Closure of duodenal ulcer perforation using a novel endoloop device with a single-channel gastroscope after failed laparoscopic repair

Shu Huang
1   Medical Center for Digestive Diseases, People’s Hospital of Lianshui, Huaian, China
,
Sumin Zhu
2   Medical Center for Digestive Diseases, The Second Affiliated Hospital, Nanjing Medical University, Nanjing, China
› Author Affiliations
Further Information

Publication History

Publication Date:
09 January 2017 (online)

Patients with duodenal ulcer perforation regularly undergo conversion to open surgical repair after the failure of laparoscopic closure [1]. We report the use of a novel endoloop device with a single-channel gastroscope for the closure of a duodenal ulcer perforation after failed laparoscopic repair.

A 76-year-old man underwent laparoscopic repair of a perforated duodenal bulb ulcer. However, he presented with abdominal pain and fever 8 days after surgery. Gastroscopy revealed a perforation of approximately 1.0 cm in size located at the anterior wall of the duodenal bulb ([Fig. 1]). A novel LeCamp endoloop ([Fig. 2]; Leo Medical, Changzhou, China) was inserted into the duodenal bulb by forceps through the single-channel therapeutic endoscope. After adjustment of the endoloop’s location and angle, it was anchored onto the full thickness of the edge of the perforation with the clip ([Fig. 3 a]). Several additional clips were then inserted to hold the endoloop at different sides of the margin ([Fig. 3 b]). The delivery system was then inserted. The removable hook ([Fig. 3 c]) was connected with the endoloop, which was tightened by slight pulling together of all the clips ([Fig. 3 d]). The delivery system was subsequently removed from the endoloop and the perforation was completely closed. A gastroduodenal decompression tube was placed as the last step ([Fig. 3 e]). With relieved abdominal pain and fever, the patient’s postoperative recovery was uneventful.

Zoom Image
Fig. 1 A large perforation of an ulcer located at the anterior wall of the duodenal bulb after the failure of laparoscopic closure in a 76-year-old man.
Zoom Image
Fig. 2 The LeCamp endoloop.
Zoom Image
Fig. 3 Closure of duodenal ulcer perforation after failed laparoscopic repair using the novel endoloop with a single-channel gastroscope. a The endoloop was inserted into the duodenal bulb by forceps through the single-channel therapeutic endoscope. b Additional clips were used to hold the endoloop at different points on the edge of the perforation. c The removable hook that was connected to the endoloop. d Successful closure of the perforation following tightening of the endoloop by slight pulling together of all the edges. e A gastroduodenal decompression tube was placed as the last step.
Video 1: A novel endoloop and metallic clips used with a single-channel gastroscope to close perforation of a duodenal ulcer after failed laparoscopic repair in a 76-year-old man.

Quality:

The LeCamp ligation device – a novel endoscopic product using the purse-string suture idea – has been developed from the method for closing larger perforations that used a nylon loop combined with hemostatic clips. It can be applied easily using the single working channel of conventional endoscopes and its loop does not need to be preloaded prior to insertion. The LeCamp endoloop significantly facilitates the accurate closure of lesion defects resulting from endoscopic full-thickness resection [2]. In the case described here, we used the novel endoloop and metallic clips with a single-channel gastroscope to close a duodenal ulcer perforation after failed laparoscopic repair, which suggests that this new technique may be a simple and feasible method for closure of perforations in the gastrointestinal tract.

Endoscopy_UCTN_Code_TTT_1AO_2AC

 