Salvaging hilar access using an uneven double-lumen cannula in endoscopic ultrasound-guided hepaticogastrostomy
Authors

A common challenge in endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is misdirection of the guidewire into the peripheral bile duct instead of the desired hilar direction. This situation, which often occurs with acute puncture angles, complicates the procedure. The uneven double-lumen cannula (UDC) (Uneven Double Lumen Cannula; Piolax Medical, Kanagawa, Japan) is a valuable tool in these cases, enabling successful hilar guidewire placement as a rescue technique known as the “uneven method” [1]. UDCs have two lumen orifices a short (5-mm) or long (30-mm) distance apart. The long-type UDC is particularly useful for hilar guidewire access because its distal tip remains securely in the bile duct, allowing precise proximal orifice repositioning.
A 68-year-old woman who had undergone pancreaticoduodenectomy presented with liver dysfunction. Computed tomography revealed dilated bile ducts ([Fig. 1]) consistent with cholangitis. An initial attempt at biliary stenting via double-balloon endoscopic retrograde cholangiopancreatography was unsuccessful because of jejunal obstruction caused by peritoneal metastasis. Therefore, EUS-HGS was performed for biliary stenting ([Video 1]). Under EUS guidance (GF-UCT260; Olympus Medical, Tokyo, Japan), the B3 bile duct was punctured using a 22-gauge fine-needle aspiration needle (EZ Shot 3 Plus; Olympus Medical). However, attempts to advance a 0.018-inch guidewire (J-Wire Premier 18 NM; J-MIT, Kyoto, Japan) toward the hilum were unsuccessful, and the guidewire was consistently tracked into a peripheral branch ([Fig. 2]). After peripheral positioning of the guidewire, a long-type UDC was inserted ([Fig. 3]). A 0.025-inch guidewire (Visiglide2; Olympus Medical) was then successfully navigated into the hilum through the proximal lumen orifice of the UDC and across the hepaticojejunostomy anastomosis. The initial 0.018-inch guidewire was then re-inserted to establish a double-guidewire platform [2] ([Fig. 4]). An uncovered self-expandable metallic stent (Yabusame Neo; Kaneka Medix, Osaka, Japan) was placed as antegrade stenting, and a 7-Fr plastic stent (Type IT; Gadelius Medical, Tokyo, Japan) was placed across the EUS-guided created route ([Fig. 5]).










Endoscopy_UCTN_Code_CPL_1AL_2AD
E-Videos is an open access online section of the journal Endoscopy, reporting on interesting cases and new techniques in gastroenterological endoscopy.
All papers include a high-quality video and are published with a Creative Commons
CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission
process. We grant 100% waivers to articles whose corresponding authors are based in
Group A countries and 50% waivers to those who are based in Group B countries as classified
by Research4Life (see: https://www.research4life.org/access/eligibility/).
This section has its own submission website at https://mc.manuscriptcentral.com/e-videos.
Publikationsverlauf
Artikel online veröffentlicht:
26. September 2025
© 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/).
Georg Thieme Verlag KG
Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
-
References
- 1 Takenaka M, Kudo M. Usefulness of the double-guidewire technique for endoscopic procedures in the field of biliary and pancreatic diseases. Clin Endosc 2022; 55: 605-614
- 2 Fujii Y, Kato H, Himei H. et al. Double guidewire technique stabilization procedure for endoscopic ultrasound-guided hepaticogastrostomy involving modifying the guidewire angle at the insertion site. Surg Endosc 2022; 36: 8981-8991