Subscribe to RSS
DOI: 10.1055/s-0040-1704170
RECANALIZATION OF ESOPHAGEAL OCCLUSION BY ELECTROCAUTERY ENHANCED ENDOSCOPIC RENDEZ-VOUS
Publication History
Publication Date:
23 April 2020 (online)
A gastroscope was introduced per os, and an ultrathin gastroscope was introduced retrogradely, until esophageal occlusion.
After transillumination and X-Ray guided endoscopic alignment, a tunnel through the disconnected esophagus was performed using the electrocautery of “Hot Axios” stent. Axios stent was deployed but the proximal flange dislodged. A guide wire was introduced and a balloon dilation was performed.
The axios stent was removed and a fully covered stent was deployed, left in place for 4 months and withdrawn with “stent in stent” technique. Despite oral steroids, an esophageal stricture developed, that was solved with 4 dilation sessions and intralesional steroids.