Endoscopy 2003; 35(2): 181-184
DOI: 10.1055/s-2003-37015
Case Report
© Georg Thieme Verlag Stuttgart · New York

Newly Developed 3D Endoscopic System: Preliminary Experience

T.  Yoshida1 , H.  Inoue1 , E.  Hara1 , A.  Umezawa1 , K.  Ohtsuka1 , S.  Endo1 , Y.  Tamegai1 , H.  Kashida1 , J.  Tanaka1 , S.  Kudo1
  • 1Digestive Disease Center, Showa University Northern Yokohama Hospital, Yokohama, Japan
Further Information

Publication History

Submitted: 27 December 2001

Accepted after Revision: 8 October 2002

Publication Date:
30 January 2003 (online)

Although there have been earlier reports on the use of three-dimensional endoscopic systems in the gastrointestinal tract, real-time three-dimensional imaging has not previously been described. This paper presents experience in three cases with a novel endoscopic system for three-dimensional observation in clinical situations. Case 1 was a hyperplastic gastric polyp, the shape of which was considerably enhanced in comparison with two-dimensional endoscopic viewing. Case 2 was an advanced esophageal cancer, in which the sense of depth was improved in the esophagus. Case 3 was a depressed early gastric cancer, the shape of which was also enhanced. Between July 2001 and March 2002, three experienced endoscopists also used this new system in a further 34 patients. A three-dimensional endoscopic environment was visible with the system in all patients, and all of the endoscopists were able to obtain visual information regarding spatial depth. This experience suggests that the three-dimensional video-endoscopic system used here can be of value in gastrointestinal endoscopy.

References

  • 1 Catalano M F, van Dam J, Bedford R. et al . Preliminary evaluation of the prototype stereoscopic endoscope: precise three-dimensional measurement system.  Gastrointest Endosc. 1993;  39 23-28
  • 2 Yao K, Furukawa H, Matsui T, Yao T. A new stereo-endoscopic system: precise three-dimensional measurement; in vitro basic study [abstract].  Gastrointest Endosc. 2001;  53 AB115
  • 3 Yao K, Furukawa H, Matsui T. et al . Clinical usefulness for measuring the gastric lesion size by a new stereo-endoscopic system: the first report of in vivo study [abstract].  Gastrointest Endosc. 2001;  53 AB112
  • 4 Yoshida T, Inoue H, Iwai T. A new face-mounted display system: pilot trial of clinical application in therapeutic endoscopy.  Endoscopy. 2000;  32 974-976
  • 5 Zobel J. Basics of three-dimensional endoscopic vision.  Endosc Surg Allied Technol. 1993;  1 36-39
  • 6 Taffinder N, Smith S GT, Huber J. et al . The effect of a second-generation 3D endoscope on the laparoscopic precision of novices and experienced surgeons.  Surg Endosc. 1999;  13 1087-1092
  • 7 Yoshida T, Inoue H, Kumagai Y, Iwai T. Image-navigated endoscopic surgery: introduction of the face-mounted display system with picture-in-picture capabilities.  Hepatogastroenterology. 2000;  47 375-377

T. Yoshida, M.D.

Digestive Disease Center · Showa University Northern Yokohama Hospital ·

35-1, Chigasaki-chuo, Tsuzuki-ku · Yokohama 224-8503 · Japan

Fax: + 81-45-949-7927 ·

Email: t.yoshida@libra.bekkoame.ne.jp

    >