CC BY-NC-ND 4.0 · Endosc Int Open 2021; 09(03): E461-E469
DOI: 10.1055/a-1337-2321
Original article

Prevalence of and risk factors for stent migration-induced duodenal perforation

Pauline M.C. Stassen
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands
,
David M. de Jong
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands
,
Jan-Werner Poley
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands
,
Marco J. Bruno
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands
,
Pieter J.F. de Jonge
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands
› Author Affiliations

Abstract

Background and study aims The safety of transpapillary biliary drainage by stent placement through endoscopic retrograde cholangiography (ERC) may be compromised by the occurrence of stent migration-induced perforation of the duodenal wall (SMDP). We aimed to assess the prevalence rate, risk factors and clinical course of SMDP.

Patients and methods This retrospective cohort study included all patients who underwent an ERC with biliary plastic stent placement, between January 2014 and December 2018. Patients with an SMDP were identified from our endoscopy complication registry.

Results 1227 patients underwent an ERC, of whom 629 patients (51 %) with biliary plastic stent placement; in 304 patients (25 %) stents were placed for perihilar strictures. Thirteen patients with SMDP were identified. The prevalence was 2.1 % for patients with biliary plastic stent placement and 4.3 % for patients stented for a perihilar stricture. All SMDPs occurred in patients with a perihilar stricture and with stents ≥ 12 cm (range 12–20 cm). Another potential risk factor was stent insertion into the left liver lobe, which was present in 10 of 13 patients. In 10 of 13 patients, SMDP was clinically suspected. Three of 13 patients were asymptomatic and diagnosed at elective stent retrieval. Eight patients could be endoscopically treated with an over-the-scope clip. Four patients died due to abdominal sepsis despite repeated interventions.

Conclusion SMDP is a rare but potentially life-threatening complication of ERC after transpapillary drainage for perihilar biliary strictures. Stents ≥ 12 cm and stent insertion into the left liver lobe may be associated risk factors.



Publication History

Received: 07 August 2020

Accepted: 19 November 2020

Article published online:
19 February 2021

© 2021. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commecial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany

 
  • References

  • 1 Dumonceau JM, Tringali A, Papanikolaou IS. et al. Endoscopic biliary stenting: indications, choice of stents, and results: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline – Updated October 2017. Endoscopy 2018; 50: 910-930
  • 2 Anderson MA, Appalaneni V. et al. American Society for Gastrointestinal Endoscopy Standards of Practice C. The role of endoscopy in the evaluation and treatment of patients with biliary neoplasia. Gastrointest Endosc 2013; 77: 167-174
  • 3 Moy BT, Birk JW. An update to hepatobiliary stents. J Clin Transl Hepatol 2015; 3: 67-77
  • 4 Coppola R, Masetti R, Riccioni ME. et al. Early retroduodenal perforation following endoscopic internal biliary drainage. Endoscopy 1993; 25: 255-256
  • 5 Humar A, Barron PT, Sekar AS. et al. Pancreatitis and duodenal perforation as complications of an endoscopically placed biliary stent. Gastrointest Endosc 1994; 40: 365-366
  • 6 Marano Jr BJ , Bonanno CA. Metallic biliary endoprosthesis causing duodenal perforation and acute upper gastrointestinal bleeding. Gastrointest Endosc 1994; 40: 257-258
  • 7 Bui BT, Oliva VL, Ghattas G. et al. Percutaneous removal of a biliary stent after acute spontaneous duodenal perforation. Cardiovasc Intervent Radiol 1995; 18: 200-202
  • 8 Roses LL, Ramirez AG, Seco AL. et al. Clip closure of a duodenal perforation secondary to a biliary stent. Gastrointest Endosc 2000; 51: 487-489
  • 9 Novacek G, Hormann M, Puig S. et al. Duodenal perforation secondary to placement of a biliary endoprosthesis diagnosed by multislice computed tomography. Endoscopy 2002; 34: 351
  • 10 Miller G, Yim D, Macari M. et al. Retroperitoneal perforation of the duodenum from biliary stent erosion. Curr Surg 2005; 62: 512-515
  • 11 Paikos D, Gatopoulou A, Moschos J. et al. Migrated biliary stent predisposing to fatal ERCP-related perforation of the duodenum. J Gastrointestin Liver Dis 2006; 15: 387-388
  • 12 Fatima J, Baron TH, Topazian MD. et al. Pancreaticobiliary and duodenal perforations after periampullary endoscopic procedures: diagnosis and management. Arch Surg 2007; 142: 448-454 ; discussion 454-445
  • 13 Bharathi RS, Rao PP, Ghosh K. Intra-peritoneal duodenal perforation caused by delayed migration of endobiliary stent: a case report. Int J Surg 2008; 6: 478-480
  • 14 Hsu YC, Wu YM, Wang HP. Education of imaging. Hepatobiliary and pancreatic: biliary stent causing imminent duodenal perforation. J Gastroenterol Hepatol 2008; 23: 817
  • 15 Lee TH, Park DH, Park JY. et al. Aortoduodenal fistula and aortic aneurysm secondary to biliary stent-induced retroperitoneal perforation. World Journal of Gastroenterology 2008; 14: 3095-3097
  • 16 Lo CH, Chung S, Bohmer RD. A devastating complication: duodenal perforation due to biliary stent migration. Surg Laparosc Endosc Percutan Tech 2008; 18: 608-610
  • 17 Yaprak M, Mesci A, Colak T. et al. Biliary stent migration with duodenal perforation. Eurasian J Med 2008; 40: 154-156
  • 18 Zeb F, Kevans D, Muir K. et al. Duodenal impaction/perforation of a biliary stent--a rare complication in the management of choledocholithiasis. J Gastrointestin Liver Dis 2009; 18: 391-392
  • 19 Lin H, Li ZS, Zhan XB. Asymptomatic duodenal perforation from obstructed and migrated biliary stent. Endoscopy 2011; 43 (Suppl. 02) E40-41
  • 20 Siddiqui AA, Mehendiratta V, Loren D. et al. Fully covered self-expandable metal stents are effective and safe to treat distal malignant biliary strictures, irrespective of surgical resectability status. J Clin Gastroenterol 2011; 45: 824-827
  • 21 Prachayakul V, Aswakul P, Kachintorn U. Duodenal perforation due to plastic stent migration successfully treated by endoscopy. Gastrointest Endosc 2012; 75: 1265-1266
  • 22 Smart P, Keenan D, Campbell W. et al. Duodenal perforation secondary to migration of endobiliary prosthesis. BMJ Case Rep 2012; DOI: 10.1136/bcr-2012-006711.
  • 23 Issa H, Nahawi M, Bseiso B. et al. Migration of a biliary stent causing duodenal perforation and biliary peritonitis. World J Gastrointest Endosc 2013; 5: 523-526
  • 24 El Zein MH, Kumbhari V, Tieu A. et al. Duodenal perforation as a consequence of biliary stent migration can occur regardless of stent type or duration. Endoscopy 2014; 46 (Suppl. 01) E281-282
  • 25 Kusters PJ, Keulen ET, Peters FP. Duodenal perforation following bile duct endoprosthesis placement. Endoscopy 2014; 46 (Suppl. 01) E646-647
  • 26 Kriss M, Yen R, Fukami N. et al. Duodenal perforation secondary to migrated biliary stent in a liver transplant patient: successful endoscopic closure with an over-the-scope clip. Gastrointest Endosc 2015; 81: 1258-1259
  • 27 Barakat MT, Kothari S, Banerjee S. Cut and Paste: endoscopic management of a perforating biliary stent utilizing scissors and clips. Dig Dis Sci 2018; 63: 2202-2205
  • 28 Ferm S, Fisher C, Hassam A. et al. Primary endoscopic closure of duodenal perforation secondary to biliary stent migration: a case report and review of the literature. J Investig Med High Impact Case Rep 2018; 6 DOI: 10.1177/2324709618792031.
  • 29 Ekmektzoglou K, Nikou E, Apostolopoulos P. et al. Size does matter: when a large plastic biliary stent ends up in the root of the mesentery. Clinical Journal of Gastroenterology 2019; 12: 102-105
  • 30 Kim SH, Moon JH, Lee YN. et al. Endoscopic management of duodenal perforations caused by migrated biliary plastic stents. Endosc Int Open 2019; 7: E792-E795
  • 31 Saranga Bharathi R, Rao P, Ghosh K. Iatrogenic duodenal perforations caused by endoscopic biliary stenting and stent migration: an update. Endoscopy 2006; 38: 1271-1274
  • 32 Dumonceau JM, Kapral C, Aabakken L. et al. ERCP-related adverse events: European Society of Gastrointestinal Endoscopy (ESGE) Guideline. Endoscopy 2020; 52: 127-149
  • 33 Grunhagen DJ, Dunne DF, Sturgess RP. et al. Metal stents: a bridge to surgery in hilar cholangiocarcinoma. HPB (Oxford) 2013; 15: 372-378
  • 34 Dumonceau JM, Tringali A, Papanikolaou IS. et al. Endoscopic biliary stenting: indications, choice of stents, and results: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline – Updated October 2017. Endoscopy 2018; 50: 910-930
  • 35 Naitoh I, Inoue T, Hayashi K. Which is better for unresectable malignant hilar biliary obstruction: Side-by-side versus stent-in-stent?. Int J Gastrointest Interv 2018; 7: 78-84