Abstract
Background: Use of the radial artery (RA) as a conduit in coronary artery bypass grafting (CABG)
has become increasingly popular in recent years. The aim of this study was to compare
the results of two different RA harvesting techniques. Use of the harmonic scalpel
is suggested to be safe and additionally reduces spasm rates. Material and Methods: From January 2000, the first 200 consecutive patients who underwent RA harvesting
for CABG were enrolled in this study. Patients were divided into two groups. RA was
harvested by means of electrocautery + hemoclips in Group I and by harmonic scalpel
+ hemoclips in Group II. 30 patients (30 %) in Group I and 25 patients (25 %) in Group
II were female. Mean age was 53.9 ± 9.3 and 53.5 ± 8.4 years in Group I and Group
II, respectively. Hand circulation and ulnar collateral flow was assured with a modified
Allen test in all patients preoperatively. During the operation perfusion of the hand
was monitored by oximetric plethysmography. The distal end of RA was also explored
and clamped with a soft vascular clamp to evaluate the saturation values in the groups.
During the clamping period, oxygen saturation values did not decrease so we harvested
RAs in all patients. Results: There were no statistically significant differences between the groups with the exception
of the RA harvesting times, the postoperative analgesia requirements, the rate of
vasospasm and the need for hemostatic clips. Conclusion: Harmonic scalpel usage in RA harvesting causes less trauma to adjacent tissues; the
analgesia requirements, the rate of vasospasm, the RA harvesting time and the need
of hemostatic clips decreases. We conclude that the use of a harmonic scalpel for
radial artery harvesting is safer and faster than the routine technique.
Key words
cardiovascular surgery - myocardial infarction - coronary bypass surgery
References
- 1
Chen A H, Nakao T, Brodman R F. et al .
Early postoperative angiographic assessment of radial artery grafts used for coronary
artery bypass grafting.
J Thorac Cardiovasc Surg.
1996;
111
1208-1212
- 2
Tatoulis J, Buxton B F, Fuller J A.
Bilateral radial artery grafts in coronary reconstruction: Technique and early results
in 261 patients.
Ann Thorac Surg.
1998;
66
714-719
- 3
Buxton B F, Fuller J A, Tatoulis J.
Evolution of complete arterial grafting for coronary artery disease.
Tex Heart Inst J.
1998;
25
17-23
- 4
Trick W E, Scheckler W E, Tokars J I. et al .
Risk factors for radial artery harvest site infection following coronary artery bypass
graft surgery.
Clin Infect Dis.
2000;
30
270-275
- 5
Sajja L R, Mannam G, Sompalli S.
Neurologic hand complications after radial artery harvest for coronary artery bypass
grafting.
J Thorac Cardiovasc Surg.
2002;
123
585-586
- 6
Galajda Z, Szentkiralyi I, Peterffy A.
Neurologic complications after radial artery harvesting.
J Thorac Cardiovasc Surg.
2002;
123
194-195
- 7
Meharwal Z S, Trehan N.
Functional status of the hand after radial artery harvesting: Results in 3977 cases.
Ann Thorac Surg.
2001;
72
1557-1561
- 8
Denton T A, Trento L, Cohen M. et al .
Radial artery harvesting for coronary bypass operations: Neurologic complications
and their potential mechanisms.
J Thorac Cardiovasc Surg.
2001;
121
951-956
- 9
Posacıoglu H, Atay Y, Cetindal B. et al .
Easy harvesting of radial artery with ultrasonically activated scalpel.
Ann Thorac Surg.
1998;
65
984-985
- 10
Higami T, Kozawa S, Asada T. et al .
Skeletonisation and harvest of the internal thoracic artery with an ultrasonic scalpel.
Ann Thorac Surg.
2000;
70
307-308
- 11
Wright C B, Barner H B, Gao A, Obial R, Bandy B, Perry L, Ronan J, Kelly C R.
The advantages of the harmonic scalpel for the harvesting of radial arteries for coronary
artery bypass.
Heart Surg Forum.
2001;
4
226-229
229-230
- 12
Georghiou G P, Stamler A, Berman M, Sharoni E, Vidne B A, Sahar G.
Advantages of the ultrasonic harmonic scalpel for radial artery harvesting.
Asian Cardiovasc Thorac Ann.
2005;
13
58-60
- 13
Ronan J W, Perry L A, Barner H B, Sundt 3rd T M.
Radial artery harvest: comparison of ultrasonic dissection with standard technique.
Ann Thorac Surg.
2000;
69
113-114
- 14
Chardigny C, Jebara V A, Acar C. et al .
Vasoreactivity of the radial artery. Comparison with the internal mammary and gastroepiploic
arteries with implications for coronary artery surgery.
Circulation.
1993;
88
115-127
- 15
Royse A G, Royse C F, Shah P. et al .
Radial artery harvest technique, use and functional outcome.
Eur J Cardiothorac Surg.
1999;
15
186-193
- 16
Lehtola A, Verkkala K, Jarvinen A.
Is electrocautery safe for internal mammary artery mobilisation? A study using scanning
electron microscopy.
Thorac Cardiovasc Surgeon.
1989;
37
55-57
- 17
Sudhakar C B, Forman D L, Dewar M L. et al .
Free radial artery grafts: Surgical technique and results.
Ann Plast Surg.
1999;
67
876-877
- 18
Ruengsakulrach P, Eizenberg N, Faher C. et al .
Surgical implications of variations in hand collateral circulation: Anatomy revisited.
J Thorac Cardiovasc Surg.
2001;
122
682-686
Dr. MD Bilgehan Savas Oz
Department of Cardiovascular Surgery
GATA - Gulhane Military Academy of Medicine
Kalp ve Damar Cerrahisi
Etlik 06018, Ankara
Turkey
Phone: + 90 31 23 04 52 42
Fax: + 90 31 23 04 52 00