Int J Sports Med 2012; 33(12): 1010-1015
DOI: 10.1055/s-0032-1316362
Training & Testing
© Georg Thieme Verlag KG Stuttgart · New York

Different V˙O2max Time-Averaging Intervals in Swimming

R. J. Fernandes
1   Centre of Research, Education, Innovation and Intervention in Sport, Faculty of Sport, University of Porto, Portugal
2   Porto Biomechanics Laboratory, University of Porto, Portugal
,
K. de Jesus
1   Centre of Research, Education, Innovation and Intervention in Sport, Faculty of Sport, University of Porto, Portugal
,
C. Baldari
3   Department of Health Sciences, University of Rome “Foro Italico”, Rome, Italy
,
K. de Jesus
1   Centre of Research, Education, Innovation and Intervention in Sport, Faculty of Sport, University of Porto, Portugal
,
A. C. Sousa
1   Centre of Research, Education, Innovation and Intervention in Sport, Faculty of Sport, University of Porto, Portugal
,
J. P. Vilas-Boas
1   Centre of Research, Education, Innovation and Intervention in Sport, Faculty of Sport, University of Porto, Portugal
2   Porto Biomechanics Laboratory, University of Porto, Portugal
,
L. Guidetti
3   Department of Health Sciences, University of Rome “Foro Italico”, Rome, Italy
› Author Affiliations
Further Information

Publication History



accepted after revision 17 May 2012

Publication Date:
12 July 2012 (online)

Abstract

We aimed to determine the effect of sampling interval strategy on V˙O2max assessment to establish a standard time averaging method that allows a better identification of the V˙O2 plateau incidence in swimming. To this end, 3 incremental protocols utilizing different step lengths for each sampling interval were used to compare V˙O2max measurements. 11 trained male swimmers performed 3 repetitions of a front crawl intermittent incremental protocol until exhaustion (increments of 0.05 m.s − 1, with 30 s and 24–48 h intervals between steps and tests, respectively) with 200, 300 and 400-m step lengths. V˙O2 was directly measured, and 6 sampling intervals were compared: bxb and averages of 5, 10, 15, 20 and 30 s. Shorter sampling intervals (≤15 s) allowed the highest incidence of the V˙O2 plateau, independent of the step lengths used; the 200 and 300-m step protocols accounted for higher percentage of V˙O2 plateau incidence, and higher V˙O2max values, compared to the 400-m step protocol. As an optimal sampling interval should be used for the validation of the research findings, and considering that swimmers and coaches prefer less time-consuming protocols, the use of the 10 s time-average interval (once bxb and 5 s samplings present high variability) in a 200-m step incremental protocol for V˙O2max assessment in swimming is suggested.

 
  • References

  • 1 Astorino TA, Robergs RA, Ghiasvand F, Marks D, Burns S. Incidence of the oxygen plateau at V˙O2max during exercise testing to volitional fatigue. J Exerc Physiol 2000; 3: 1-12
  • 2 Astorino TA. Alterations in V˙O2max and the V˙O2 plateau with manipulation of sampling intervals. Clin Physiol Funct Imaging 2009; 29: 60-67
  • 3 Astrand PQ, Engström L, Eriksson B, Karlberg P, Nylander I, Saltin B, Thorén C. Girl swimmers. Act Paediatr Scand 1963; 147 (Suppl) 1-39
  • 4 Baldari C, Fernandes RJ, Meucci M, Ribeiro J, Vilas-Boas JP, Guidetti L. Is the New AquaTrainer®Snorkel Proper for V˙O2 Assessment in Swimming?. Int J Sports Med 2012; DOI: 10.1055/s-0032-1321804.
  • 5 Barbosa T, Silva AJ, Reis AM, Costa M, Garrido N, Policarpo F, Reis VM. Kinematical changes in swimming front crawl and breaststroke with the AquaTrainer® snorkel. Eur J Appl Physiol 2010; 109: 1155-1162
  • 6 Demarie S, Sardella F, Billat V, Magini W, Faina M. The VO2 slow component in swimming. Eur J Appl Physiol 2001; 84: 95-99
  • 7 Di Prampero PE. The energy cost of human locomotion on land and in water. Int J Sports Med 1986; 7: 55-72
  • 8 Duffield R, Dawson B, Pinnington HC, Wong P. Accuracy and reliability of a Cosmed K4b2 portable gas analysis system. J Sci Med Sport 2004; 7: 11-22
  • 9 Dwyer D. A standard method for the determination of maximal aerobic power from breath-by-breath VO2 data obtained during a continuous ramp test on a bicycle ergometer. J Exerc Physiol 2004; 7: 1-9
  • 10 Fernandes RJ, Billat VL, Cruz AC, Colaco PJ, Cardoso CS, Vilas-Boas JP. Does net energy cost of swimming affect time to exhaustion at the individual’s maximal oxygen consumption velocity?. J Sports Med Phys Fitness 2006; 46: 373-380
  • 11 Fernandes RJ, Keskinen K, Colaço P, Querido AJ, Machado LJ, Morais PA, Novais DQ, Marinho DA, Vilas-Boas JP. Time limit at VO2max velocity in elite crawl swimmers. Int J Sport Med 2008; 29: 145-150
  • 12 Fernandes RJ, Sousa M, Machado L, Vilas-Boas JP. Step length and individual anaerobic threshold assessment in swimming. Int J Sport Med 2011; 32: 1-7
  • 13 Guidetti L, Emerenziani GP, Galotta MC, da Silva SG, Baldari C. Energy cost and energy sources of a ballet dance exercise in female adolescents with different technical ability. Eur J Appl Physiol 2008; 10: 315-321
  • 14 Harriss DJ, Atkinson G. Update – ethical standards in sport and exercise science research. Int J Sports Med 2011; 32: 819-821
  • 15 Hill DW, Stephens LP, Blumoff-Ross SA, Poole DC, Smith JC. Effect of sampling strategy on measures of VO2 peak obtained using commercial breath-by-breath systems. Eur J Appl Physiol 2003; 89: 564-569
  • 16 Holmér I. Physiology of swimming man. Acta Phys Scand 1974; 407 (Suppl) 1-55
  • 17 Howley ET, Basseet T, Welch HG. Criteria for maximal oxygen uptake: review and commentary. Med Sci Sport Exerc 1995; 27: 1292-1301
  • 18 Karpovich PV, Milman N. Energy expenditure in swimming. Am J Physiol 1944; 142: 140-144
  • 19 Komar J, Leprêtre PM, Alberty M, Vantorre J, Fernandes RJ, Hellard P, Chollet D, Seifert L. Effect of increasing energy cost on arm coordination in elite sprint swimmers. Hum Movement Sci 2011; [Epub ahead of print]
  • 20 Kuipers H, Rietjens G, Verstappen F, Schoenmakers H, Hofman G. Effects of stage duration in incremental running tests on physiological variables. Int J Sports Med 2003; 24: 486-491
  • 21 Laffite LP, Vilas-Boas JP, Demarle A, Silva J, Fernandes R, Billat VL. Changes in physiological and stroke parameters during a maximal 400-m free swimming test in elite swimmers. Can J Appl Physiol 2004; 29 (Suppl) 17-31
  • 22 Libicz S, Roels B, Millet GP. VO2 responses to intermittent swimming sets at velocity associated with VO2max. Can J Appl Physiol 2005; 30: 543-553
  • 23 Liljestrand G, Stenstrom N. Studien uber die Physiologie des Schwimmens. Scand Arch Physiol 1920; 39: 1-63
  • 24 Matthews JI, Bush BA, Morales FM. Microprocessor exercise physiology systems vs. a nonautomated system: a comparison of data output. Chest 1987; 92: 696-703
  • 25 Midgley AW, McNaughton LR, Carroll S. Effect of the V˙O2 time-averaging interval on the reproducibility of V˙O2max in healthy athletic people. Clin Physiol Funct Imaging 2007; 27: 122-125
  • 26 Myers J, Walsh D, Sullivan M, Froelicher V. Effect of sampling on variability and plateau in oxygen uptake. J Appl Physiol 1990; 68: 404-410
  • 27 Özyener F, Rossiter HB, Ward SA, Whipp BJ. Influence of exercise intensity on the on-and off-transient kinetics of pulmonary oxygen uptake. J Physiol 2001; 533: 891-902
  • 28 Pyne D, Maw G, Goldsmith W. Protocols for the physiological assessment of swimmers. In: Gore CJ. (ed.). Physiological tests for elite athletes. Australia: Australian Sports Commission; 2000: 372-382
  • 29 Reis JF, Alves FB, Bruno PM, Vleck V, Millet GP. Effects of aerobic fitness on oxygen uptake kinetics in heavy exercise intensity swimming. Eur J Appl Physiol 2012; 112: 1689-1697
  • 30 Reis VM, Marinho DA, Policarpo FB, Carneiro AL, Baldari C, Silva AJ. Examining the accumulated oxygen deficit method in front crawl swimming. Int J Sport Med 2010; 31: 421-427
  • 31 Reis VM, Marinho DA, Barbosa FP, Reis AM, Guidetti L, Silva AJ. Examining the accumulated oxygen deficit method in breastroke swimming. Eur J Appl Physiol 2010; 109: 1129-1135
  • 32 Rinehardt K, Kraemer R, Gormely S, Colan S. Comparison of maximal oxygen uptakes from the tethered, the 183 and 457 meter unimpeded supramaximal freestyle swims. Int J Sport Med 1991; 12: 6-9
  • 33 Roels B, Schimitt L, Libicz S, Bentley D, Richalet JP, Millet G. Specificity of VO2máx and the ventilatory threshold in free swimming and cycle ergometry: comparison between triathletes and swimmers. Br J Sports Med 2005; 3: 965-968
  • 34 Sousa A, Figueiredo P, Oliveira N, Oliveira J, Keskinen KL, Vilas-Boas JP, Fernandes RJ. Comparison between swimming V˙O2peak and V˙O2max at different time intervals. Open Sports Sci J 2010; 3: 22-24
  • 35 Sousa AC, Figueiredo P, Oliveira NL, Oliveira J, Silva AJ, Keskinen KL, Rodríguez FA, Machado LJ, Vila-Boas JP, Fernandes RJ. V˙O2 kinetics in 200-m race-pace front crawl swimming. Int J Sport Med 2011; 32: 1-6
  • 36 Toussaint HM, Meulemans A, de Groot G, Hollander AP, Schreus AW, Vervoorn K. Respiratory valve for oxygen uptake measurements during swimming. Eur J Physiol 1987; 56: 363-366
  • 37 Troup J, Daniels J. Swimming economy, an introductory review. J Swimming Res 1986; 2: 5-9
  • 38 Vilas-Boas JP, Santos P. Comparison of swimming economy in three breaststroke techniques. In: Miyashita M, Mutoh Y, Richardson AB. (eds.). Medicine and Science in Aquatic Sports. Med Sport Sci. 1994. 39. 48-54 Basel: Karger;