Endoscopy 2021; 53(09): 937-940
DOI: 10.1055/a-1302-2942
Innovations and brief communications

Benchmarking definitions of false-positive alerts during computer-aided polyp detection in colonoscopy

Authors

  • Erik A. Holzwanger

    1   Division of Gastroenterology and Hepatology, Tufts Medical Center, Boston, Massachusetts, United States
  • Mohammad Bilal

    2   Center for Advanced Endoscopy, Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, United States
  • Jeremy R. Glissen Brown

    2   Center for Advanced Endoscopy, Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, United States
  • Shailendra Singh

    3   West Virginia University Health Sciences Center Charleston Division, Charleston, West Virginia, United States
  • Aymeric Becq

    4   Sorbonne Université, Centre d’Endoscopie Digestive, Hôpital Saint Antoine, APHP, Paris, France
  • Kenneth Ernest-Suarez

    5   Gastroenterology Department, Hospital México, University of Costa Rica, San Jose, Costa Rica
  • Tyler M. Berzin

    2   Center for Advanced Endoscopy, Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, United States
Preview

Abstract

Background The occurrence of false-positive alerts is an important outcome measure in computer-aided colon polyp detection (CADe) studies. However, there is no consensus definition of a false positive in clinical trials evaluating CADe in colonoscopy. We aimed to study the diagnostic performance of CADe based on different threshold definitions for false-positive alerts.

Methods A previously validated CADe system was applied to screening/surveillance colonoscopy videos. Different thresholds for false-positive alerts were defined based on the time an alert box was continuously traced by the system. Primary outcomes were false-positive results and specificity using different threshold definitions of false positive.

Results 62 colonoscopies were analyzed. CADe specificity and accuracy were 93.2 % and 97.8 %, respectively, for a threshold definition of ≥ 0.5 seconds, 98.6 % and 99.5 % for a threshold definition of ≥ 1 second, and 99.8 % and 99.9 % for a threshold definition of ≥ 2 seconds.

Conclusion Our analysis demonstrated how different threshold definitions of false positive can impact the reported diagnostic performance of CADe for colon polyp detection.



Publikationsverlauf

Eingereicht: 26. Mai 2020

Angenommen: 02. November 2020

Accepted Manuscript online:
02. November 2020

Artikel online veröffentlicht:
18. Januar 2021

© 2020. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany