Z Orthop Unfall 2007; 145: S44-S48
DOI: 10.1055/s-2007-965660
Original Article

© Georg Thieme Verlag KG Stuttgart · New York

Revision Surgery in High Grade Acetabular Defects with Thermodisinfected Allografts

R. Volkmann1 , K. Bretschneider1 , E. Erlekampf1 , S. Weller2
  • 1Department for Trauma Surgery and Orthopaedics, Hospital Bad Hersfeld, Germany
  • 2Tübingen, Germany
Further Information

Publication History

Publication Date:
16 October 2007 (online)

Abstract

Aim: Due to new medical knowledge and legal restrictions, it is increasingly difficult to run a traditional allogenic bone bank so that alternative bone substitutes and methods of processing are being sought worldwide. Method: In a prospective clinical study, the biological efficacy of thermodisinfected and then cryopreserved allogenic bank bone was investigated in 19 acetabular revisions in 18 patients. Simultaneously a newly developed titanium reconstruction ring was used. Any revision was regarded as an end point and the follow-up with radiological and clinical results were recorded. Results: The mean follow-up period was 8.1 (7.9 - 9.8) years. The patients were 73.5 years old (46 - 91) at the time of the revision surgery. One case had a septic course necessitating revision surgery. The other cases showed increasing homogeneity compared to the opposite side and gradual adaptation to the radiological structures found there beforehand. Screw breakage was observed in 3 cases but no implant failure, migration tendency or change in the position of the reconstruction ring or PE‐cup. Conclusion: Despite the low case numbers and different baseline situations, it can be concluded that thermodisinfected cancellous bone chips enable similarly good acetabular reconstruction as the routinely tried and tested cryoconserved, non-processed bone bank allograft, which is becoming increasingly difficult to obtain because of altered guidelines and legislation. The newly developed reconstruction ring has proven itself because of the improved range of sizes and the possibility of adjustment to the anatomical circumstances together with its outstanding material characteristics in clinical use.

References

  • 1 Bader R, Mittelmeier W, Zeiler G, Trokar I, Steinhauser E, Schuh A. Pitfalls in the use of acetabular reinforcement rings in total hip revision.  Arch Orthop Trauma Surg. 2005;  125 553-563
  • 2 Bettin D, Katthagen B-D. [The German Society of Orthopedics and Traumatology classification of bone defects in total hip endoprostheses revision operations] Die DGOT-Klassifikation von Knochendefekten bei Hüft-Totalendoprothesen-Revisionsoperationen.  Z Orthop. 1997;  135 281-284
  • 3 Bolder S B, Verdonschot N, Schreurs B W. Technical factors affecting cup stability in bone impaction grafting.  Proc Inst Mech Eng. 2007;  221 81-86
  • 4 Knaepler H, v Garrel T, Seipp H M, Ascherl R, Gotzen L. Autoklavierung von allogenen Knochentransplantaten als Alternative zur konventionellen Knochenbank?.  Orthop Praxis. 1992;  28 18-22
  • 5 Lie S A, Havelin L I, Engesaeter L B. et al . Failure rates for 4762 revision total hip arthroplasties in the Norwegian Arthroplasty Register.  J Bone Joint Surg [Br]. 2004;  86 504-509
  • 6 Piriou P, Sagnet F, Norton M R, de Loubress C G, Judet T. Acetabular component revision with frozen massive structural pelvic allograft: average 5-year follow-up.  J Arthroplasty. 2003;  18 562-569
  • 7 Schlegel U J, Bitsch R G, Pritsch M, Mau H, Breusch S J. Mueller reinforcement rings in acetabular revision: outcome in 164 hips for 2 - 17 ears.  Acta Orthop. 2006;  77 234-241
  • 8 Volkmann R, Maurer F, Eingartner C, Weller S. [Primary total endoprosthetic hip joint replacement in acetabulum fractures] Primärer totalendoprothetischer Hüftgelenkersatz bei Acetabulumfrakturen.  Unfallchirurgie. 1995;  21 292-297
  • 9 Wagner H. [A revision prosthesis for the hip joint] Revisionsprothese für das Hüftgelenk.  Orthopäde. 1989;  18 438-453
  • 10 Winter E, Piert S, Volkmann R, Maurer F, Eingartner C, Weise K, Weller S. Allogenic cancellous bone graft and a Burch-Schneider ring for acetabular reconstruction in revision hip arthroplasty.  J Bone Joint Surg [Am]. 2001;  83 862-867

PD Dr. MD Rüdiger Volkmann

Klinik für Unfallchirurgie und Orthopädie
Klinikum Bad Hersfeld GmbH

Seilerweg 29

36251 Bad Hersfeld

Germany

Phone: + 49 62 21 88 15 71

Fax: + 49 62 21 88 15 60

Email: ruediger.volkmann@klinikum-hef.de

    >