Am J Perinatol 2024; 41(S 01): e3133-e3139
DOI: 10.1055/a-2196-6469
Original Article

The Correlation between Fetal Monitor Decelerations Area and Neonatal Cord pH among Preeclamptic parturient: an Automated Approach to a Clinical Challenge

1   Department of Obstetrics and Gynecology, Shaare Zedek Medical Center, Jerusalem, Israel
,
Ella Theodor
2   Department of Obstetrics and Gynecology, Faculty of Health Sciences, Soroka University Medical Center, Ben-Gurion University of the Negev, Beer-Sheva, Israel
,
Ayala Hirsch
1   Department of Obstetrics and Gynecology, Shaare Zedek Medical Center, Jerusalem, Israel
,
1   Department of Obstetrics and Gynecology, Shaare Zedek Medical Center, Jerusalem, Israel
,
Shimrit Y. Salem
2   Department of Obstetrics and Gynecology, Faculty of Health Sciences, Soroka University Medical Center, Ben-Gurion University of the Negev, Beer-Sheva, Israel
,
Adi Y. Weintraub
2   Department of Obstetrics and Gynecology, Faculty of Health Sciences, Soroka University Medical Center, Ben-Gurion University of the Negev, Beer-Sheva, Israel
› Author Affiliations
Funding None.

Abstract

Objective To examine whether a correlation exists between electronic fetal monitoring (EFM) in the final 120 minute prior to delivery and neonatal cord blood pH among parturients with preeclampsia.

Study Design A retrospective cohort study of parturients with term and near-term preeclampsia who delivered at Soroka University Medical Center between 2013 and 2020 was conducted. EFM tracings, demographical data, and obstetrical outcomes were retrieved from the patients' electronic medical records. Using MATLAB program, area under the curve (AUC) measurements were applied. Correlation was calculated using the Spearman's correlation coefficient.

Results EFM of 88 parturients with preeclampsia were assessed. A significant negative correlation was demonstrated between cord blood pH and the decelerations AUC, total decelerations duration, and deceleration depth. No correlation was demonstrated between area over the curve (acceleration) and cord blood pH. In a multivariate linear regression, total deceleration AUC was found independently negatively associated with cord blood pH (beta = −0.264, p = 0.011) controlling for second stage of labor duration and induction of labor.

Conclusion Among parturients with preeclampsia, EFM indices may assist in the diagnosis of fetal acidemia. Further studies are needed to strengthen and establish the use of electronic EFM in the management of labor and delivery.

Key Points

  • A negative correlation was demonstrated between cord blood pH and the decelerations AUC.

  • Total deceleration AUC was found independently negatively associated.

  • Among parturients with preeclampsia, EFM indices may assist in the diagnosis of fetal acidemia.

Ethical Approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. For this type of study, formal consent is not required. This article does not contain any studies with animals performed by any of the authors. The Soroka Medical Center Institutional Review Board approved the study, with waiver of informed consent due to the retrospective, observational design of the study.


Supplementary Material



Publication History

Received: 25 July 2023

Accepted: 18 October 2023

Accepted Manuscript online:
23 October 2023

Article published online:
14 November 2023

© 2023. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Andres RL, Saade G, Gilstrap LC. et al. Association between umbilical blood gas parameters and neonatal morbidity and death in neonates with pathologic fetal acidemia. Am J Obstet Gynecol 1999; 181 (04) 867-871
  • 2 Ruis KA, Ruis KA, Lehmann CU, Northington FJ, Lin DD, Graham EM. Neonatal brain imaging and the identification of metabolic acidemia and hypoxic-ischemic encephalopathy. J Matern Fetal Neonatal Med 2009; 22 (10) 823-828
  • 3 Sabol BA, Caughey AB. Acidemia in neonates with a 5-minute Apgar score of 7 or greater - what are the outcomes?. Am J Obstet Gynecol 2016; 215 (04) 486.e1-486.e6
  • 4 Martí Gamboa S, Lapresta Moros M, Pascual Mancho J, Lapresta Moros C, Castán Mateo S. Deceleration area and fetal acidemia. J Matern Fetal Neonatal Med 2017; 30 (21) 2578-2584
  • 5 Coletta J, Murphy E, Rubeo Z, Gyamfi-Bannerman C. The 5-tier system of assessing fetal heart rate tracings is superior to the 3-tier system in identifying fetal acidemia. Am J Obstet Gynecol 2012; 206 (03) 226.e1-226.e5
  • 6 American College of Obstetricians and Gynecologists. Practice bulletin no. 116: management of intrapartum fetal heart rate tracings. Obstet Gynecol 2010; 116 (05) 1232-1240
  • 7 American College of Obstetricians and Gynecologists (ACOG). Practice Bulletin no. 222: gestational hypertension and preeclampsia. Obstet Gynecol 2020; 135: e237-e260
  • 8 Myers JE, Kenny LC, McCowan LME. et al; SCOPE Consortium. Angiogenic factors combined with clinical risk factors to predict preterm pre-eclampsia in nulliparous women: a predictive test accuracy study. BJOG 2013; 120 (10) 1215-1223
  • 9 Mol BW, Roberts CT, Thangaratinam S, Magee LA, De Groot CJ, Hofmeyr GJ. Pre-eclampsia. The Lancet 2016; Mar 5; 387 (10022): 999-1011
  • 10 Cahill AG, Tuuli MG, Stout MJ, López JD, Macones GA. A prospective cohort study of fetal heart rate monitoring: deceleration area is predictive of fetal acidemia. Am J Obstet Gynecol 2018; 218 (05) 523.e1-523.e12
  • 11 Kundu S, Kuehnle E, Schippert C, von Ehr J, Hillemanns P, Staboulidou I. Estimation of neonatal outcome artery pH value according to CTG interpretation of the last 60 min before delivery: a retrospective study. Can the outcome pH value be predicted?. Arch Gynecol Obstet 2017; 296 (05) 897-905
  • 12 Itskovitz J, LaGamma EF, Rudolph AM. Heart rate and blood pressure responses to umbilical cord compression in fetal lambs with special reference to the mechanism of variable deceleration. Am J Obstet Gynecol 1983; 147 (04) 451-457
  • 13 Jackson M, Holmgren CM, Esplin MS, Henry E, Varner MW. Frequency of fetal heart rate categories and short-term neonatal outcome. Obstet Gynecol 2011; 118 (04) 803-808
  • 14 Backes CH, Markham K, Moorehead P, Cordero L, Nankervis CA, Giannone PJ. Maternal preeclampsia and neonatal outcomes. J Pregnancy 2011; 2011: 214365
  • 15 Lear CA, Galinsky R, Wassink G. et al. The myths and physiology surrounding intrapartum decelerations: the critical role of the peripheral chemoreflex. J Physiol 2016; 594 (17) 4711-4725
  • 16 Gyllencreutz E, Lu K, Lindecrantz K. et al. Validation of a computerized algorithm to quantify fetal heart rate deceleration area. Acta Obstet Gynecol Scand 2018; 97 (09) 1137-1147
  • 17 Gyllencreutz E, Varli IH, Lindqvist PG, Holzmann M. Variable deceleration features and intrapartum fetal acidemia - the role of deceleration area. Eur J Obstet Gynecol Reprod Biol 2021; 267: 192-197
  • 18 Talmor M, Rotem R, Wientraub AY, Yaniv Salem S. The correlation between total deceleration and acceleration surface areas on electronic fetal monitoring and neonatal cord blood pH in postdate pregnancies. Int J Gynaecol Obstet 2023; 161 (03) 870-876
  • 19 Miranda ML, Edwards SE, Myers ER. Adverse birth outcomes among nulliparous vs. multiparous women. Public Health Rep 2011; 126 (06) 797-805
  • 20 Dekker GA, Robillard PY, Hulsey TC. Immune maladaptation in the etiology of preeclampsia: a review of corroborative epidemiologic studies. Obstet Gynecol Surv 1998; 53 (06) 377-382
  • 21 Holzmann M, Wretler S, Nordström L. Absence of accelerations during labor is of little value in interpreting fetal heart rate patterns. Acta Obstet Gynecol Scand 2016; 95 (10) 1097-1103
  • 22 Trochez RD, Sibanda T, Sharma R, Draycott T. Fetal monitoring in labor: are accelerations good enough?. J Matern Fetal Neonatal Med 2005; 18 (05) 349-352
  • 23 North RA, McCowan LM, Dekker GA. et al. Clinical risk prediction for pre-eclampsia in nulliparous women: development of model in international prospective cohort. BMJ 2011; 342: d1875
  • 24 Esteban-Escaño J, Castán B, Castán S. et al. Machine learning algorithm to predict acidemia using electronic fetal monitoring recording parameters. Entropy (Basel) 2021; 24 (01) 68
  • 25 Zhao Z, Deng Y, Zhang Y, Zhang Y, Zhang X, Shao L. DeepFHR: intelligent prediction of fetal acidemia using fetal heart rate signals based on convolutional neural network. BMC Med Inform Decis Mak 2019; 19 (01) 286
  • 26 Goodfellow I, Bengio Y, Courvile A. Deep Learning (Adaptive Computation and Machine Learning Series). Cambridge, MA: The MIT Press; . ISBN 978–0-262–33737–3; 2016