CC BY-NC-ND 4.0 · Endosc Int Open 2019; 07(11): E1327-E1332
DOI: 10.1055/a-0957-3005
Original article
Owner and Copyright © Georg Thieme Verlag KG 2019

Does endoscopic ultrasound-guided fine needle biopsy using a Franseen needle really offer high diagnostic accuracy? A propensity-matched analysis

Akashi Fujita
1   Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
,
Shomei Ryozawa
1   Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
,
Masafumi Mizuide
1   Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
,
Ryuichiro Araki
2   Community Health Science Center, Saitama Medical University, Saitama, Japan
,
Koji Nagata
3   Department of Pathology, Saitama Medical University International Medical Center, Saitama, Japan
,
Yuki Tanisaka
1   Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
,
Maiko Harada
1   Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
,
Tomoya Ogawa
1   Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
,
Tomoaki Tashima
1   Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
,
Kouichi Nonaka
1   Department of Gastroenterology, Saitama Medical University International Medical Center, Saitama, Japan
› Author Affiliations
Further Information

Publication History

submitted 05 March 2019

accepted after revision 09 May 2019

Publication Date:
22 October 2019 (online)

Abstract

Background and study aims This study aimed to investigate the diagnostic accuracy and utility of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) performed using a Franseen needle on solid pancreatic lesions.

Patients and methods This study included 132 consecutive lesions sampled by endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) using a 22-G conventional needle and 95 consecutive lesions evaluated by EUS-FNB using a 22-G Franseen needle to evaluate solid pancreatic lesions at our medical center between July 2013 and November 2018. We used propensity-matched analysis with adjustment for confounders. Patient data were analyzed retrospectively.

Results Diagnostic accuracy was higher in the Franseen needle group (Group F; 91.6 %, 87 /95) than in the conventional needle group (Group C; 86.3 %, 82 /95), showing no significant difference (P = 0.36). In Group F, diagnostic accuracies for pancreatic head lesions and lesions sampled by transduodenal puncture were 98.0 % (48/49) and 97.9 % (46/47), respectively. These values were significantly higher than values in Group C (P = 0.013, 0.01). Group F displayed a significantly lower number of punctures. In terms of differentiating benign from malignant lesions, Group C showed 85.1 % sensitivity (74/87), 100 % specificity (8/8), 100 % positive predictive value (74/74), and 38.1 % negative predictive value (8/21), compared to values of 90.1 % (73/81), 100 % (14/14), 100 % (73/73), and 63.6 % (14/22), respectively, in Group F. Sensitivity and negative predictive value were better in Group F.

Conclusions Franseen needles for EUS-FNB of solid pancreatic lesions offer similar puncture performance at different lesion sites while requiring fewer punctures than conventional needles.

 
  • References

  • 1 Vilmann P, Jacobsen GK, Henriksen FW. et al. Endoscopic ultrasonography with guided fine needle aspiration biopsy in pancreatic disease. Gastrointest Endosc 1992; 38: 172-173
  • 2 Haba S, Yamao K, Bhatia V. et al. Diagnostic ability and factors affecting accuracy of endoscopic ultrasound-guided fine needle aspiration for pancreatic solid lesions: Japanese large single center experience. J Gastroenterol 2013; 48: 973-981
  • 3 Mekky MA, Yamao K, Sawaki A. et al. Diagnostic utility of EUS-guided FNA in patients with gastric submucosal tumors. Gastrointest Endosc 2010; 71: 913-919
  • 4 Yasuda I, Tsurumi H, Omar S. et al. Endoscopic ultrasound-guided fine-needle aspiration biopsy for lymphadenopathy of unknown origin. Endoscopy 2006; 38: 919-924
  • 5 Hewitt MJ, McPhail MJ, Possamai L. et al. EUS-guided FNA for diagnosis of solid pancreatic neoplasms: a meta-analysis. Gastrointestinal endoscopy 2012; 75: 319-331
  • 6 Iglesias-Garcia J, Dominguez-Munoz JE, Abdulkader I. et al. Influence of on-site cytopathology evaluation on the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid pancreatic masses. The American journal of gastroenterology 2011; 106: 1705-1710
  • 7 Madhoun MF, Wani SB, Rastogi A. et al. The diagnostic accuracy of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of solid pancreatic lesions: a meta-analysis. Endoscopy 2013; 45: 86-92
  • 8 Mukai S, Itoi T, Yamaguchi H. et al. A retrospective histological comparison of EUS-guided fine-needle biopsy using a novel franseen needle and a conventional end-cut type needle. Endoscopic Ultrasound 2019; 8: 50-57
  • 9 Iwashita T, Yasuda I, Doi S. et al. Use of samples from endoscopic ultrasound-guided 19-gauge fine-needle aspiration in diagnosis of autoimmune pancreatitis. Clin Gastroenterol Hepatol 2012; 10: 316-322
  • 10 Yasuda I, Goto N, Tsurumi H. et al. Endoscopic ultrasound-guided fine needle aspiration biopsy for diagnosis of lymphoproliferative disorders: feasibility of immunohistological, flow cytometric, and cytogenetic assessments. Am J Gastroenterol 2012; 107: 397-404
  • 11 Lee YN, Moon JH, Kim HK. et al. Core biopsy needle versus standard aspiration needle for endoscopic ultrasound-guided sampling of solid pancreatic masses: a randomized parallel-group study. Endoscopy 2014; 46: 1056-1062
  • 12 Lin M, Hair CD, Green LK. et al. Endoscopic ultrasound-guided fine-needle aspiration with on-site cytopathology versus core biopsy: a comparison of both techniques performed at the same endoscopic session. Endosc Int Open 2014; 2: E220-223
  • 13 Bang JY, Hebert-Magee S, Navaneethan U. et al. Randomized trial comparing the Franseen and Fork-tip needles for EUS-guided fine-needle biopsy sampling of solid pancreatic mass lesions. Gastrointest Endosc 2018; 87: 1432-1438
  • 14 Bang JY, Hawes R, Varadarajulu S. A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition. Endoscopy 2016; 48: 339-349
  • 15 Bang JY, Hebert-Magee S, Hasan MK. et al. Endoscopic ultrasonography-guided biopsy using a Franseen needle design: initial assessment. Dig Endosc 2017; 29: 338-346
  • 16 Fujita A, Ryozawa S, Kobayashi M. et al. Diagnostic ability of a 22G Franseen needle in endoscopic ultrasound-guided fine needle aspiration of subepithelial lesions. Mol Clin Oncol 2018; 9: 527-531
  • 17 Mukai S, Itoi T, Ashida R. et al. Multicenter, prospective, crossover trial comparing the door-knocking method with the conventional method for EUS-FNA of solid pancreatic masses (with videos). Gastrointest Endosc 2016; 83: 1210-1217
  • 18 Iwashita T, Yasuda I, Mukai T. et al. Macroscopic on-site quality evaluation of biopsy specimens to improve the diagnostic accuracy during EUS-guided FNA using a 19-gauge needle for solid lesions: a single-center prospective pilot study (MOSE study). Gastrointest Endosc 2015; 81: 177-185
  • 19 Ashida R, Nakata B, Shigekawa M. et al. Gemcitabine sensitivity-related mRNA expression in endoscopic ultrasound-guided fine-needle aspiration biopsy of unresectable pancreatic cancer. J Exp Clin Cancer Res 2009; 28: 83
  • 20 Ogura T, Yamao K, Hara K. et al. Prognostic value of K-ras mutation status and subtypes in endoscopic ultrasound-guided fine-needle aspiration specimens from patients with unresectable pancreatic cancer. J Gastroenterol 2013; 48: 640-646
  • 21 Ryozawa S, Iwano H, Taba K. et al. Genetic diagnosis of pancreatic cancer using specimens obtained by EUS-FNA. Dig Endosc 2011; 23 (Suppl. 01) 43-45
  • 22 Zagouri F, Sergentanis TN, Chrysikos D. et al. Molecularly targeted therapies in metastatic pancreatic cancer: a systematic review. Pancreas 2013; 42: 760-773
  • 23 Leung Ki EL, Lemaistre AI, Fumex F. et al. Macroscopic onsite evaluation using endoscopic ultrasound fine needle biopsy as an alternative to rapid onsite evaluation. Endosc Int Open 2019; 7: E189-E194
  • 24 Ishikawa T, Kawashima H, Ohno E. et al. Clinical Impact of EUS-guided fine needle biopsy using a novel Franseen needle for histological assessment of pancreatic diseases. Can J Gastroenterol Hepatol 2019; 2019: 8581743