Background and Study Aims: Impacted sharp foreign bodies in the esophagus can be very
difficult to manage. When attempts are made to remove such objects inappropriately,
life-threatening complications such as perforation can occur. The aim of this study
was to evaluate the safety and efficacy of endoscopic removal of impacted sharp foreign
bodies in the esophagus using proximal dilatation with an oral side balloon or transparent
cap.
Patients and Methods: A total of 22 patients (10 men, 12 women) with impacted sharp
foreign bodies in the esophagus underwent endoscopic extraction. The following technique
was successfully performed at our hospital. An oral side balloon (Top Co., Japan)
for esophageal variceal sclerotherapy was attached to the distal part of the endoscope.
With the patient under local anesthesia, the endoscope was inserted as far as the
proximal part of the esophageal foreign body. The oral side balloon was then gradually
inflated. Dilatation of the proximal part of the esophagus made it possible to release
the impacted sharp foreign body from the esophageal wall. A transparent cap was used
for foreign bodies in the upper esophagus when there were difficulties with the oral
side balloon.
Results: The types of foreign body removed were fish bones (n = 9), press-through
packages (n = 8), chicken bones (n = 3), dentures (n = 1), and a wrist watch (n =
1). Endoscopic removal was successful in all but one of the cases, in which a fish
bone had to be extracted surgically.
Conclusions: The proximal dilatation method using an oral side balloon or transparent
cap is safe and effective in removing sharp foreign bodies from the esophagus, avoiding
surgery and possible perforation.
References
- 1
Moon J S, Kim Y H, Son T J, et al.
The foreign bodies in the upper gastrointestinal tract diagnosed by endoscopy.
Korean J Gastrointest Endosc.
1990;
10
305-315
- 2
Webb W A.
Management of foreign bodies of the upper gastrointestinal tract.
Gastroenterology.
1988;
94
204-216
- 3 Webb W A, Taylor M B.
Foreign bodies of the upper gastrointestinal tract. In: Taylor MB, Gollan JL, Steer ML, Wolfe M (eds). Gastrointestinal emergencies.
Baltimore; Williams and Wilkins 1997 2nd ed: 3-18
- 4
Webb W A.
Management of foreign bodies of the upper gastrointestinal tract: update.
Gastrointest Endosc.
1995;
41
39-51
- 5
Schwartz G F, Polsky H S.
Ingested foreign bodies of the gastrointestinal tract.
Am Surg.
1976;
42
236-238
- 6 Yoshida C, Peura D.
Foreign bodies in the esophagus. In: Castell DO (ed). The esophagus. Boston; Little, Brown 1995 2nd ed: 379-394
- 7
Holinger L D.
Management of sharp and penetrating foreign bodies of the upper aerodigestive tract.
Ann Otol Rhinol Laryngol.
1990;
99
684-688
- 8
Bertoni G, Pacchione D, Conigliaro R, et al.
Endoscopic protector hood for safe removal of sharp-pointed gastroesophageal foreign
bodies.
Surg Endosc.
1992;
6
255-258
- 9
Lee M S, Ra D J, Kim J H, et al.
A review of the endoscopic extraction in 52 cases of the upper gastrointestinal foreign
bodies.
Korean J Gastrointest Endosc.
1990;
10
47-52
- 10
Berggreen P J, Harrison E, Sanowski R A, et al.
Techniques and complications of esophageal foreign body extraction in children and
adults.
Gastrointest Endosc.
1993;
39
626-630
- 11
Chaikhouni A, Kratz J M, Crawford F A.
Foreign bodies of the esophagus.
Am Surg.
1985;
51
173-179
- 12
Maleki M, Evans W E.
Foreign body perforation of the intestinal tract: report of 12 cases and review of
the literature.
Arch Surg.
1970;
101
475-477
- 13
Taylor R B.
Esophageal foreign bodies.
Emerg Med Clin North Am.
1987;
5
301-311
- 14
Clarkston W.
Gastrointestinal foreign bodies.
Postgrad Med.
1992;
92
46-48
- 15
Gryboski D M, Ballou L H, Cunningham J T.
Endoscopic identification and removal of an unusual symptomatic esophageal foreign
body.
Am J Gastroenterol.
1996;
91
1639-1640
- 16
Tsutsui S, Masuda T, Matsuda H, et al.
Removal of a press-through package in the thoracic esophagus using two flexible Endoscopes.
Endoscopy.
1993;
25
374-375
- 17
Tuen H H, Lai E C, Fan S T.
Endoscopic retrieval of ingested broken glass in the esophagus and stomach by end-hood
and suction technique.
Gastrointest Endosc.
1989;
35
357-358
- 18
Spurling T J, Zaloga G P, Richter J E.
Fiberendoscopic removal of a gastric foreign body with overtube technique.
Gastrointest Endosc.
1983;
20
226-227
- 19
Witzel L, Scheurer U, Muhlemann A, Halter F.
Removal of razor blades from stomach with fiberoptic endoscope.
Br Med J.
1974;
2
539
- 20
Rogers B HG, Kot C, Meiri S, Epstein M.
An overtube for the flexible fiberoptic esophagogastroduodenoscope.
Gastrointest Endosc.
1983;
28
256-257
- 21 Katayama S.
Removal of foreign body of esophagus and stomach: balloon method. In: Suzuki H (ed). Pitfalls and knack in gastrointestinal endoscopy. Tokyo; Nakayama,
1999 2nd ed: 62-63
- 22
Mamel J J, Weiss D, Pouagare M, Nord H J.
Endoscopic suction removal of food boluses from the upper gastrointestinal tract using
Stiegmann-Goff friction-fit adaptor: an improved method for removal of food impactions.
Gastrointest Endosc.
1995;
41
593-596
J. H. Hyun, M.D.
Dept. of Gastroenterology
Korea University Hospital
126-1, 5-Ga, Anam-Dong
Seongbuk-Gu
Seoul, 136-705
Korea
Fax: Fax:+ 82-2-953-1943
Email: E-mail:kumcge@chollian.net