CC BY 4.0 · Surg J (N Y) 2022; 08(04): e279-e282
DOI: 10.1055/s-0042-1757603
Case Report

Intraluminal Migration of a Penrose Drain Presented with Hematochezia, after Lower Gastrointestinal Surgery

1   2nd Department of General Surgery, 417 Army Share Fund Hospital, Athens, Greece
,
2   Department of Gastroenterology, 401 Army General Hospital, Athens, Greece
,
3   Department of Nursing, School of Health Sciences, Hellenic Mediterranean University, Athens, Greece
,
4   2nd Department of General Surgery, 401 Army General Hospital, Athens, Greece
› Author Affiliations
Funding No funding was needed for this study.

Abstract

Background Although surgical drains are widely used after lower gastrointestinal (GI) procedures, complications may occur. Specifically, sporadic cases of drain migration into a hollow viscus, most commonly regarding active drains and treated with surgical removal, have been reported. Herein, we present a case of a passive drain (penrose) migration into the colon, after segmental sigmoidectomy with primary anastomosis, presented with hematochezia.

Methods A 37-year-old male patient suffering from colovesical fistula, due to sigmoid diverticulitis, underwent resection of the fistula, the involved sigmoid segment and the bladder opening, followed by primary anastomosis of the colon and primary closure of the bladder. A penrose catheter was positioned near the anastomosis.

Results On 8th postoperative day (POD) the patient had three episodes of hematochezia and blood in the drain collection bag, followed by relative improvement. On 15th POD gas was observed on the drain's collection bag and a new episode of hematochezia led him to sigmoidoscopy. The endoscopy revealed the presence of the penrose drain intraluminally, protruding via an ulcer at the level of the anastomosis. The penrose repositioned outside the lumen and metallic clips were used to approximate the defect. The patient was then fully recovered, discharged, and the drain removed on follow-up.

Conclusion To our knowledge this is the first report of drain migration presented with hematochezia, after lower GI surgery, avoided reoperation, and resolved with removal of the drain under direct endoscopic vision.



Publication History

Received: 19 January 2022

Accepted: 20 May 2022

Article published online:
10 October 2022

© 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Durai R, Ng PC. Surgical vacuum drains: types, uses, and complications. AORN J 2010; 91 (02) 266-271 , quiz 272–274
  • 2 Yılmaz KB, Akıncı M, Şeker D, Güller M, Güneri G, Kulaçoğlu H. Factors affecting the safety of drains and catheters in surgical patients. Ulus Cerrahi Derg 2014; 30 (02) 90-92
  • 3 Risher WH, McKinnon WM. Foreign body in the gastrointestinal tract: intraluminal migration of laparotomy sponge. South Med J 1991; 84 (08) 1042-1045
  • 4 Dhillon JS, Park A. Transmural migration of a retained laparotomy sponge. Am Surg 2002; 68 (07) 603-605
  • 5 Steinhagen E, Khaitov S, Steinhagen RM. Intraluminal migration of mesh following incisional hernia repair. Hernia 2010; 14 (06) 659-662
  • 6 Polychronidis A, Karayiannakis AJ, Perente S, Botaitis S, Simopoulos C. Enteral migration of a Pezzer tube after a feeding jejunostomy: report of a case. Surg Today 2003; 33 (08) 620-622
  • 7 Bose AC, Shankar RR, Kate V, Ananthakrishnan N. Spontaneous antegrade enteral migration of feeding jejunostomy tube. Indian J Gastroenterol 2005; 24 (02) 74
  • 8 Prahlow JA, Barnard JJ. Jejunostomy tube failure: malnutrition caused by intraluminal antegrade jejunostomy tube migration. Arch Phys Med Rehabil 1998; 79 (04) 453-455
  • 9 Mittermair RP, Weiss H, Nehoda H, Aigner F. Uncommon intragastric migration of the Swedish adjustable gastric band. Obes Surg 2002; 12 (03) 372-375
  • 10 Hak DJ. Retained broken wound drains: a preventable complication. J Orthop Trauma 2000; 14 (03) 212-213
  • 11 Agrawal A, Avill R. Mesh migration following repair of inguinal hernia: a case report and review of literature. Hernia 2006; 10 (01) 79-82
  • 12 Celik A, Kutun S, Kockar C, Mengi N, Ulucanlar H, Cetin A. Colonoscopic removal of inguinal hernia mesh: report of a case and literature review. J Laparoendosc Adv Surg Tech A 2005; 15 (04) 408-410
  • 13 Wilmot AS, Levine MS, Rubesin SE, Kucharczuk JC, Laufer I. Intraluminal migration of surgical drains after transhiatal esophagogastrectomy: radiographic findings and clinical relevance. AJR Am J Roentgenol 2007; 189 (04) 780-785
  • 14 Lai PS, Lo C, Lin LW, Lee PC. Drain tube migration into the anastomotic site of an esophagojejunostomy for gastric small cell carcinoma: short report. BMC Gastroenterol 2010; 10: 50
  • 15 Narendra N, Sandar N, Jhagroo G, Anand S. Intraluminal migration of a Jackson-Pratt drain: an unusual complication of gastric bypass surgery. Am J Gastroenterol 2009; 104: S381
  • 16 Nomura T, Shirai Y, Okamoto H, Hatakeyama K. Bowel perforation caused by silicone drains: a report of two cases. Surg Today 1998; 28 (09) 940-942
  • 17 Subhash R, Ali IV, Natesh B. Intraluminal migration of drain tube: a short report. Ann Gastroenterol 2013; 26 (01) 93-95
  • 18 Micalef A, Polizzi M, Bondurri A, Maffioli A, Danelli P. Intra-luminal migration of a laminar penrose drain a case report and literature review. Open J Surg Case Reports. 2020; (01) 22-24
  • 19 Gray AJ, Copeland GP. Small bowel perforation following vacuum suction drainage. J R Coll Surg Edinb 1985; 30 (05) 324-325
  • 20 Carlomagno N, Santangelo ML, Grassia S, La Tessa C, Renda A. Intraluminal migration of a surgical drain. Report of a very rare complication and literature review. Ann Ital Chir 2013; 84 (02) 219-223