CC BY-NC-ND 4.0 · Endosc Int Open 2021; 09(03): E427-E437
DOI: 10.1055/a-1319-0915
Original article

Experimental study of loop shape using 0.025-inch ERCP guidewires (with videos)

Takeshi Ogura
2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Saori Ueno
2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Atsushi Okuda
2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Nobu Nishioka
2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Tadahiro Yamada
2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Masanori Yamada
2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Kazuya Ueshima
2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Jun Matsuno
2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Yoshitaro Yamamoto
2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Kazuhide Higuchi
2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan
› Author Affiliations

Abstract

Background and study aims Duct penetration by the guidewire sometimes occurs during endoscopic retrograde cholangiography, which might lead to adverse events such as acute pancreatitis. To prevent duct penetration, making a loop shape with the guidewire might provide a useful technique. The aim of this experimental study was thus to evaluate which types of guidewire can most easily form a loop shape.

Methods This experimental study evaluated six guidewires (0.025-inch, angle type): MICHISUJI; VisiGlide 2; Jagwire; Pathcorse; RevoWave-α UltraHard 2; and M-through. Flexibility of the tip, shaft stiffness, and the ability to form a loop were evaluated for each type in an ex vivo model. Deformation behavior was also recorded on video, and factors suitable for making a loop shape in each guidewire were evaluated.

Results Flexibility and stiffness of each guidewire differed significantly. During an experimental study regrading deformation behavior before forming a loop shape, maximum load was lower for MICHISUJI (6.8 g) than for other guidewires (Jagwire [11.3 g], M-through [12.9 g], VisiGlide 2 [12.9 g], Revowave [21 g], and Pathcorse [25.4 g]). Mean time required to achieve a loop shape was as follows: MICHISUJI, 6.2 seconds; M-through, 8.7 seconds; VisiGlide 2, 11.0 seconds; and Revowave, 7.1 seconds.

Conclusion In conclusion, characteristics of flexibility and stiffness among guidewires were significantly different in the ex-vivo study. In the experimental study regrading deformation behavior until achieving a loop shape, maximum load also differed. To evaluate whether guidewires easily form a loop shape, clinical study is needed.



Publication History

Received: 24 June 2020

Accepted: 05 October 2020

Article published online:
19 February 2021

© 2021. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commecial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Tse F, Yuan Y, Moayyedi P. et al. Double-guidewire technique in difficult biliary cannulation for the prevention of post-ERCP pancreatitis: a systematic review and meta-analysis. Endoscopy 2017; 49: 15-26
  • 2 Coté GA, Ansstas M, Pawa R. et al. Difficult biliary cannulation: use of physician-controlled wire-guided cannulation over a pancreatic duct stent to reduce of precut sphincterotomy (with video). Gastrointest Endosc 2010; 71: 275-279
  • 3 Isayama H, Komatsu Y, Tsujino T. et al. A prospective randomized study of “covered” versus “uncovered” diamond stents for the management of distal malignant biliary obstruction. Gut 2004; 53: 729-734
  • 4 Ogura T, Takenaka M, Shiomi H. et al. Single-session multiple stent deployment using moving cell stent without initial stent mesh to treat malignant hilar biliary obstruction (with videos). J Hepatobiliary Pancreat Sci 2020; 27: 84-89
  • 5 Itoi T, Sofuni A, Itokawa F. et al. Current status and issues regarding biliary stenting in unresectable biliary obstruction. Dig Dis Sci 2013; 25: 63-70
  • 6 Ogura T, Yamada M, Ueno S. et al. Hybrid placement technique for hepatic hilar obstruction using a new uncovered self-expandable metal stent. Endosc Int Open 2019; 7: E1288-E1292
  • 7 Teoh AYB, Dhir V, Kida M. et al. Consensus guideline on the optimal management in interventional EUS procedures: results from the Asian EUS group RAND/UCLA expert panel. Gut 2018; 67: 1209-1228
  • 8 Dhir V, Isayama H, Itoi T. et al. Endoscopic ultrasonography-guided biliary and pancreatic duct interventions. Dig Endosc 2017; 29: 472-485
  • 9 Ogura T, Yamada M, Nishioka N. et al. Gastrointestinal: Knuckle guidewire insertion: Safe techniques of guidewire insertion into the pancreatobiliary tract using a novel 0.025-inchu guidewire. J Gastroenterol Hepatol 2020; 35: 707
  • 10 Masci E, Mangiavillano B, Luigiano C. et al. Comparison between loop-tip guidewire assisted and conventional endoscopic cannulation in high risk patients. Endosc Int Open 2015; 3: E464-E470
  • 11 Saki Y, Tsuyuguchi T, Sugiyama H. et al. Prevention of post-endoscopic retrograde cholangiopancreatography pancreatitis by pancreatic duct stenting using a loop-tipped guidewire. World J Clin Cases 2016; 16: 213-218
  • 12 Takashima K, Tsuzuki S, Ooike A. et al. Numerical analysis and experimental observation of guidewire motion in a blood vessel model. Med Eng Phys 2014; 36: 1672-1683
  • 13 Bagbanci S. Holmium: Yttrium aluminum garnet laser and guidewires: is there a durability difference among guidewires against laser energy? An In Vitro Experimental Study. . J Endourol 2017; 31: 528-532
  • 14 Kwiatkowski PS, Malachowski J, Jakubas-Kwiatkowska W. et al. The effects of types of guidewires and pressure applied during stent implantation in the main vessel on the incidence of damage to coronary guidewires during angioplasty of coronary bifurcation lesions-Wide Beast study. J Interv Cardiol 2018; 31: 599-607
  • 15 Kwon CI, Koh DH, Song TJ. et al. Technical reports of ERCP guidewire on the basis of physical properties. Clin Endosc 2020; 53: 65-72
  • 16 Park JS, Jeong S, Lee DH. Effectiveness of a novel highly flexible-tip guidewire on selective biliary cannulation compared to conventional guidewire: randomized controlled study. Dig Endosc 2018; 30: 245-251