Transrectal endoscopic ultrasound-guided drainage of pelvic abscess with placement of a fully covered self-expandable metal stent

C. Luigiano
1   Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna Bellaria-Maggiore Hospital, Bologna, Italy
,
T. Togliani
2   Unit of Digestive Endoscopy, Carlo Poma Hospital, Mantova, Italy
,
V. Cennamo
1   Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna Bellaria-Maggiore Hospital, Bologna, Italy
,
A. Maimone
1   Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna Bellaria-Maggiore Hospital, Bologna, Italy
,
A. M. Polifemo
1   Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna Bellaria-Maggiore Hospital, Bologna, Italy
,
S. Pilati
2   Unit of Digestive Endoscopy, Carlo Poma Hospital, Mantova, Italy
,
C. Fabbri
1   Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna Bellaria-Maggiore Hospital, Bologna, Italy
› Author Affiliations
Further Information

Publication History

Publication Date:
05 September 2013 (online)

Pelvic abscess developed in an 88-year-old woman (Case 1) following a Hartmann’s procedure for a perforated diverticulum and in a 78-year-old woman (Case 2) after diverticulitis ([Fig. 1]). Conservative management was unsuccessful in the first patient due to advanced age and in the second patient due to severe co-morbidities.

Zoom Image
Fig. 1 Computed tomography showing a pelvic abscess. a Case 1. b Case 2.
Zoom Image

Both patients underwent transrectal endoscopic ultrasound (EUS)-guided drainage of the pelvic abscess using the same technique, with placement of a transmural fully covered self-expandable metal stent (SEMS) ([Video 1]). Briefly, a 19-gauge needle was introduced into the collection using a linear echoendoscope. A 0.035-inch wire was then positioned in the cavity and a pre-cut needle-knife was used to create a fistula. A 10 × 40 mm fully covered SEMS (WallFlex; Microvasive Endoscopy, Boston Scientific Corp., Natick, Massachusetts, USA) was then placed over the guide wire.


Quality:
Transrectal endoscopic ultrasound-guided drainage of pelvic abscess with placement of a fully covered self-expandable metal stent.

After the procedure, the patients improved substantially and were discharged home after 5 and 6 days, respectively.

In both patients, computed tomography (CT) of the pelvis 2 weeks later showed resolution of the abscess ([Fig. 2]). The fully covered SEMSs were then removed by rectoscopy a week later.

Zoom Image
Fig. 2 Computed tomography 2 weeks after drainage, showing resolution of the abscess with transrectal stents visible within the abscess cavity and rectum. a Case 1. b Case 2.
Zoom Image

A follow-up CT 1 month later revealed complete resolution of the abscess in both patients without recurrence ([Fig. 3]).

Zoom Image
Fig. 3 Computed tomography 1 month after stent removal showing resolution without recurrence of the pelvic abscess. a Case 1. b Case 2.
Zoom Image

Recently, EUS-guided drainage has been proposed as a minimally invasive alternative for the drainage of pelvic abscesses [1] [2] [3]. Taking into account the available published data, a drainage catheter and one or two plastic stents for each lesion seem to be the best endoscopic approach [1] [2] [3]. Fully covered SEMSs have also recently been adopted for the drainage of infected pancreatic fluid collections with good results [4].

To the best of our knowledge, these are the first two cases of a fully covered SEMS used for transrectal EUS-guided drainage of pelvic abscesses. We think that the use of these stents can give good results for the drainage of pelvic abscesses.

Endoscopy_UCTN_Code_TTT_1AS_2AZ

 
  • References

  • 1 Giovannini M, Bories E, Moutardier V et al. Drainage of deep pelvic abscesses using therapeutic echo endoscopy. Endoscopy 2003; 35: 511-514
  • 2 Trevino JM, Drelichman ER, Varadarajulu S. Modified technique for EUS-guided drainage of pelvic abscess (with video). Gastrointest Endosc 2008; 68: 1215-1219
  • 3 Varadarajulu S, Drelichman ER. Effectiveness of EUS in drainage of pelvic abscesses in 25 consecutive patients (with video). Gastrointest Endosc 2009; 70: 1121-1127
  • 4 Fabbri C, Luigiano C, Cennamo V et al. Endoscopic ultrasound-guided transmural drainage of infected pancreatic fluid collections with placement of covered self-expanding metal stents: a case series. Endoscopy 2012; 44: 429-433