA, Barbosa DB, Compagnoni MA. Resistência de união entre dentes artificiais e resinas acrílicas para base protética. Polímeros 2007; 17 (03) 194-200
- 16 Babu S, Manjunath S, Vajawat M. Effect of palatal form on movement of teeth during processing of complete denture prosthesis: an in-vitro study. Contemp Clin Dent 2016; 7 (01) 36-40
- 17 Nogueira SS, Ogle RE, Davis EL. Comparison of accuracy between compression- and injection-molded complete dentures. J Prosthet Dent 1999; 82 (03) 291-300
- 18 Georgetti BA, Georgetti MP, de Oliveira AC. Prótese Total: uma criação mecânica, biológica e estética. In: Morais Jde. ed. Atualização em prótese dentária: procedimentos clínico e laboratorial. Curitiba: Maio; 2003: 47-67
- 19 Consani RLX, Domitti SS, Rizzatti-Barbosa CM, Consani S. Effect of packing pressure and post-pressing time on the dimensional stability of complete denture bases. J Prosthet Dent 2002; 88 (04) 369-373
- 20 Consani RLX, de Paula AB, Fugolin APP, Pfeifer CS. Effect of the combination of a crosslinking agent and a thiourethane additive on the properties of acrylic denture bases processed with microwave energy. J Mech Behav Biomed Mater 2019; 98: 90-95
- 21 Salloum AM. Effect of three investing materials on tooth movement during flasking procedure for complete denture construction. Saudi Dent J 2016; 28 (01) 56-61
- 22 Einarsdottir ER, Geminiani A, Chochlidakis K, Feng C, Tsigarida A, Ercoli C. Dimensional stability of double-processed complete denture bases fabricated with compression molding, injection molding, and CAD-CAM subtraction milling. J Prosthet Dent 2020; 124 (01) 116-121
- 23 Rizzatti-Barbosa CM, Machado C, Joia FA, dos Santos Sousa RL. A method to reduce tooth movement of complete dentures during microwave irradiation processing. J Prosthet Dent 2005; 94 (03) 301-302
- 24 Turano LM, Ferreira FF, Marcello V-BT, Turano MVB, Turano GVB. Is it true that one can change the vertical distance to the complete denture during the polymerization process [in Portuguese]?. PCL Rev Bras Protese Clin Lab 2003; 5 (24) 152-157
- 25 Gomez T, Mori M, Corrêa Gde A. Alternativas técnicas para o controle das alterações dimensionais das resinas acrílicas em prótese total. Rev Odontol Univ Sao Paulo 1998; 12 (02) 181-187
- 26 Pellizzer AJ, Bombonatti PE, Gennari FilhoH. Influence of flask lining with foam-rubber in the changing of the vertical dimension in complete dentures [in Portuguese]. Rev Odontol UNESP 1981; 10 (1/2): 45-48
- 27 Woelfel JB, Paffenbarger GC, Sweeney WT. Dimensional changes occurring in dentures during processing. J Am Dent Assoc 1960; 61 (04) 413-430
- 28 Mahler DB. Inarticulation of complete dentures processed by the compression molding technique. J Prosthet Dent 1951; 1 (05) 551-559
- 29 Dukes BS, Fields HJr, Olson JW. A laboratory study of changes in vertical dimension using acrylic resin and porcelain teeth. J Am Dent Assoc 1983; 106 (06) 842-843
- 30 Savabi G, Savabi O, Dastgheib B, Nejatidanesh F. Effect of the processing cycle on dimensional changes of heat-polymerized denture base resins. Dent Res J (Isfahan) 2015; 12 (04) 301-306
Address for correspondence
Publikationsverlauf
Artikel online veröffentlicht:
30. Mai 2025
© 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)
Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
-
References
- 1 Barbosa DB, Compagnoni MA, Leles CR. Changes in occlusal vertical dimension in microwave processing of complete dentures. Braz Dent J 2002; 13 (03) 197-200
- 2 Lima APB, Vitti RP, Amaral M, Neves ACC, da Silva Concilio LR. Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis. J Adv Prosthodont 2018; 10 (02) 122-127
- 3 Mengatto CM, Gameiro GH, Brondani M, Owen CP, MacEntee MI. A randomized controlled trial of mastication with complete dentures made by a conventional or an abbreviated technique. Int J Prosthodont 2017; 30 (05) 439-444
- 4 Rugh JD, Drago CJ. Vertical dimension: a study of clinical rest position and jaw muscle activity. J Prosthet Dent 1981; 45 (06) 670-675
- 5 Goldstein G, Goodacre C, MacGregor K. Occlusal vertical dimension: best evidence consensus statement. J Prosthodont 2021; 30 (S1): 12-19
- 6 Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J Prosthet Dent 2016; 116 (02) 249-256
- 7 Strohaver RA. Comparison of changes in vertical dimension between compression and injection molded complete dentures. J Prosthet Dent 1989; 62 (06) 716-718
- 8 Meloni SM, Jovanovic SA, Urban I, Canullo L, Pisano M, Tallarico M. Horizontal ridge augmentation using GBR with a native collagen membrane and 1:1 ratio of particulated xenograft and autologous bone: a 1-year prospective clinical study. Clin Implant Dent Relat Res 2017; 19 (01) 38-45
- 9 Rehmann P, Künkel AK, Weber D, Lotzmann U, Wöstmann B. Using a modified neutral zone technique to improve the stability of mandibular complete dentures: a prospective clinical study. Int J Prosthodont 2016; 29 (06) 570-572
- 10 Compagnoni MA, Barbosa DB, Leles CR, Júnior CAB. Influência da remontagem na alteração da dimensão vertical de oclusão em próteses totais. Braz Dent Sci 2010;4(2)
- 11 Salloum AM. Influence of high expansion dental stone used as investing medium on the changes in occlusal vertical dimension of complete dentures. Saudi Dent J 2013; 25 (04) 135-140
- 12 Dos Santos MBF, Consani RLX, Mesquita MF. Influence of different metal flask systems on tooth displacement in complete upper dentures. Gerodontology 2012; 29 (01) 30-35
- 13 Consani RLX, Paula AB, Fugolin APP, Pfeifer CS. Strategies for potential toughening of acrylic denture bases polymerized with microwave energy. Braz Dent J 2020; 31 (05) 523-531
- 14 Grunewald AH, Paffenbarger GC, Dickson G. The effect of molding processes on some properties of denture resins. J Am Dent Assoc 1952; 44 (03) 269-284
- 15 Pero AC, Marra J, Polatto CA, Barbosa DB, Compagnoni MA. Resistência de união entre dentes artificiais e resinas acrílicas para base protética. Polímeros 2007; 17 (03) 194-200
- 16 Babu S, Manjunath S, Vajawat M. Effect of palatal form on movement of teeth during processing of complete denture prosthesis: an in-vitro study. Contemp Clin Dent 2016; 7 (01) 36-40
- 17 Nogueira SS, Ogle RE, Davis EL. Comparison of accuracy between compression- and injection-molded complete dentures. J Prosthet Dent 1999; 82 (03) 291-300
- 18 Georgetti BA, Georgetti MP, de Oliveira AC. Prótese Total: uma criação mecânica, biológica e estética. In: Morais Jde. ed. Atualização em prótese dentária: procedimentos clínico e laboratorial. Curitiba: Maio; 2003: 47-67
- 19 Consani RLX, Domitti SS, Rizzatti-Barbosa CM, Consani S. Effect of packing pressure and post-pressing time on the dimensional stability of complete denture bases. J Prosthet Dent 2002; 88 (04) 369-373
- 20 Consani RLX, de Paula AB, Fugolin APP, Pfeifer CS. Effect of the combination of a crosslinking agent and a thiourethane additive on the properties of acrylic denture bases processed with microwave energy. J Mech Behav Biomed Mater 2019; 98: 90-95
- 21 Salloum AM. Effect of three investing materials on tooth movement during flasking procedure for complete denture construction. Saudi Dent J 2016; 28 (01) 56-61
- 22 Einarsdottir ER, Geminiani A, Chochlidakis K, Feng C, Tsigarida A, Ercoli C. Dimensional stability of double-processed complete denture bases fabricated with compression molding, injection molding, and CAD-CAM subtraction milling. J Prosthet Dent 2020; 124 (01) 116-121
- 23 Rizzatti-Barbosa CM, Machado C, Joia FA, dos Santos Sousa RL. A method to reduce tooth movement of complete dentures during microwave irradiation processing. J Prosthet Dent 2005; 94 (03) 301-302
- 24 Turano LM, Ferreira FF, Marcello V-BT, Turano MVB, Turano GVB. Is it true that one can change the vertical distance to the complete denture during the polymerization process [in Portuguese]?. PCL Rev Bras Protese Clin Lab 2003; 5 (24) 152-157
- 25 Gomez T, Mori M, Corrêa Gde A. Alternativas técnicas para o controle das alterações dimensionais das resinas acrílicas em prótese total. Rev Odontol Univ Sao Paulo 1998; 12 (02) 181-187
- 26 Pellizzer AJ, Bombonatti PE, Gennari FilhoH. Influence of flask lining with foam-rubber in the changing of the vertical dimension in complete dentures [in Portuguese]. Rev Odontol UNESP 1981; 10 (1/2): 45-48
- 27 Woelfel JB, Paffenbarger GC, Sweeney WT. Dimensional changes occurring in dentures during processing. J Am Dent Assoc 1960; 61 (04) 413-430
- 28 Mahler DB. Inarticulation of complete dentures processed by the compression molding technique. J Prosthet Dent 1951; 1 (05) 551-559
- 29 Dukes BS, Fields HJr, Olson JW. A laboratory study of changes in vertical dimension using acrylic resin and porcelain teeth. J Am Dent Assoc 1983; 106 (06) 842-843
- 30 Savabi G, Savabi O, Dastgheib B, Nejatidanesh F. Effect of the processing cycle on dimensional changes of heat-polymerized denture base resins. Dent Res J (Isfahan) 2015; 12 (04) 301-306















