Endosc Int Open 2016; 04(02): E190-E192
DOI: 10.1055/s-0041-109400
Case report
© Georg Thieme Verlag KG Stuttgart · New York

A novel wide viewing endoscope for upper gastrointestinal screening: a pilot study

Naomi Kakushima
Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
,
Kohei Takizawa
Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
,
Masaki Tanaka
Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
,
Noboru Kawata
Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
,
Sayo Ito
Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
,
Kenichiro Imai
Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
,
Kinichi Hotta
Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
,
Kimihiro Igarashi
Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
,
Yoshihiro Kishida
Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
,
Masao Yoshida
Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
,
Hiroyuki Matsubayashi
Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
,
Hiroyuki Ono
Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
› Author Affiliations
Further Information

Publication History

submitted 04 September 2015

accepted after revision 04 November 2015

Publication Date:
04 February 2016 (online)

The feasibility of full-spectrum endoscopy (FUSE) esophagogastroduodenoscopy (EGD), providing a 245-degree field of view with double imagers on the front and left side of the endoscope was evaluated. Twenty-one healthy individuals (15 male, median age, 35 years) underwent upper gastrointestinal screening using FUSE-EGD. The primary end point was the rate of successful visualization of Vater’s papilla. Secondary end points were visualization of the squamo-columnar junction (SCJ) and the anal side of the pyloric ring, and the endoscopists’ subjective evaluation of usability based on maneuverability and imaging of FUSE-EGD. The mean procedure time was 6.5 min, with a median of 91 images captured. The rate of successful visualization of Vater’s papilla was 90 % (19/21). The whole circumference of the SCJ was observed with two video monitors in all cases. The anterior anal side of the pyloric ring was observed in 29 % (6/21) of cases. However, the general impression of the usability of FUSE-EGD was that it was rather inferior to that of a standard front viewing endoscope. Although the usability requires further modification, FUSE-EGD provided excellent results for imaging Vater’s papilla and the SCJ.

 
  • References

  • 1 Hew WY, Joo KR, Cha JM et al. Feasibility of forward-viewing upper endoscopy for detection of the major duodenal papilla. Dig Dis Sci 2011; 56: 2895-2899
  • 2 Gralnek IM, Carr-Locke DL, Segol O et al. Comparison of standard forward-viewing mode versus ultrawide-viewing mode of a novel colonoscopy platform: a prospective, multicenter study in the detection of simulated polyps in an in vitro colon model (with video). Gastrointest Endosc 2013; 77: 472-479
  • 3 Gralnek IM, Segol O, Suissa A et al. A prospective cohort study evaluating a novel colonoscopy platform featuring full-spectrum endoscopy. Endoscopy 2013; 45: 697-702
  • 4 Gralnek IM, Siersema PD, Halpern Z et al. Standard forward-viewing colonoscopy versus full-spectrum endoscopy: an international, multicenter, randomized, tandem colonoscopy trial. Lancet Oncol 2014; 15: 353-360
  • 5 Kong H, Kim YS, Hun JJ et al. Limited ability of capsule endoscopy to detect normally positioned duodenal papilla. Gastrointest Endosc 2006; 64: 538-541
  • 6 Burke CA, Beck GJ, Church JM et al. The history of untreated duodenal and ampullary adenomas in patients with familial adenomatous polyposis followed in an endoscopic surveillance program. Gastrointest Endosc 1999; 49: 358-364
  • 7 Saurin JC, Gutknecht C, Napoleon B et al. Surveillance of duodenal adenomas in familial adenomatous polyposis reveals high cumulative risk of advanced disease. J Clin Oncol 2004; 22: 493-498