Endoscopic ultrasound-guided pancreatic pseudocyst drainage using a novel double-lumen dilator
Authors

Endoscopic ultrasound-guided pancreatic pseudocyst drainage (EUS-PPD) is a well-established technique [1] [2] [3]. The procedure can be performed using a lumen-apposing metal stent (LAMS), allowing effective drainage because of the large diameter of the stent compared with plastic stents. However, a recent meta-analysis comparing EUS-PPD using plastic stents and LAMS reported similar technical and clinical success rates [4]. Additionally, plastic stent deployment still plays an important role from the perspective of cost-effectiveness in cases of pancreatic pseudocysts with fluid contents. However, the procedure requires deployment of two plastic stents, two guidewire insertions, and tract dilation after deployment of the first plastic stent. This leads to prolonged procedure time and higher costs. To overcome these issues, a novel dilation device (Meissa; Japan Lifeline, Tokyo, Japan) has been developed ([Fig. 1]) [5]. The tip of this device is 2.3 Fr, and its maximum diameter is 7.4 Fr. In addition, a side hole is provided 2 cm from the tip. This enables contrast medium injection, aspiration of infected cyst fluid, and additional 0.025-inch guidewire insertion to be performed. Herein, we describe the technical procedure for EUS-PPD using this device.


A 55-year-old man was admitted to our hospital for the treatment of a pancreatic pseudocyst. Since EUS imaging showed that the pancreatic pseudocyst mainly contained fluid, EUS-PPD using a plastic stent was attempted. The pseudocyst was punctured using a 19G needle, and a 0.025-inch guidewire was inserted into the cyst ([Fig. 2]). Next, a double-lumen dilator was smoothly inserted into the cyst. Then, an additional 0.025-inch guidewire was inserted into the cyst via the double-lumen dilator ([Fig. 3]), and a 7-Fr double-pigtail plastic stent was subsequently deployed ([Fig. 4]). Finally, insertion of an additional 7-Fr double-pigtail plastic stent was attempted. Since insertion of the double-lumen dilator had resulted in adequate tract dilation, this procedure was successfully performed without additional tract dilation or adverse events ([Fig. 5], [Video 1]).








In conclusion, the novel double-lumen dilator might serve a dual purpose during EUS-PPD, namely, allowing double guidewire deployment and tract dilation.
Endoscopy_UCTN_Code_TTT_1AS_2AJ
E-Videos is an open access online section of the journal Endoscopy, reporting on interesting cases and new techniques in gastroenterological endoscopy.
All papers include a high-quality video and are published with a Creative Commons
CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission
process. We grant 100% waivers to articles whose corresponding authors are based in
Group A countries and 50% waivers to those who are based in Group B countries as classified
by Research4Life (see: https://www.research4life.org/access/eligibility/).
This section has its own submission website at https://mc.manuscriptcentral.com/e-videos.
Publication History
Article published online:
22 May 2025
© 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/).
Georg Thieme Verlag KG
Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
-
References
- 1 Haney CM, Kowalewski KF, Schmidt MW. et al. Endoscopic versus surgical treatment for infected necrotizing pancreatitis: a systematic review and meta-analysis of randomized controlled trials. Surg Endosc 2020; 34: 2429-2444
- 2 Aburajab M, Smith Z, Khan A. et al. Safety and efficacy of lumen-apposing metal stents with and without simultaneous double-pigtail plastic stents for draining pancreatic pseudocyst. Gastrointest Endosc 2018; 87: 1248-1255
- 3 Yang D, Perbtani YB, Mramba LK. et al. Safety and rate of delayed adverse events with lumen-apposing metal stents (LAMS) for pancreatic fluid collections: a multicenter study. Endosc Int Open 2018; 6: E1267-E1275
- 4 Guzmán-Calderón E, Chacaltana A, Díaz R. et al. Head-to-head comparison between endoscopic ultrasound guided lumen apposing metal stent and plastic stents for the treatment of pancreatic fluid collections: A systematic review and meta-analysis. J Hepatobiliary Pancreat Sci 2022; 29: 198-211
- 5 Ogura T. Opening a new window of interventional endoscopic ultrasound using a 22-G needle with a novel dedicated dilation device. Endoscopy 2024; 56: E1104-E1105