Utility of a stent pusher catheter as a “mini-overtube” in the endoscopic management of post-liver transplant biliary strictures
Publication History
Publication Date:
15 December 2015 (online)
Biliary strictures and biliary leaks are the most common forms of post-transplant biliary complication [1] [2] [3]. These are thought to be due to multiple factors including ischemia, ischemia – reperfusion injuries, cytomegalovirus infection, and surgical techniques [2]. Endoscopic retrograde cholangiopancreatography (ERCP), percutaneous transhepatic cholangiography, and surgery are the primary approaches used in addressing strictures, with ERCP being the gold standard as a diagnostic and therapeutic tool with the use of balloon dilations and placement of multiple parallel plastic stents [1] [2] [3]. However, some strictures have proven to be technically challenging or untreatable, mandating the use of percutaneous transhepatic cholangiographic drainage or even surgical hepaticojejunostomy. Herein we report a new method to deliver two wires above an impassable and severe anastomotic stricture by utilizing the pusher catheter as a “mini-overtube.”
A 55-year-old man had undergone orthotopic liver transplantation (OLT) because of hepatitis C virus-related cirrhosis and hepatocellular carcinoma. After the OLT he had elevated results in liver function tests but biopsy had shown a viable liver transplant. Therefore the patient had undergone ERCP, which had shown an anastomotic biliary stricture. This had been managed by sphincterotomy and placement of a single 10-Fr 12-cm plastic stent because of the severity of the stricture.
At follow-up ERCP, the previous stent was removed using a snare. Biliary sphincterotomy and balloon dilation of the stenosis was performed (6-mm Titan balloon; Cook Medical, Winston Salem, North Carolina, USA) with removal of debris and sludge and extraction of the balloon without complications. However, on further evaluation only a single 0.035-inch guidewire (Metro; Cook Medical) could be advanced through the anastomosis ([Fig. 1]). Several techniques and accessories were used without success in the attempt to pass a second wire: a tapered tip catheter, various sphincterotomes, balloons, and straight and J-tipped wires.
Because the path was so narrow and tortuous, an alternative approach was pursued as follows. A stent delivery device (Cook Medical), namely the inner guiding catheter and pusher without the stent, was passed over the existing guidewire that had crossed the stricture proximally ([Fig. 2 a], [Video 1]). Once the tip of the pusher was above the stricture ([Fig. 2 b]), the inner guiding catheter was removed, leaving the pusher in situ ([Video 1]). The pusher could thus be utilized as a “mini-overtube” allowing the advancement of a second wire inside across the severe anastomotic stricture, so that now two wires could be delivered above the stenosis, one each into the right and left hepatic ducts ([Fig. 3 b], [Video 1]). The pusher tube was then withdrawn, thus allowing the successful insertion of two 10-Fr 12-cm plastic stents (Cotton-Huibregtse; Cook Medical), one along each wire with both stents crossing the stricture ([Fig. 3], [Video 1]).
Quality:
On subsequent ERCP, dilation of the stenosis was more easily obtained (8-mm balloon, Titan; Cook Medical), and again successful insertion of two plastic stents, one along each wire with both stents crossing the stricture (10-Fr Solus plastic double-pigtail 4-cm; 12-cm Cotton-Huibregste Amsterdam plastic stent) ([Fig. 4], [Video 1]).
In summary, we have presented a novel method that allows passage of two (or more) wires above a tight biliary stricture, thus permitting the use of more than one stent to treat a complex stricture. The concept of “mini-overtube” in ERCP is useful as it expands the therapeutic possibilities in complex cases such as the one presented.
Endoscopy_UCTN_Code_TTT_1AR_2AG
-
References
- 1 Ryu CH, Lee SK. Biliary strictures after liver transplantation. Gut Liver 2011; 5: 133-142
- 2 Seehofer D, Eurich D, Veltzke-Schlieker W et al. Biliary complications after liver transplantation: old problems and new challenges. Am J Transplant 2013; 13: 253-265
- 3 Ayoub WS, Esquivel CO, Martin P. Biliary complications following liver transplantation. Dig Dis Sci 2010; 55: 1540-1546