CC BY-NC-ND 4.0 · Endosc Int Open 2020; 08(10): E1302-E1307
DOI: 10.1055/a-1220-6562
Original article

Endoscopic submucosal dissection and tunneling procedures using a novel all-in-one bipolar device

Zaheer Nabi
1   Asian Institute of Gastroenterology – Medical Gastroenterology, Hyderabad, India
,
Radhika Chavan
2   Asian Institute of Gastroenterology – Gastroenterology, Hyderabad, India
,
Mohan Ramchandani
2   Asian Institute of Gastroenterology – Gastroenterology, Hyderabad, India
,
Zacharias Tsiamoulos
3   St. Mark’s Hospital – Gastroenterology, Harrow, UK
,
Jahanqeer Basha
4   PGIMER – Gastroenterology, Chandigarh, India
,
Rajesh Goud
2   Asian Institute of Gastroenterology – Gastroenterology, Hyderabad, India
,
Santosh Darisetty
2   Asian Institute of Gastroenterology – Gastroenterology, Hyderabad, India
5   Asian Institute of Gastroenterology – Anesthesia, Hyderabad, India
,
Nageshwar Reddy
2   Asian Institute of Gastroenterology – Gastroenterology, Hyderabad, India
› Author Affiliations

Abstract

Background and study aims Recent innovations in devices and techniques have revolutionized the field of endoscopic resection procedures. In this study, we evaluated the safety and feasibility of endoscopic submucosal dissection and tunneling procedures with a novel, multipurpose bipolar device.

Patients and methods Data from consecutive patients who underwent per-oral endoscopic myotomy (POEM), submucosal tunneling endoscopic resection (STER), and endoscopic submucosal dissection (ESD) using a novel bipolar device (December 2019 to February 2020) were analyzed retrospectively. Procedure duration, technical success, and adverse events (AEs) were recorded.

Results A total of 10 procedures were performed using the novel bipolar device during the study period. The procedures included POEM (n = 7), STER for esophageal sub-epithelial tumor (n = 1), ESD for rectal polyp (n = 1), and gastric neuroendocrine tumor (n = 1). POEM was successfully completed in all patients. In patients who underwent STER and ESD, en-bloc resection was achieved in all. Mean procedure time for submucosal tunneling procedures (POEM and STER) was 59.12 ± 31.12 minutes. The procedures were completed without the requirement for exchange of accessories in eight cases (80 %). There were no major AEs. Mild and moderate AEs occurred during POEM and included capno-peritoneum (n = 1), retroperitoneal CO2 (n = 1), and empyema (n = 1).

Conclusion ESD and tunneling procedures can be safely performed without the need for exchange of accessories using a novel bipolar device. Randomized comparison with conventional knives isrequired to confirm the utility of this device.



Publication History

Received: 09 April 2020

Accepted: 22 May 2020

Article published online:
22 September 2020

© 2020. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commecial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Nabi Z, Nageshwar Reddy D. et al. Recent Advances in Third-Space Endoscopy. Gastroenterol Hepatol (NY) 2018; 14: 224-232
  • 2 Kumta NA, Kedia P, Lambroza A. et al. Successful peroral endoscopic myotomy with use of a single instrument multipurpose knife. Gastrointest Endosc 2014; 80: 1168
  • 3 Bittinger M, Messmann H. Use of the stag-beetle knife for peroral endoscopic myotomy for achalasia: a novel method for myotomy. Gastrointest Endosc 2015; 82: 401-402
  • 4 Tanaka S, Toyonaga T, Kawara F. et al. Peroral endoscopic myotomy using FlushKnife BT: a single-center series. Endosc Int Open 2017; 5: E663-E669
  • 5 Shimizu T, Fortinsky KJ, Chang KJ. Early experience with use of an endoscopic "hot" scissor-type knife for myotomy during per-oral endoscopic myotomy procedure. VideogastrointestinalE 2019; 4: 182-184
  • 6 Cai MY, Zhou PH, Yao LQ. et al. Peroral endoscopic myotomy for idiopathic achalasia: randomized comparison of water-jet assisted versus conventional dissection technique. Surg Endosc 2014; 28: 1158-1165
  • 7 Nabi Z, Ramchandani M, Chavan R. et al. Outcome of peroral endoscopic myotomy in achalasia cardia: Experience with a new triangular knife. Saudi J Gastroenterol 2018; 24: 18-24
  • 8 Nabi Z, Ramchandani M, Jagtap N. et al. Endoscopic treatment of Zenker's diverticulum using a new triangle tip knife. Ann Gastroenterol 2019; 32: 650-653
  • 9 Nabi Z, Ramchandani M, Chavan R. et al. Endoscopic dissection of an esophageal submucosal tumor using a novel bipolar radiofrequency device. Endoscopy 2020; 52: E257-E258
  • 10 Nabi Z, Ramchandani M, Darisetty S. et al. Peroral endoscopic myotomy in a patient with failed Heller’s myotomy by use of a novel bipolar radiofrequency device. VideogastrointestinalE 2020; DOI: 10.1016/j.vgie.2019.12.009.
  • 11 Cotton PB, Eisen GM, Aabakken L. et al. A lexicon for endoscopic adverse events: report of an ASGE workshop. Gastrointest Endosc 2010; 71: 446-454
  • 12 Nabi Z, Reddy DN, Ramchandani M. Adverse events during and after per-oral endoscopic myotomy: prevention, diagnosis, and management. Gastrointest Endosc 2018; 87: 4-17
  • 13 Ohara Y, Toyonaga T, Hoshi N. et al. Usefulness of a novel slim type FlushKnife-BT over conventional FlushKnife-BT in esophageal endoscopic submucosal dissection. World J Gastroenterol 2017; 23: 1657-1665
  • 14 Tsiamoulos ZP, Sebastian J, Bagla N. et al. A new approach to endoscopic submucosal tunneling dissection: the "Speedboat-RS2" device. Endoscopy 2019; 51: E185-E186