Endoscopy 2021; 53(02): E69-E70
DOI: 10.1055/a-1193-4359
E-Videos

Salvage endoscopic ultrasound-guided stent placement into a stent that had migrated into the peritoneum during a hepaticogastrostomy procedure

Miruna Cruceru
1   Department of Endoscopy and Gastroenterology, Edouard Herriot Hospital, Lyon, France
,
Marianna Milashka
1   Department of Endoscopy and Gastroenterology, Edouard Herriot Hospital, Lyon, France
,
Florian Rostain
1   Department of Endoscopy and Gastroenterology, Edouard Herriot Hospital, Lyon, France
,
Mickaël Mochet
1   Department of Endoscopy and Gastroenterology, Edouard Herriot Hospital, Lyon, France
,
Maxime Delvincourt
1   Department of Endoscopy and Gastroenterology, Edouard Herriot Hospital, Lyon, France
,
Jérémie Jacques
2   Department of Endoscopy and Gastroenterology, Dupuytren Hospital, Limoges, France
,
Mathieu Pioche
2   Department of Endoscopy and Gastroenterology, Dupuytren Hospital, Limoges, France
3   INSERM U1032, LabTau, Lyon, France
› Author Affiliations

Hepaticogastrostomy has become a standard procedure for biliary obstruction when endoscopic retrograde cholangiopancreatography (ERCP) is not feasible. Nevertheless, it remains challenging and stent migration into the peritoneum is a well-known complication, occurring in 2.7 % of cases [1], and possibly leading to death [2].

Different salvage techniques have been reported to pull the stent back into the stomach using either a cholangioscope through the gastric hole [3] or natural orifice transluminal endoscopic surgery [4] [5].

We report the case of a 78-year-old woman with a pancreatic cystic adenocarcinoma initially invading the duodenum. Duodenal obstruction was treated by surgical gastroenterostomy. One month later, the patient was referred for biliary drainage under endoscopic ultrasound guidance by hepaticogastrostomy because ERCP was impossible.

After puncturing the left bile duct with a 19-gauge needle and an 8.5-Fr cystotome, a dedicated 8-cm, half-covered self-expandable metal stent (SEMS; Hanarostent; Life Partners Europe, Bagnolet, France) was introduced into the left liver. The stent was accidentally deployed too fast and migrated into the peritoneal cavity outside the stomach. We failed to catch the stent with forceps through the gastric hole. We used EUS to detect the stent in the peritoneal cavity ([Fig. 1], [Video 1]) and then punctured the stent lumen with the 19-gauge needle for guidewire placement within the stent. The guidewire was pushed into the common bile duct and an 8-cm covered SEMS was placed to make a bridge between the migrated stent and the gastric lumen ([Fig. 2]). Fluoroscopic control with contrast revealed no leakage and the patient did not experience peritonitis during follow-up.

Zoom Image
Fig. 1 Hepaticogastrostomy for duodenal obstruction by a cystic adenocarcinoma. a Left bile duct dilation on computed tomography. b Migrated stent within the peritoneal cavity (red arrow shows the migrated stent in the peritoneum). c Puncture of the stent with a 19-gauge needle (red arrow shows the migrated stent within the peritoneum; yellow arrow shows the 19-gauge needle for puncture). d Cystotome recanalization after guidewire placement into the stent.

Video 1 Salvage endoscopic ultrasound-guided puncture and stent placement into a self-expandable metal stent that had migrated into the peritoneum during a hepaticogastrostomy procedure.


Quality:
Zoom Image
Fig. 2 Second stent placement into the migrated stent to make a bridge between the left bile duct and the stomach. a Stent deployment into the migrated stent. b Confirmation of no leakage. c Second stent opening and bile drainage into the stomach. d Fluoroscopic control.

Peritoneal migration of the stent during hepaticogastrostomy is a highly stressful adverse event. Without changing the scope, EUS puncture to place a guidewire and to introduce an SEMS into the migrated stent can save the procedure to achieve the hepaticogastrostomy without leakage.

Endoscopy_UCTN_Code_CPL_1AL_2AD

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high
quality video and all contributions are
freely accessible online.

This section has its own submission
website at
https://mc.manuscriptcentral.com/e-videos



Publication History

Article published online:
19 June 2020

© 2020. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Wang K, Zhu J, Xing L. et al. Assessment of efficacy and safety of EUS-guided biliary drainage: a systematic review. Gastrointest Endosc 2016; 83: 1218-1227
  • 2 Martins FP, Rossini LG, Ferrari AP. Migration of a covered metallic stent following endoscopic ultrasound-guided hepaticogastrostomy: fatal complication. Endoscopy 2010; 42: 126-127
  • 3 Saito T, Hamada T, Kogure H. et al. Digital cholangioscopy-guided retrieval of a migrated hepaticogastrostomy stent through a created hepaticogastrostomy route. Endoscopy 2020; DOI: 10.1055/a-1119-0987.
  • 4 Pham KD-C, Hoem D, Horn A. et al. Salvage of a dislodged hepaticogastrostomy stent in the peritoneum with NOTES. Endoscopy 2017; 49: 919-920
  • 5 De Moura DTH, Mestieri LHM, Cheng S. et al. Natural orifice transluminal endoscopic surgery to salvage a migrated stent during EUS-guided hepaticogastrostomy. Gastrointest Endosc 2016; 83: 656-657