Kinder- und Jugendmedizin 2006; 06(01): 43-48
DOI: 10.1055/s-0037-1617889
Neugeborenen-Screening
Schattauer GmbH

Neugeborenen-Screening mittels Tandem-Massenspektrometrie

Neue Fragestellungen durch den Nachweis benigner metabolischer PhänotypenNewborn screening through tandem mass spectrometryCoincidental detection of benign phenotypes of inborn errors of metabolism as a diagnostic and therapeutic challenge
Corina Weigel
1   Kinder- und Jugendklinik des Universitätsklinikums Erlangen (Direktor: Prof. Dr. med. Dr. h.c. W. Rascher)
,
Udo Wendel
2   Universitäts-Kinderklinik Düsseldorf (Direktor: Prof. Dr. med. E. Mayatepek)
,
Fritz-Karl Trefz
3   Kinderklinik Reutlingen (Chefarzt: Prof. Dr. med. F.-K. Trefz)
,
Dagmar Scheible
3   Kinderklinik Reutlingen (Chefarzt: Prof. Dr. med. F.-K. Trefz)
,
Claudia Haase
4   Klinik für Kinder- und Jugendmedizin der Friedrich-Schiller-Universität Jena (Direktor: Prof. Dr. med. F. Zintl)
,
Wolfgang Rascher
1   Kinder- und Jugendklinik des Universitätsklinikums Erlangen (Direktor: Prof. Dr. med. Dr. h.c. W. Rascher)
,
Ina Knerr
1   Kinder- und Jugendklinik des Universitätsklinikums Erlangen (Direktor: Prof. Dr. med. Dr. h.c. W. Rascher)
› Author Affiliations
Further Information

Publication History

Eingegangen: 17 May 2005

angenommen: 24 May 2005

Publication Date:
12 January 2018 (online)

Zusammenfassung

Der Einsatz der Tandem-Massenspektrometrie (Tandem-MS) im erweiterten Neugeborenen-Screening ermöglicht die Erfassung einer Vielzahl angeborener Stoffwechselerkrankungen. Durch die frühzeitige Befunderhebung können bei den betroffenen Kindern eine rasche Konfirmationsdiagnostik und spezifische Behandlung durchgeführt werden. Die Tandem-MS erfasst allerdings aufgrund ihrer hohen Sensitivität auch asymptomatische Kinder mit benignen metabolischen Varianten, die primär nicht therapiepflichtig sind. Die Stratifizierung weiterer Maßnahmen anhand der erhobenen Befundkonstellation aus dem Tandem- MS-Neugeborenen-Screening stellt eine neue diagnostische und therapeutische Situation dar, verglichen mit dem konventionellen Neugeborenen-Screening und dem selektiven Stoffwechsel-Screening. Prinzipiell sollten nur die Kinder, die an einer therapiepflichtigen Stoffwechselerkrankung leiden, einer spezifischen Behandlung zugeführt werden, und diejenigen fundiert beraten werden, deren Befundkonstellation als benigner Phänotyp klassifiziert werden kann. Langzeitstudien sind jedoch erforderlich, um klinisch benigne Varianten metabolischer Störungen sicher als solche klassifizieren zu können.

Summary

Tandem mass spectrometry (tandem-MS) enables the detection of a large variety of inborn errors of metabolism (IEOM) in newborns. Early diagnosis due to the extreme sensitivity of this method allows a rapid detection of IEOM in affected children which can then be confirmed by further diagnostics followed by the initiation of therapy. However, this method also detects mild variants of IEOM, classified as benign phenotypes, where treatment is not considered necessary. It is of paramount importance, therefore, to stratify subsequent diagnostic and therapeutic procedures following newborn screening with tandem-MS, since this method, used in healthy children, allows a different diagnostic approach compared to conventional newborn screening or selective metabolic screening. Those children suffering from an IEOM needing treatment must be differentiated from newborns with mild phenotypes. Comprehensive information is therefore imperative. In addition, long-term follow-up studies are necessary for a correct classification of benign phenotypes.

 
  • Literatur

  • 1 Gibson KM, Bennett MJ, Naylor EW, Morton DH. 3-Methylcrotonyl-coenzyme A carboxylase deficiency in Amish/Mennonite adults identified by detection of increased acylcarnitines in blood spots of their children. J Pediatr 1998; 132: 519-23.
  • 2 Harms E, Roscher AA, Grüters A. et al. Richtlinien zur Organisation und Durchführung des Neugeborenen-screenings auf angeborene Stoffwechselstörungen und Endokrinopathien in Deutschland. Monatsschr Kinderheilkd 2002; 150: 1424-40.
  • 3 Koeberl DD, Millington DS, Smith WE. et al. Evaluation of 3-methylcrotonyl-CoA carboxylase deficiency detected by tandem mass spectrometry newborn screening. J Inherit Metab Dis 2003; 26: 25-35.
  • 4 Lehotay DC, LePage J, Thompson JR, Rockman-Greenberg C. Blood acylcarnitine levels in normal newborns and heterozygotes for medium-chain acyl-CoA dehydrogenase deficiency: A relationship between genotype and biochemical phenotype. J Inherit Metab Dis 2004; 27: 81-8.
  • 5 Liebl B, von Kries R, Nennstiel-Ratzel U. et al. Ethisch-rechtliche Aspekte des Neugeborenen-screenings. Monatsschr Kinderheilkd 2001; 149: 1326-35.
  • 6 Liebl B, Muntau AC, Fingerhut R. et al. Durchführung der Untersuchung. In: Screening-Handbuch (Fachschrift zum Neugeborenen-Screening auf angeborene Stoffwechselstörungen und Endokrinopathien). Heilbronn: SPS Verlagsgesellschaft mbH; 2002: 14-9.
  • 7 Liebl B, Nennstiel-Ratzel U, von Kries R, Roscher AA. Abschlußbericht zum Modellprojekt zur Neuordnung des Neugeborenen-Screenings in Bayern, Fachinformation vom Bayerischen Landesamt für Gesundheit und Lebensmittelsicherheit. http://www.lgl.bayern.de/de/left/fachinformationen/gesundheit 2001
  • 8 Müller-Sinik K, Haverkamp F. Psychosoziale Auswirkungen des Neugeborenen-Screenings auf die Eltern und Konsequenzen für die ärztliche Betreuung. In: Zabransky S. (Hrsg) Screening auf angeborene endokrine und metabole Störungen. Wien, New York: Springer; 2001: 24-33.
  • 9 Nelson RM, Botkin JR, Kodish ED. et al. Ethical issues with genetic testing in pediatrics. Pediatrics 2001; 107: 1451-5.
  • 10 Plöchl E, Plöchl W, Wermuth B, Roscher AA. Varianten angeborener Stoffwechselstörungen mit spätem Beginn, aber bedrohlichem Verlauf. Klin Padiatr 2001; 213: 261-5.
  • 11 Statistisches Bundesamt, Pressestelle. Geringfügig weniger Geburten, mehr Sterbefälle im Jahr 2002. http://www.destatis.de/presse 2003
  • 12 Zschocke J, Schulze A, Lindner M. et al. Molecular and functional characterisation of mild MCAD deficiency. Hum Genet 2001; 108: 404-8.