RSS-Feed abonnieren

DOI: 10.1055/s-0045-1810442
Influence of Occlusal Cusp Inclination and Restoration Thickness on the Biomechanical Performance of Lithium Disilicate Molar Endocrowns: A 3D Finite Element Analysis
Abstract
Objectives
This study used finite element analysis to investigate the effect of occlusal cusp inclination and restoration thickness of endocrowns on the stress distribution and biomechanical performance.
Materials and Methods
A total of six models of a mandibular first molar representing two different heights of remaining tooth structure above the cemento-enamel junction (1.5 and 3 mm), each with three different buccal cusps inclination angles (original, 10 degrees, and 20 degrees increase in cusp inclination angles) were generated. Models were designated as: 1.5/original, 1.5/10 degrees, 1.5/20 degrees, 3/original, 3/10 degrees, and 3/20 degrees. All models were subjected to an oblique load of 400 N. The maximum principal stress (MPS), maximum shear stress (MSS) at the cement interface, and factor of safety (FoS) were calculated.
Results
Increasing the cuspal inclination by 10 degrees in models with a 1.5-mm remaining tooth structure, resulted in a 20% reduction of the MPS in the dentine (27.2 MPa), in comparison with original cuspal inclines (33.9 MPa). However, increasing the cusp inclination in model 1.5/20 degrees resulted in a comparable dentinal stress reduction (17%, 28 MPa) accompanied with an increase in the MSS at the cement interfaces (26.8 MPa), in comparison with 1.5/original (18 MPa). On the other hand, increasing the cusp inclination angle in models 3/10 degrees and 3/20 degrees led to a reduction in MPS within the dentine by 1 and 2%, respectively, while causing an increase in the MSS at the cement interfaces (16.4 and 16.0 MPa, respectively), in comparison with 3/original (11 MPa). Models 1.5/original and 3/original reported the minimum FoS values (3.10 and 3.38, respectively), while model 1.5/10 degrees reported the highest FoS value (3.86).
Conclusion
Within the limitations of the current study, cusp inclination adjustments up to 10 degrees may enhance stress distribution in endocrown-restored molars with limited coronal structure.
Keywords
endocrowns - finite element analysis - lithium disilicate - occlusal design - root canal treated teeth - stress distributionIntroduction
The restoration of endodontically treated teeth (ETT) with extensive loss of structure continues to be a challenging procedure in restorative dentistry as they are more prone to fractures than vital teeth.[1] [2] First introduced in the late 1990s, endocrowns have recently gained renewed attention as an alternative and more conservative option to restore ETT.[3] [4]
The endocrown restoration combines multiple design features to enhance biomechanical performance and retention. An occlusal onlay-like preparation is performed to achieve cuspal coverage and protection, helping to reduce the risk of fracture by redistributing occlusal forces away from the weakened tooth structure.[4] The intraradicular extension of the endocrown material into the endodontic access cavity increases the surface area available for bonding, thereby enhancing the overall retention of the restoration.[5] Moreover, preserving enamel at the cavosurface margin provides a reliable substrate for adhesive bonding.[6]
Several studies investigated the ideal restorative material to fabricate endocrowns, reporting the use of monolithic computer-aided design and different computer-aided manufacturing materials.[5] [7] [8] Among these materials, lithium disilicate glass ceramics (LDGC) has been recommended, mainly as they possess high esthetic and high adhesion values.[9] [10]
The long-term clinical performance of indirect restorations depends, among other factors, on the physicomechanical properties of the prosthetic materials, as well as the preparation design parameters and anatomical features of the restoration.[11] [12] Clinical design parameters such as margin geometry, preparation height, thickness, and cusp inclination significantly affect the restoration's performance and fracture behavior.[12] Steep cusp inclines have been of concern as one of the predisposing factors for the incidence of tooth fracture in posterior dentition.[13] Although the restoration design could be influenced by the clinical requirements, several adjustments of the cusp inclination and anatomic features strongly depends on the skills and preferences of the dental clinician or technician.[14]
During clinical function, the restoration design and volume can also affect the ability of the restorative material to dissipate masticatory loads and the material's mechanical response during stress concentration.[15] [16] Due to the larger material thickness in endocrown designs compared to conventional crowns, the stiffness of the whole restoration increases and the tension is reduced at the restoration–cement interfaces. In such cases, crack formation normally starts from the occlusal loading surface and the stress will be affected by the occlusal complexity of the restorations.[7] Although previous studies investigated the effect of different preparation designs of endocrown-restored teeth on fracture resistance,[2] investigations of the complex occlusal geometry design on the stress distribution and failure probability of all-ceramic LDGC endocrowns have not been reported.
Simulation studies, such as finite element analysis (FEA), are still valuable in endodontic research. They provide useful insights in cases where conducting randomized clinical trials is not feasible.[17] FEA-based studies are well accepted when investigating various biomechanical properties that can be difficult to assess under in vitro or in vivo conditions.[18] [19] Therefore, the aim of this FEA study was to investigate the influence of the endocrown restoration thickness and cusp inclination angle, and a combination of these effects on the biomechanical behavior of LDGC molar endocrowns. The null hypothesis was that the restoration thickness and cusp inclination angle would not significantly affect the stress concentration of the LDGC endocrowns on molars.
Material and Methods
Sample Selection and FEA Model Generation
An intact mature human mandibular first molar was scanned with a resolution of 27 μm, using an Inveon Multimodality single photon emission computed tomography (CT) scanner (Siemens Preclinical Solutions, Knoxville, Tennessee, United States).
The scanned tooth had a typical occlusal anatomy with five distinct cusps of sufficient cusp inclination ([Fig. 1A]) as well as typical radicular anatomy with two mature roots enclosing three root canals.[20] Materialize interactive medical image control system (MIMICS version 21; Materialise, Leuven, Belgium) was used to reconstruct the Digital Imaging and Communications in Medicine images obtained. The software was used to identify enamel and dentine, form the masks, and grow threshold regions automatically. Regions were visually confirmed to avoid discrepancies before the three-dimensional (3D) model was produced. The periodontal ligaments and the surrounding bone investment were finally assembled with the tooth using SolidWorks (Dassault Systemes, Paris, France). Geomagic Design (3D Systems, Rock Hill, South Carolina, United States) was used to confirm the absence of exceptionally sharp edges or contact lines.


Tooth Preparation and Endocrown Design
Two models were replicated from the original sound tooth model. The crown of the first model was sectioned at 1.5 mm above the cemento-enamel junction (CEJ), while the crown of the second model was sectioned at 3 mm above the CEJ ([Fig. 1A] and [B]). The access cavity walls were prepared with 8 degrees wall inclination angle,[21] and the root canals were symmetrically enlarged around their long axes to simulate radicular shaping before being filled with simulated gutta-percha. The utilized endocrown design included a butt joint occlusal preparation at the level of tooth sectioning and a central retention core extending from the level of the butt joint to the base of the access cavity. The occlusal portion of the endocrown corresponded to the original occlusal anatomy of the tooth before sectioning ([Fig. 1B] and [C]). The cement interface between the prepared tooth and endocrown was simulated with a thin layer of average thickness of 80 μm ([Fig. 1C]).[8]
Cusp Inclination Angle
For both designed models (sectioned at 1.5 and 3 mm above the CEJ), three cusp inclination angles for the buccal cusps (mesiobuccal, distobuccal, and distal cusp) were designed: original cuspal inclinations, 10 degrees increase in cusp inclination angle, and 20 degrees increase in cusp inclination angle ([Fig. 1D]). A total of six geometrical models were generated and designated as: 1.5/original, 1.5/10 degrees, 1.5/20 degrees, 3/original, 3/10 degrees, and 3/20 degrees. Endocrown elements were coupled to the material properties of LDGC while the cement layer elements were coupled to the material properties of resin cement (Variolink II, Ivoclar Vivadent, Schaan, Liechtenstein) ([Fig. 1A]–[C]).
Meshing and Set Material Properties
The geometrical models described above were imported to the FEA software, ANSYS 19.3 software (ANSYS, Canonsburg, Pennsylvania, United States) for simulation. Parabolic tetrahedral solid elements were used in the meshing design of all experimental models. The meshes were generated through a convergence test of 10% strain energy and displacement variation. The mesh was checked for element quality and refined in the areas of interest ([Fig. 1E]). The mesh convergence test with total nodes and elements in each test model was as follows:
-
Test 1: 484523 and 347219 nodes and elements, respectively.
-
Test 2: 598862 and 427118 nodes and elements, respectively.
-
Test 3: 720209 and 541828 nodes and elements, respectively.
The final number of total elements and nodes in the experimental models varied between 541828 to 582435 elements and 720209 to 789504 nodes.
The simulated materials used in this study were considered linear, elastic, homogenous, and isotropic. Ideal adherence was assumed between structures. The applied material properties were based on previous FEA studies as listed in [Table 1].[18] [22] [23]
Load and External Conditions
To simulate clinical masticatory conditions, all models were subjected to an oblique load of 400 N applied with an angle of 45 degrees to the longitudinal tooth axis ([Fig. 1E]).[24] [25] The loading was applied at three defined points, specifically on the mid-lingual facing inclines of the mesiobuccal, distobuccal, and distal cusps, as illustrated in [Fig. 1E]. Movement restriction at the distal, mesial, and bottom surfaces of the bone were applied.
Model Validation and Verification
The 3D mathematical model was directly validated against the natural tooth using the method detailed by a previous study.[26] Briefly, high-fusion wax (Galileo; Talladium Inc, Valencia, California, United States) was used to simulate the periodontal ligament, while a 3D-printed plastic block was employed to replicate the surrounding bone.[26] Next, the assembly was loaded three times by a universal testing machine and the displacement was registered. The results were compared to the FEA simulation predictions and a 5% maximum margin of error was deemed sufficient to validate the model.
The mesh design, solver settings, and boundary conditions were evaluated against established protocols in dental biomechanics literature. The finite element mesh was modeled based on validated approaches that approximate the complex geometries of the dental tissues and surrounding bone. Mesh convergence was performed as prescribed above. Material properties were derived from the most recent peer-reviewed studies, and the boundary conditions were reviewed to reflect realistic constraints such as those imposed by neighboring teeth. Verification procedures ensured consistency and the internal validity of the model.
Data Analysis
The maximum principal stress (MPS) was analyzed in the following areas of interest; the remaining dentine and enamel tooth structure, endocrowns, and resin cement. Stress distributions in different structures were presented to visualize the overall mechanical behavior. The maximum shear stress (MSS) values at the interfaces of the resin cement layer were analyzed.[27] The factor of safety (FoS) theory was used to assess the safety of the models based on the Mohr–Coulomb failure criterion at the endocrown and remaining dentine tooth structure (higher FoS values indicate greater safety and stability under load). The dentine ultimate tensile strength (UTS) and ultimate compressive strength (UCS) are 105 and 298 MPa, respectively.[18] The Mohr–Coulomb stress ratio (ςMC) and FoS were calculated as the following:




where ςmax is the maximum tensile principal stress, and ςmin is the minimum compressive principal stress.
Results
The MPS, MSS, and the FoS values are listed in [Table 2]. A visual representation is provided in [Fig. 2] showing MPS values and distribution patterns computed for the six FEA models.


Models with 1.5 mm Remaining Tooth Structure Above the CEJ
In this group, model 1.5/original resulted in the highest MPS at the remaining dentine (34 MPa) and enamel (82 MPa), followed by 1.5/20 degrees with MPS values of 28 MPa at the remaining dentine and 75 MPa at enamel. Finally, model 1.5/10 degrees registered MPS values of 27 MPa at the remaining dentine and 72 MPa at enamel.
Within the endocrown material, the MPS values were highest for model 1.5/20 degrees (300 MPa), followed by model 1.5/10 degrees (250 MPa), and least with model 1.5/original (199 MPa).
At the cement interface, MSS was similar in models 1.5/original and 1.5/10 degrees (18 MPa), while a higher value was reported in model 1.5/20 degrees (26 MPa).
Models with 3 mm Remaining Tooth Structure Above the CEJ
In this group, MPS values at the remaining dentine were similar across all three models (∼31 MPa). Enamel MPS values ranged from 90 to 93 MPa.
However, the endocrown material exhibited greater variation: model 3/10 degrees showed the highest MPS (316 MPa), followed by 3/20 degrees (239 MPa), and 3/original (199 MPa).
At the cement interface, MSS was similar in models 3/10 degrees and 3/20 degrees (16 MPa), while a lower value was reported in model 3/original (11 MPa).
Regarding the FoS values across all the six tested models, the minimum value was reported in model 1.5/original (3.10). For the remaining models, FoS ranged from 3.38 to 3.86, with model 1.5m/10 degrees reporting the highest FoS value (3.86).
Stress Distribution Patterns
There were no differences in MPS distribution patterns among the three models in each group (1.5 and 3 mm above the CEJ). However, a comparison of dentine stress patterns between the two groups reveals some differences. In the 3-mm models, areas of elevated stress (red zones) were primarily located at the cervical region ([Fig. 2]). In contrast, the 1.5-mm models demonstrated a wider extension of high stress areas (red zones), among the cervical area and the mid-root region ([Fig. 2]). Nonetheless, all models consistently exhibited the highest stress concentration at the cervical region.
Discussion
FEA-based studies are valuable in assessing the biomechanical performance of complex clinical scenarios and are extensively used in endodontics.[18] [19] [22] The clinical performance and failure of a given material or dental procedure are significantly influenced by the knowledge of stress concentration and distribution patterns.[28] Therefore, this study utilized a FEA design to investigate the influence of the complex occlusal geometry, namely, endocrown thickness, cusp inclination angle, and a combination of these effects on the biomechanical behavior of all-ceramic molar endocrowns.
Overall, it was noted that increasing the cusp inclination by 10 degrees in endocrown models with a 1.5-mm tooth structure above the CEJ (model 1.5/10 degrees), resulted in a 20% stress reduction of the MPS in the remaining dentine. However, when the cusp inclination was increased by 20 degrees (model 1.5/20 degrees), the resultant comparable dentinal stress reduction (17%) is accompanied by an increase in the MSS at the cement interfaces. On the other hand, increasing the cusp inclination angle in the endocrown models with a 3-mm height above the CEJ (models 3/10 degrees and 3/20 degrees) by 10 and 20 degrees resulted in minimal MPS reduction in the remaining dentine of 1 and 2%, respectively, while causing an increase in the MSS at the cement interfaces. Hence, the null hypothesis was rejected. Occlusal geometry impacted the magnitude of stress generated upon loading. Also, the height of the remaining tooth structure, which dictates the vertical dimension of the restoration, affects how these variables manifest in the biomechanical behavior of the assembly.
Due to the complex anatomy of molars, the complex interaction with surrounding supporting tissues and the wide range of bite forces (10–1000 N) among patients, evaluating stresses within teeth under masticatory loading is extremely challenging.[29] To establish an average posterior bite force value, we applied a force of 400 N, ensuring that the applied force is within a realistic and accepted range of posterior teeth.[30] The oblique direction of force application was chosen to combine the multidirectional nature of occlusal forces, where contact rarely occurs in a purely vertical direction.[31] [32] Oblique loading replicate the worst-case clinical scenario, where unfavorable loading vectors may increase the risk of debonding or fracture and introduces shear and tensile stress components, which are more critical for evaluating failure risks. By doing so, the model's biomechanical response is tested under more demanding conditions, thereby enhancing the predictive value and safety margin of the restoration design being evaluated.[33] [34]
Stress distribution patterns within dentine do not seem to vary with the variation of the cuspal inclination when models with the same height of remaining tooth structure (1.5 or 3 mm) are compared. This can probably be explained by the fact that each triplet shared one restorative constant: the cement's volume, distribution, and layer thickness. Many studies have shown that interfaces hinder smooth force transition,[21] [35] so it seems plausible that given the limited thickness of the cement between its two wide interfaces, occlusal forces passing through the endocrown thickness and the cement layer would reach dentine in a similar distribution despite differences in the magnitude among models. However, it should be noted that a uniform 80 μm cement layer was used in the present study for standardization, though this does not reflect clinical variability.[36] Micro-CT analysis has demonstrated that cement thickness is often greater in pulpal and cervical areas, which may affect stress distribution and crack initiation.[5] Although such modeling simplifications are common in FEA studies, future research should explore the impact of nonuniform cement layers on endocrown performance.
Although stress distribution patterns appeared similar across the 1.5 and 3 mm models, the consistent concentration of peak stresses in the cervical region suggests a higher risk of structural failure in this area, reinforcing the need for effective cervical support in clinical restorations.[7] On the other hand, the stress distribution patterns on the external surface of the root are different when dentinal stress is compared between any two models of the same cuspal inclination but different heights of the remaining tooth structure (1.5 vs. 3 mm). When this observation is put along the close range of dentine MPS values, it supports the finding reported by previous studies that dentine has the capacity to disperse stresses over a larger surface area, which brings down its magnitude.[26]
Our findings also showed that the FoS seems to increase with increasing the cuspal inclination for models with the same vertical height of the shoulder. This can be attributed to the difference in force alignment as increasing the vertical cusp inclination angle brings the occlusal surface closer to a more favorable position to accommodate the load. The increase in FoS values was reported in the model with less remaining dental structure (i.e., larger restoration). In general, a FoS value greater than 1 suggests the model is safe, while a value less than 1 indicates failure. However, a FoS of 2 or more is commonly considered desirable in dental restorative applications to account for fatigue, stress concentrations, and patient variability.[37] [38] Values above 3, as observed in the current study, suggest a substantial margin of safety, indicating a robust design capable of withstanding variable clinical loading conditions.
On the other hand, the 20-degree increase risked earlier debonding as the shear stresses within the cement layer increased to beyond or at least within the ranges of the maximum reported shear stresses a resin cement can take.[6] Debonding of the cement in this scenario would not be regarded as a catastrophic failure, as the little remaining tooth structure is uncompromised and allows for another restoration. Further investigations are needed to determine whether or not increasing the cuspal inclination (within the range permitted by the patient's occlusion) can be considered a safeguard with clinical scenarios requiring extensive restorations and in premolars where the small occlusal table, the wedging nature of the occlusion, and the larger length-to-width ratio compared to molars increase the risk on unrestorable failures.[7] Well-planned clinical studies are needed to confirm or refute the findings of this study.
The study limitations are mostly dictated by shortcomings of current FEA capabilities. FEA simulations assume the ideal execution of the design and restoration production, which eliminates the effect of human error, variations in cement film thickness, and the impact of thermocycling.[39] While applying standardized static loading enhances model comparability and isolates cusp inclination and remaining tooth structure effects, it does not accurately replicate the variability of clinical occlusal contacts. Therefore, future work should incorporate multiple contact sites or patient-specific occlusal contact mapping and dynamic loading cycles to better simulate clinical mastication.[40] Moreover, static loading underestimates true functional stresses and fails to capture cyclic fatigue damage, which has been shown to cause longitudinal dentinal cracks under repeated loading. It also omits the weakening impact of cyclic stress on adhesive interfaces.[7] [41]
Conclusion
This study indicates that increasing cusp inclination by up to 10 degrees during endocrown fabrication may improve biomechanical performance in molars with limited remaining coronal tooth structure (≤ 1.5 mm above the CEJ). Such adjustment will enhance stress distribution without increasing shear stress at the adhesive interface. The findings support a customized occlusal design tailored to the residual anatomy; however, modifications should be kept within clinically acceptable limits that preserve functional occlusal anatomy, intercuspal stability, and esthetic harmony. While the study's strength lies in its controlled FEA approach, limitations include idealized environment and material assumptions. Further research under more clinically relevant conditions is recommended.
Conflict of Interest
None declared.
-
References
- 1 Tang W, Wu Y, Smales RJ. Identifying and reducing risks for potential fractures in endodontically treated teeth. J Endod 2010; 36 (04) 609-617
- 2 Dartora NR, de Conto Ferreira MB, Moris ICM. et al. Effect of intracoronal depth of teeth restored with endocrowns on fracture resistance: In-vitro and 3-dimensional finite element analysis. J Endod 2018; 44 (07) 1179-1185
- 3 Sedrez-Porto JA, Rosa WL, da Silva AF, Münchow EA, Pereira-Cenci T. Endocrown restorations: a systematic review and meta-analysis. J Dent 2016; 52: 8-14
- 4 Bindl A, Mörmann WH. Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years--preliminary results. J Adhes Dent 1999; 1 (03) 255-265
- 5 Hassouneh L, Jum'ah A, Ferrari M, Wood DJ. A micro-computed tomography analysis of marginal and internal fit of endocrowns fabricated from three CAD/CAM materials. Oper Dent 2023; 48 (01) 79-89
- 6 Rodrigues RF, Ramos CM, Francisconi PAS, Borges AFS. The shear bond strength of self-adhesive resin cements to dentin and enamel: an in vitro study. J Prosthet Dent 2015; 113 (03) 220-227
- 7 Hassouneh L, Jum'ah AA, Ferrari M, Wood DJ. Post-fatigue fracture resistance of premolar teeth restored with endocrowns: an in vitro investigation. J Dent 2020; 100: 103426
- 8 Tribst JPM, Dal Piva AMO, de Jager N, Bottino MA, de Kok P, Kleverlaan CJ. Full-crown versus endocrown approach: a 3D-analysis of both restorations and the effect of ferrule and restoration material. J Prosthodont 2021; 30 (04) 335-344
- 9 Govare N, Contrepois M. Endocrowns: a systematic review. J Prosthet Dent 2020; 123 (03) 411-418.e9
- 10 Rigolin FJ, Miranda ME, Flório FM, Basting RT. Evaluation of bond strength between leucite-based and lithium disilicate-based ceramics to dentin after cementation with conventional and self-adhesive resin agents. Acta Odontol Latinoam 2014; 27 (01) 16-24
- 11 Sasse M, Krummel A, Klosa K, Kern M. Influence of restoration thickness and dental bonding surface on the fracture resistance of full-coverage occlusal veneers made from lithium disilicate ceramic. Dent Mater 2015; 31 (08) 907-915
- 12 Dal Piva AMO, Tribst JPM, Borges ALS, Souza ROAE, Bottino MA. CAD-FEA modeling and analysis of different full crown monolithic restorations. Dent Mater 2018; 34 (09) 1342-1350
- 13 Khers SC, Carpenter CW, Vetter JD, Staley RN. Anatomy of cusps of posterior teeth and their fracture potential. J Prosthet Dent 1990; 64 (02) 139-147
- 14 Rosentritt M, Kolbeck C, Handel G, Schneider-Feyrer S, Behr M. Influence of the fabrication process on the in vitro performance of fixed dental prostheses with zirconia substructures. Clin Oral Investig 2011; 15 (06) 1007-1012
- 15 Lin J, Lin Z, Zheng Z. Effect of different restorative crown design and materials on stress distribution in endodontically treated molars: a finite element analysis study. BMC Oral Health 2020; 20 (01) 226
- 16 Pucci CR, Mafetano APVP, Borges ALS. et al. Substrate rigidity effect on CAD/CAM restorations at different thicknesses. Eur J Dent 2023; 17 (04) 1020-1028
- 17 Mathur VP, Atif M, Duggal I, Tewari N, Duggal R, Chawla A. Reporting guidelines for in-silico studies using finite element analysis in medicine (RIFEM). Comput Methods Programs Biomed 2022; 216: 106675
- 18 Hassouneh L, Matoug-Elwerfelli M, Al-Omari T, Setzer FC, Nagendrababu V. Assessment of biomechanical behavior of immature non-vital incisors with various treatment modalities by means of three-dimensional quasi-static finite element analysis. Sci Rep 2023; 13 (01) 17491
- 19 Abo-Alazm EAE, Abdou A, Hassouneh L, Safy RK. Reliability of an innovative slab shear versus microtensile bond strength test: mechanical and finite element analysis. Eur J Dent 2024; 18 (01) 182-195
- 20 Saber SM, Elashiry MM, Sadat SMAE, Nawar NN. A microcomputed tomographic analysis of the morphological variabilities and incidence of extra canals in mandibular first molar teeth in an Egyptian subpopulation. Sci Rep 2023; 13 (01) 8985
- 21 Wang Q, Liu Y, Wang Z. et al. Effect of access cavities and canal enlargement on biomechanics of endodontically treated teeth: a finite element analysis. J Endod 2020; 46 (10) 1501-1507
- 22 Abdelfattah RA, Nawar NN, Kataia EM, Saber SM. How loss of tooth structure impacts the biomechanical behavior of a single-rooted maxillary premolar: FEA. Odontology 2024; 112 (01) 279-286
- 23 Dimashkieh MR, Yousief SA, Demachkia AM. et al. Assessment of stress distribution around traditional and sleeve fixed partial denture designs: finite element analysis. Eur J Dent 2025; 19 (03) 667-677
- 24 Liu B, Lu C, Wu Y, Zhang X, Arola D, Zhang D. The effects of adhesive type and thickness on stress distribution in molars restored with all-ceramic crowns. J Prosthodont 2011; 20 (01) 35-44
- 25 Nawar NN, Elkholy MMA, Ha WN, Saber SM, Kim H-C. Optimum shaping parameters of the middle mesial canal in mandibular first molars: a finite element analysis study. J Endod 2023; 49 (05) 567-574
- 26 Nawar NN, Kataia M, Omar N, Kataia EM, Kim H-C. Biomechanical behavior and life span of maxillary molar according to the access preparation and pericervical dentin preservation: Finite element analysis. J Endod 2022; 48 (07) 902-908
- 27 Lise DP, Perdigão J, Van Ende A, Zidan O, Lopes GC. Microshear bond strength of resin cements to lithium disilicate substrates as a function of surface preparation. Oper Dent 2015; 40 (05) 524-532
- 28 Wan B, Chung BH, Zhang MR. et al. The effect of varying occlusal loading conditions on stress distribution in roots of sound and instrumented molar teeth: a finite element analysis. J Endod 2022; 48 (07) 893-901
- 29 Koc D, Dogan A, Bek B. Bite force and influential factors on bite force measurements: a literature review. Eur J Dent 2010; 4 (02) 223-232
- 30 Jansen van Vuuren L, Broadbent JM, Duncan WJ, Waddell JN. Maximum voluntary bite force, occlusal contact points and associated stresses on posterior teeth. J R Soc N Z 2020; 50 (01) 132-143
- 31 Plotino G, Grande NM, Isufi A. et al. Fracture strength of endodontically treated teeth with different access cavity designs. J Endod 2017; 43 (06) 995-1000
- 32 Aslan T, Esim E, Üstün Y, Dönmez Özkan H. Evaluation of stress distributions in mandibular molar teeth with different iatrogenic root perforations repaired with biodentine or mineral trioxide aggregate: a finite element analysis study. J Endod 2021; 47 (04) 631-640
- 33 Scotti N, Forniglia A, Tempesta RM. et al. Effects of fiber-glass-reinforced composite restorations on fracture resistance and failure mode of endodontically treated molars. J Dent 2016; 53: 82-87
- 34 Düzgün S, Esim E, Aslan T, Avcı ATE. Finite element analysis of stress in mandibular molars repaired after fractured instrument removal. BMC Oral Health 2025; 25 (01) 85
- 35 Saber SM, Hayaty DM, Nawar NN, Kim H-C. The effect of access cavity designs and sizes of root canal preparations on the biomechanical behavior of an endodontically treated mandibular first molar: a finite element analysis. J Endod 2020; 46 (11) 1675-1681
- 36 El Ghoul WA, Özcan M, Ounsi H, Tohme H, Salameh Z. Effect of different CAD-CAM materials on the marginal and internal adaptation of endocrown restorations: an in vitro study. J Prosthet Dent 2020; 123 (01) 128-134
- 37 Lee K-S, Shin J-H, Kim J-E. et al. Biomechanical evaluation of a tooth restored with high performance polymer PEKK post-core system: a 3D finite element analysis. BioMed Res Int 2017; 2017 (01) 1373127
- 38 Aslan T, Esim E, Üstün Y. Finite element evaluation of dentin stress changes following different endodontic surgical approaches. Odontology 2024; 112 (03) 798-810
- 39 Sira A, Nawar NN, Saber SM, Kim H-C. The effect of different separated file retrieval strategies on the biomechanical behavior of a mandibular molar: a finite element analysis study. J Endod 2024; 51 (01) 64-70
- 40 Özcan C, Lestriez P, Özcan M, Josset Y. Finite element analysis of dental structures: the role of mandibular kinematics and model complexity. Front Dent Med 2024; 5: 1461909
- 41 Shahmoradi M, Wan B, Zhang Z, Wilson T, Swain M, Li Q. Monolithic crowns fracture analysis: the effect of material properties, cusp angle and crown thickness. Dent Mater 2020; 36 (08) 1038-1051
Address for correspondence
Publikationsverlauf
Artikel online veröffentlicht:
07. August 2025
© 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)
Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
-
References
- 1 Tang W, Wu Y, Smales RJ. Identifying and reducing risks for potential fractures in endodontically treated teeth. J Endod 2010; 36 (04) 609-617
- 2 Dartora NR, de Conto Ferreira MB, Moris ICM. et al. Effect of intracoronal depth of teeth restored with endocrowns on fracture resistance: In-vitro and 3-dimensional finite element analysis. J Endod 2018; 44 (07) 1179-1185
- 3 Sedrez-Porto JA, Rosa WL, da Silva AF, Münchow EA, Pereira-Cenci T. Endocrown restorations: a systematic review and meta-analysis. J Dent 2016; 52: 8-14
- 4 Bindl A, Mörmann WH. Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years--preliminary results. J Adhes Dent 1999; 1 (03) 255-265
- 5 Hassouneh L, Jum'ah A, Ferrari M, Wood DJ. A micro-computed tomography analysis of marginal and internal fit of endocrowns fabricated from three CAD/CAM materials. Oper Dent 2023; 48 (01) 79-89
- 6 Rodrigues RF, Ramos CM, Francisconi PAS, Borges AFS. The shear bond strength of self-adhesive resin cements to dentin and enamel: an in vitro study. J Prosthet Dent 2015; 113 (03) 220-227
- 7 Hassouneh L, Jum'ah AA, Ferrari M, Wood DJ. Post-fatigue fracture resistance of premolar teeth restored with endocrowns: an in vitro investigation. J Dent 2020; 100: 103426
- 8 Tribst JPM, Dal Piva AMO, de Jager N, Bottino MA, de Kok P, Kleverlaan CJ. Full-crown versus endocrown approach: a 3D-analysis of both restorations and the effect of ferrule and restoration material. J Prosthodont 2021; 30 (04) 335-344
- 9 Govare N, Contrepois M. Endocrowns: a systematic review. J Prosthet Dent 2020; 123 (03) 411-418.e9
- 10 Rigolin FJ, Miranda ME, Flório FM, Basting RT. Evaluation of bond strength between leucite-based and lithium disilicate-based ceramics to dentin after cementation with conventional and self-adhesive resin agents. Acta Odontol Latinoam 2014; 27 (01) 16-24
- 11 Sasse M, Krummel A, Klosa K, Kern M. Influence of restoration thickness and dental bonding surface on the fracture resistance of full-coverage occlusal veneers made from lithium disilicate ceramic. Dent Mater 2015; 31 (08) 907-915
- 12 Dal Piva AMO, Tribst JPM, Borges ALS, Souza ROAE, Bottino MA. CAD-FEA modeling and analysis of different full crown monolithic restorations. Dent Mater 2018; 34 (09) 1342-1350
- 13 Khers SC, Carpenter CW, Vetter JD, Staley RN. Anatomy of cusps of posterior teeth and their fracture potential. J Prosthet Dent 1990; 64 (02) 139-147
- 14 Rosentritt M, Kolbeck C, Handel G, Schneider-Feyrer S, Behr M. Influence of the fabrication process on the in vitro performance of fixed dental prostheses with zirconia substructures. Clin Oral Investig 2011; 15 (06) 1007-1012
- 15 Lin J, Lin Z, Zheng Z. Effect of different restorative crown design and materials on stress distribution in endodontically treated molars: a finite element analysis study. BMC Oral Health 2020; 20 (01) 226
- 16 Pucci CR, Mafetano APVP, Borges ALS. et al. Substrate rigidity effect on CAD/CAM restorations at different thicknesses. Eur J Dent 2023; 17 (04) 1020-1028
- 17 Mathur VP, Atif M, Duggal I, Tewari N, Duggal R, Chawla A. Reporting guidelines for in-silico studies using finite element analysis in medicine (RIFEM). Comput Methods Programs Biomed 2022; 216: 106675
- 18 Hassouneh L, Matoug-Elwerfelli M, Al-Omari T, Setzer FC, Nagendrababu V. Assessment of biomechanical behavior of immature non-vital incisors with various treatment modalities by means of three-dimensional quasi-static finite element analysis. Sci Rep 2023; 13 (01) 17491
- 19 Abo-Alazm EAE, Abdou A, Hassouneh L, Safy RK. Reliability of an innovative slab shear versus microtensile bond strength test: mechanical and finite element analysis. Eur J Dent 2024; 18 (01) 182-195
- 20 Saber SM, Elashiry MM, Sadat SMAE, Nawar NN. A microcomputed tomographic analysis of the morphological variabilities and incidence of extra canals in mandibular first molar teeth in an Egyptian subpopulation. Sci Rep 2023; 13 (01) 8985
- 21 Wang Q, Liu Y, Wang Z. et al. Effect of access cavities and canal enlargement on biomechanics of endodontically treated teeth: a finite element analysis. J Endod 2020; 46 (10) 1501-1507
- 22 Abdelfattah RA, Nawar NN, Kataia EM, Saber SM. How loss of tooth structure impacts the biomechanical behavior of a single-rooted maxillary premolar: FEA. Odontology 2024; 112 (01) 279-286
- 23 Dimashkieh MR, Yousief SA, Demachkia AM. et al. Assessment of stress distribution around traditional and sleeve fixed partial denture designs: finite element analysis. Eur J Dent 2025; 19 (03) 667-677
- 24 Liu B, Lu C, Wu Y, Zhang X, Arola D, Zhang D. The effects of adhesive type and thickness on stress distribution in molars restored with all-ceramic crowns. J Prosthodont 2011; 20 (01) 35-44
- 25 Nawar NN, Elkholy MMA, Ha WN, Saber SM, Kim H-C. Optimum shaping parameters of the middle mesial canal in mandibular first molars: a finite element analysis study. J Endod 2023; 49 (05) 567-574
- 26 Nawar NN, Kataia M, Omar N, Kataia EM, Kim H-C. Biomechanical behavior and life span of maxillary molar according to the access preparation and pericervical dentin preservation: Finite element analysis. J Endod 2022; 48 (07) 902-908
- 27 Lise DP, Perdigão J, Van Ende A, Zidan O, Lopes GC. Microshear bond strength of resin cements to lithium disilicate substrates as a function of surface preparation. Oper Dent 2015; 40 (05) 524-532
- 28 Wan B, Chung BH, Zhang MR. et al. The effect of varying occlusal loading conditions on stress distribution in roots of sound and instrumented molar teeth: a finite element analysis. J Endod 2022; 48 (07) 893-901
- 29 Koc D, Dogan A, Bek B. Bite force and influential factors on bite force measurements: a literature review. Eur J Dent 2010; 4 (02) 223-232
- 30 Jansen van Vuuren L, Broadbent JM, Duncan WJ, Waddell JN. Maximum voluntary bite force, occlusal contact points and associated stresses on posterior teeth. J R Soc N Z 2020; 50 (01) 132-143
- 31 Plotino G, Grande NM, Isufi A. et al. Fracture strength of endodontically treated teeth with different access cavity designs. J Endod 2017; 43 (06) 995-1000
- 32 Aslan T, Esim E, Üstün Y, Dönmez Özkan H. Evaluation of stress distributions in mandibular molar teeth with different iatrogenic root perforations repaired with biodentine or mineral trioxide aggregate: a finite element analysis study. J Endod 2021; 47 (04) 631-640
- 33 Scotti N, Forniglia A, Tempesta RM. et al. Effects of fiber-glass-reinforced composite restorations on fracture resistance and failure mode of endodontically treated molars. J Dent 2016; 53: 82-87
- 34 Düzgün S, Esim E, Aslan T, Avcı ATE. Finite element analysis of stress in mandibular molars repaired after fractured instrument removal. BMC Oral Health 2025; 25 (01) 85
- 35 Saber SM, Hayaty DM, Nawar NN, Kim H-C. The effect of access cavity designs and sizes of root canal preparations on the biomechanical behavior of an endodontically treated mandibular first molar: a finite element analysis. J Endod 2020; 46 (11) 1675-1681
- 36 El Ghoul WA, Özcan M, Ounsi H, Tohme H, Salameh Z. Effect of different CAD-CAM materials on the marginal and internal adaptation of endocrown restorations: an in vitro study. J Prosthet Dent 2020; 123 (01) 128-134
- 37 Lee K-S, Shin J-H, Kim J-E. et al. Biomechanical evaluation of a tooth restored with high performance polymer PEKK post-core system: a 3D finite element analysis. BioMed Res Int 2017; 2017 (01) 1373127
- 38 Aslan T, Esim E, Üstün Y. Finite element evaluation of dentin stress changes following different endodontic surgical approaches. Odontology 2024; 112 (03) 798-810
- 39 Sira A, Nawar NN, Saber SM, Kim H-C. The effect of different separated file retrieval strategies on the biomechanical behavior of a mandibular molar: a finite element analysis study. J Endod 2024; 51 (01) 64-70
- 40 Özcan C, Lestriez P, Özcan M, Josset Y. Finite element analysis of dental structures: the role of mandibular kinematics and model complexity. Front Dent Med 2024; 5: 1461909
- 41 Shahmoradi M, Wan B, Zhang Z, Wilson T, Swain M, Li Q. Monolithic crowns fracture analysis: the effect of material properties, cusp angle and crown thickness. Dent Mater 2020; 36 (08) 1038-1051







