Endoscopy 2015; 47(07): 654-657
DOI: 10.1055/s-0034-1391483
Case series
© Georg Thieme Verlag KG Stuttgart · New York

Cone-beam computed tomography – adding a new dimension to ERCP

Jochen Weigt
1   Department of Gastroenterology, Hepatology and Infectious Diseases, Otto-von-Guericke University of Magdeburg, Germany
,
Maciej Pech
2   Department of Radiology and Nuclear Medicine, 2nd Radiology Department, University of Gdansk, Poland
,
Arne Kandulski
1   Department of Gastroenterology, Hepatology and Infectious Diseases, Otto-von-Guericke University of Magdeburg, Germany
,
Peter Malfertheiner
1   Department of Gastroenterology, Hepatology and Infectious Diseases, Otto-von-Guericke University of Magdeburg, Germany
› Author Affiliations
Further Information

Publication History

submitted 11 November 2014

accepted after revision 31 December 2014

Publication Date:
12 February 2015 (online)

Six patients with biliary duct pathologies were investigated with three-dimensional endoscopic retrograde cholangiopancreatography (3D-ERCP). The technique of 3D-ERCP consists of c-arm rotation using a flat detector c-arm to acquire a complete set of images for 3 D visualization of the biliary system. Our case series demonstrates a high level of accuracy with regard to the diagnosis of stenosis and biliary leakage. In two patients the diagnosis obtained from conventional ERCP changed significantly after 3D-ERCP. From these early observations we conclude that 3D-ERCP enhances the diagnostic performance of ERCP in a subset of patients with biliary tract disease.

 
  • References

  • 1 Hintze RE, Abou-Rebyeh H, Adler A et al. Magnetic resonance cholangiopancreatography-guided unilateral endoscopic stent placement for Klatskin tumors. Gastrointest Endosc 2001; 53: 40-46
  • 2 Kapoor BS, Esparaz A, Levitin A et al. Nonvascular and portal vein applications of cone-beam computed tomography: current status. Tech Vasc Interv Radiol 2013; 16: 150-160
  • 3 Nanashima A, Abo T, Sakamoto I et al. Three-dimensional cholangiography applying C-arm computed tomography in bile duct carcinoma: a new radiological technique. Hepatogastroenterology 2009; 56: 615-618
  • 4 Shimazu M, Wakabayashi G, Tanabe M et al. [Three-dimensional cholangiography and angiography for hilar cholangiocarcinoma]. Nihon Geka Gakkai Zasshi 2000; 101: 393-398
  • 5 Kruit AS, Vleggaar FP, van Erpecum KJ et al. No reduction of radiation dose following the introduction of dose-area product measurement in endoscopic retrograde cholangiopancreatography. Eur J Gastroenterol Hepatol 20.05.2014; DOI: 10.1097/MEG.0000000000000128.