Orthopedic Trauma Directions 2007; 5(3): 11-21
DOI: 10.1055/s-2007-980083
DOI: 10.1055/s-2007-980083
Clinical topic
© Georg Thieme Verlag Stuttgart · New York
Femoral shaft nonunions
Exchange nailing or plate fixationWeitere Informationen
Publikationsverlauf
Publikationsdatum:
22. Juni 2007 (online)

Summary
Evidence from nine case series suggests rates of solid union may be lower and the complication frequency higher for exchange nailing of femoral shaft nonunions than with plate fixation. However, no comparative study was found to evaluate the efficacy and safety of these procedures and there were more series describing exchange nailing than plate fixation. Methodologically rigorous comparative studies with larger populations are necessary to establish the long term safety and efficacy of these two operative treatments and to evaluate the superiority of one treatment over another.