A target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection

Autoren

  • Atsushi Imagawa

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Hidenori Hata

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Morihito Nakatsu

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Akihiro Matsumi

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Eijiro Ueta

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Kozue Suto

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Hiroyuki Terasawa

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Hiroyuki Sakae

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Keiko Takeuchi

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Manabu Fujihara

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Hitomi Endo

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Hisae Yasuhara

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Shinichi Ishihara

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Hiromitsu Kanzaki

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Hideki Jinno

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Hidenori Kamada

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Eisuke Kaji

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Akio Moriya

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
  • Masaharu Ando

    Department of Gastroenterology, Mitoyo General Hospital, Kagawa, Japan
Weitere Informationen

Publikationsverlauf

submitted 20. Februar 2014

accepted after revision 11. Juni 2014

Publikationsdatum:
17. November 2014 (online)

Background and study aims: Propofol administration via a target-controlled infusion system with bispectral index monitoring (BIS/TCI system) is expected to prevent complications from sedation during complex and long endoscopic procedures. We evaluated the feasibility of setting the BIS/TCI system for non-anesthesiologist administration of propofol (NAAP) during endoscopic submucosal dissection (ESD).

Patients and methods: From May 2009 to February 2013, 250 patients with esophagogastric neoplasms were treated with ESD using the BIS/TCI system with NAAP. In the TCI system, the initial target blood concentration of propofol was set at 1.2 μg/mL. The titration speed of propofol was adjusted according to the BIS score and the movement of the patient. The BIS target level ranged from moderate to deep sedation, at which a stable BIS score between 60 and 80 was obtained.

Results: In 80.4 % of patients, it was possible to maintain stable sedation with a blood concentration of propofol of less than 1.6 µg/mL using TCI throughout the ESD procedure. The default setting for ideal blood concentration of propofol was 1.2 μg/mL, because the medians of the lower and upper bounds of blood concentration were 1.2 μg/mL (range 0.6 – 1.8 μg/mL) and 1.4 μg/mL (range 1.0 – 3.8 μg/mL), respectively. Although hypotension occurred in 27 patients (10.8 %), oxygen desaturation occurred in only nine patients (3.6 %), and severe desaturation in only two patients (0.8 %).

Conclusions: Using our settings, it is possible for a non-anesthesiologist to maintain stable sedation during a lengthy endoscopic procedure through propofol sedation with a BIS/TCI system.