Sleep Breath 2003; 07(2): 087-094
DOI: 10.1055/s-2003-40666
Copyright © 2003 by Thieme Medical Publishers, Inc., 333 Seventh Avenue, New York, NY 10001, USA. Tel.: +1(212) 584-4662

Nasal Breathing and Continuous Positive Airway Pressure (CPAP) in Patients with Obstructive Sleep Apnea (OSA)

Jan H. Hollandt, Malte Mahlerwein
  • Klinik für Hals-, Nasen- und Ohrenheilkunde, Universitätsklinikum Schleswig-Holstein, Campus Lübeck, Germany
Further Information

Publication History

Publication Date:
14 July 2003 (online)

ABSTRACT

Although nasal continuous positive airway pressure (nCPAP) treatment is the most efficient therapy for obstructive sleep apnea (OSA), compliance with therapy is poor because of several side effects. Among these adverse effects some are related to the reactions of the nose to nCPAP which are briefly described. In a long-term survey of 109 OSA patients, 80.6% continued nCPAP for at least 3 years until the last follow-up. Follow-up ranged between 0.8 and 109 months with a mean time of 43 (SD ± 24.7) months. Among all patients treated with nCPAP, only 46.6% met our criteria for long-term compliance, defined as a mean use of the CPAP machine for at least 5 hours per night. Within the objective measures such as age, body mass index, neck circumference, nasal airflow, apnea-hypopnea index, minimal oxygen saturation, and level of nCPAP pressure, no predictive factor for daily use of nCPAP could be found. However, pretherapeutic daytime somnolence (measured by visual analogue scale and Epworth Sleepiness Scale) and its improvement obtained from the therapy showed a significant effect on the daily use of the CPAP machine.

REFERENCES

  • 1 Sullivan C E, Berthon-Jones M, Issa F G, Evers L. Reversal of obstructive sleep apnoea by continuous positive airway pressure applied through the nares.  Lancet . 1981;  1 862-865
  • 2 Jenkinson C, Davies R JO, Stradling J R. Comparison of therapeutic and subtherapeutic nasal continuous positive airway pressure for obstructive sleep apnea: a randomized prospective parallel trial.  Lancet . 1999;  353 2100-2105
  • 3 Ballester E, Badia J R, Hernandez L. et al . Evidence of effectiveness of continuous positive airway pressure in the treatment of sleep apnea/hypopnea syndrome.  Am J Respir Crit Care Med . 1999;  159 495-501
  • 4 Brandenburg U, Weiner M, Becker J. et al . Haemodynamics and sleep structure in the discontinued nCPAP test in obstructive sleep apnoea syndrome [German].  Pneumologie . 1993;  47 181-183
  • 5 Krieger J, Weitzenblum E, Monassier J P, Stoeckel C, Kurtz D. Dangerous hypoxemia during continuous positive airway pressure treatment of obstructive sleep apnea [letter].  Lancet . 1983;  2 1429-1430
  • 6 Anderson A P, Alving J, Lildholdt T, Wulff C. Obstructive sleep apnea initiated by a lax epiglottis: a contraindication for continuous positive airway pressure.  Chest . 1987;  91 621-623
  • 7 Pépin J L, Leger P, Veale D. et al . Side effects of nasal continuous positive airway pressure in sleep apnea syndrome. Study of 193 patients in two French sleep centers.  Chest . 1995;  107 375-381
  • 8 Strumpf D A, Harrop P, Dobbin J, Millman R P. Massive epistaxis from nasal CPAP therapy.  Chest . 1989;  95 1141
  • 9 Jarjour N N, Wilson P. Pneumocephalus associated with nasal continuous positive airway pressure in a patient with sleep apnea syndrome.  Chest . 1989;  96 1425-1426
  • 10 Bamford C R, Quan S F. Bacterial meningitis-a possible complication of nasal continuous positive airway pressure therapy in a patient with obstructive sleep apnea syndrome and a mucocele.  Sleep . 1993;  16 31-32
  • 11 Zwacka G, Scholle S, Kemper G, Rieger B. Nasal CPAP therapy for infants with congenital stridor.  Sleep Breath. 1997/98;  2 085-096
  • 12 Loftus B C, Ahn J, Haddad J. Neonatal nasal deformities secondary to nasal continuous positive airway pressure.  Laryngoscope. 1994;  104 1019-1022
  • 13 Mortimore I L, Whittle A T, Douglas N J. Comparison of nose and face mask CPAP therapy for sleep apnoea.  Thorax . 1998;  53 290-292
  • 14 Verse T. Nebenwirkungen der nasalen CPAP-Ventilationstherapie.  HNO . 2000;  48 706-715
  • 15 Verse T, Lehnhardt E, Pirsig W, Junge-Hülsing B, Kroker B. Otorhinolaryngological side effects of nocturnal nasal ventilation therapy with continuous positive airway pressure (nCPAP).  Laryngorhinootologie . 1999;  78 491-496
  • 16 Wiest G H, Ficker J H, Müller A, Hahn E G. Nebenwirkungen der nCPAP-Therapie beim obstruktiven Schlafapnoesyndrom. Ursachen und Therapie.  Atemw-Lungenkrkh . 1998;  24 95-102
  • 17 Lojander J, Brander P E, Ämmälä K. Nasopharyngeal symptoms and nasal continuous positive airway pressure therapy in obstructive sleep apnea syndrome.  Acta Otolaryngol . 1999;  119 497-502
  • 18 Kalan A, Kenyon G S, Seemungal T AR, Wedzicha A. Adverse effects of positive airway pressure therapy in sleep apnoea syndrome.  J Laryngol Otol . 1999;  113 888-892
  • 19 Nino-Murcia G, McCann C C, Bliwise D L, Guilleminault C, Dement W C. Compliance and side effects in sleep apnea patients treated with nasal continuous positive airway pressure.  West J Med . 1989;  150 165-169
  • 20 Togias A G, Naclerio R M, Proud D. et al . Nasal challenge with cold, dry air results in release of inflammatory mediators: possible mast cell involvement.  J Clin Invest . 1985;  76 1375-1381
  • 21 Constantinidis J, Knöbber D, Steinhart H, Kuhn J, Iro H. Fine-structural investigations of the effect of nCPAP-mask application on the nasal mucosa.  Acta Otolaryngol . 2000;  120 432-437
  • 22 Richards G N, Cistulli P A, Ungar R G, Berthon-Jones M, Sullivan C E. Mouth leak with nasal continuous positive airway pressure increases nasal airway resistance.  Am J Respir Crit Med . 1996;  154 182-186
  • 23 Becker H, Fett I, Nees E, Peter J H, von Wichert P. Behandlung primärer und sekundärer Therapieversager der nCPAP-Behandlung bei Patienten mit Schlafapnoe.  Pneumologie . 1991;  45 301-305
  • 24 Wiest G H, Lehnert G, Brück W M. et al . A heated humidifier reduces upper airway dryness during continuous positive airway pressure therapy.  Resp Med . 1999;  93 21-26
  • 25 Grunstein R R. Sleep-related breathing disorders. 5. Nasal continuous positive airway pressure treatment for obstructive sleep apnea.  Thorax . 1995;  50 1106-1113
  • 26 Coppola M P. Controversies in sleep medicine-essay: The Emperor (and my patient) has no nose.  Sleep Breath . 1999;  3 107
  • 27 Massie C A, Hart R W, Peralez K, Richards G N. Effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure.  Chest . 1999;  116 403-408
  • 28 Krieger J, Kurtz D. Objective measurement of compliance with nasal CPAP treatment for obstructive sleep apnoea syndrome.  Eur Respir J . 1988;  1 436-438
  • 29 Waldhorn R E, Herrick T W, Nguyen M C. et al . Long-term compliance with nasal continuous positive airway pressure therapy of obstructive sleep apnea.  Chest . 1990;  97 33-38
  • 30 Rauscher H, Popp W, Wanke T, Zwick H. Acceptance of CPAP therapy for sleep apnea.  Chest . 1991;  100 1019-1023
  • 31 Hoffstein V, Viner S, Mateika S, Conway J. Treatment of obstructive sleep apnea with nasal continuous positive airway pressure. Patient compliance, perception of benefits, and side effects.  Am Rev Respir Dis . 1992;  145 841-845
  • 32 Engleman H M, Martin S E, Douglas N J. Compliance with CPAP-therapy in patients with sleep apnea/hypopnea syndrome.  Thorax . 1994;  49 263-266
  • 33 Hollandt J H, Kuhl S, Siegert R. Treatment of patients with the obstructive sleep apnoea syndrome (OSAS) using nasal continuous positive airway pressure (nCPAP). Part I: Long-term compliance with nCPAP.  Laryngorhinootologie . 1997;  76 550-553
  • 34 Partinen M, Jamieson A, Guilleminault C. Long-term outcome for obstructive sleep apnea syndrome patients' mortality.  Chest . 1988;  94 1200-1204
  • 35 Rasche K, Orth M, Duchna H W, Ullrich H W, Schultze-Werninghaus G. CPAP-Therapie bei obstruktivem Schlafapnoesyndrom: Nebenwirkungen und Akzeptanz im Langzeitverlauf.  Med Klinik . 1994;  89 86-88
  • 36 Kuhl S, Hollandt J H, Siegert R. Treatment of patients with obstructive sleep apnea syndrome (OSAS) with nasal continuous positive airway pressure (nCPAP). Part II: Side effects of nCPAP therapy-influence on long-term compliance.  Laryngorhinootologie . 1997;  76 608-613
  • 37 Hollandt J H, Mahlerwein M, Klaiber S, Siegert R. Langzeitakzeptanz von nCPAP (nasal continuous positive airway pressure) bei Patienten mit obstruktivem Schlafapnoe Syndrom [abstract].  HNO Informationen . 2002;  27 136
  • 38 Johns M W. Reliability and factor analysis of the Epworth Sleepiness Scale.  Sleep . 1992;  15 376-381
  • 39 Meurice J C, Dore P, Paquereau J. et al . Predictive factors of long-term compliance with nasal continuous positive airway pressure treatment in sleep apnea syndrome.  Chest . 1994;  105 429-433
  • 40 Mayer-Brix J, Becker H, Peter J H. Nasal high pressure ventilation in obstructive sleep apnea syndrome. Theoretical and practical otorhinolaryngological aspects [German].  Laryngorhinootologie . 1989;  68 295-298
  • 41 Sériès F; Pierre S S, Carrier G. Effects of surgical correction of nasal obstruction in the treatment of obstructive sleep apnea.  Am Rev Respir Dis . 1992;  146 1261-1265
  • 42 Ripberger R, Pirsig W. Long-term compliance with nasal CPAP treatment for obstructive sleep apnoea: prospective study in 50 patients [German].  Laryngorhinootologie . 1994;  73 581-585
  • 43 Friedmann M, Tanyeri H, Lim J W. et al . Effects of improved nasal breathing on obstructive sleep apnea.  Otolaryngol Head Neck Surg . 2000;  122 71-74
  • 44 Biermann E. Nasal CPAP-therapy in obstructive sleep apnea syndrome: does functional rhinosurgery improve compliance?.  Somnologie . 2001;  5 59-64
  • 45 Dorn M, Pirsig W, Verse T. Management of patients with severe obstructive sleep apnea following rhinosurgical interventions. A pilot study.  HNO . 2001;  49 642-645
    >