Endoscopy 2007; 39(10): 876-880
DOI: 10.1055/s-2007-966896
Original article

© Georg Thieme Verlag KG Stuttgart · New York

A new stapler-based full-thickness transgastric access closure: results from an animal pilot trial

P.  Magno1 , S.  A.  Giday2 , X.  Dray1, 2 , S.  S.  Chung3 , P.  B.  Cotton4 , C. J.  Gostout5 , R.  H.  Hawes4 , A.  N.  Kalloo1 , P.  J.  Pasricha6 , J.  J. White7 , L.  Assumpcao8 , M.  R.  Marohn8 , K.  L.  Gabrielson9 , S.  V.  Kantsevoy1
  • 1Division of Gastroenterology, Johns Hopkins Hospital, Baltimore, Maryland, USA
  • 2Department of Digestive Diseases, Lariboisière Hospital, APHP, Paris, France
  • 3Department of Surgery, Prince of Wales Hospital, Hong Kong, China
  • 4Digestive Disease Center, Medical University of South Carolina, Charleston, South Carolina, USA
  • 5Division of Gastroenterology and Hepatology, Mayo Clinic and Foundation, Rochester, Minnesota, USA
  • 6Division of Gastroenterology and Hepatology, Stanford University, Palo Alto, California, USA
  • 7Power Medical Interventions, Langhorne, Pennsylvania, USA
  • 8Department of Surgery, Johns Hopkins Hospital, Baltimore, Maryland, USA
  • 9Department of Molecular and Comparative Pathobiology, Johns Hopkins University, Baltimore, Maryland, USA
Further Information

Publication History

submitted 8 August 2007

accepted after revision 13 August 2007

Publication Date:
29 October 2007 (online)

Background and study aims: Reliable closure of the translumenal incision is the crucial step for natural orifice translumenal endoscopic surgery (NOTES) procedures. The aim of this study was to evaluate the feasibility and effectiveness of transgastric access closure with a flexible stapling device in a porcine survival model.

Patients and methods: We carried out four experiments (two sterile and two nonsterile) on 50 kg pigs. The endoscope was passed through a gastrotomy made with a needle knife and an 18-mm controlled radial expansion dilating balloon. After peritoneoscopy, a flexible linear stapling device (NOLC60, Power Medical Interventions®, Langhorne, Pennsylvania, USA) was perorally advanced over a guide wire into the stomach, positioned under endoscopic guidance, and opened to include the site of gastrotomy between its two arms; four rows of staples were fired. One animal was sacrificed 24 hours after the procedure (progression of pre-existing pneumonia). The remaining animals were survived for 1 week and then underwent repeat endoscopy and postmortem examination.

Results: Peroral delivery and positioning of the stapling device involved some technical difficulties, mostly due to the short length (60 cm) of the stapling device. The stapler provided complete leak-resistant gastric closure in all pigs. None of the surviving animals had any clinical signs of infection. Necropsy demonstrated an intact staple line with full-thickness healing of the gastrotomy in all animals. Histologic examination confirmed healing, but also revealed intramural micro-abscesses within the gastric wall after nonsterile procedure.

Conclusions: Gastrotomy closure with a perorally delivered flexible stapling device created a leak-resistant transmural line of staples followed by full-thickness healing of the gastric wall incision. Increasing the length of the instrument and adding device articulation will further facilitate its use for NOTES procedures.

References

  • 1 Rattner D, Kalloo A. ASGE/SAGES Working Group on Natural Orifice Translumenal Endoscopic Surgery. October 2005.  Surg Endosc. 2006;  20 329-333
  • 2 Swanstrom L L, Kozarek R, Pasricha P J. et al . Development of a new access device for transgastric surgery.  J Gastrointest Surg. 2005;  9 1129-1137
  • 3 Lamade W, Hochberger J. Transgastric surgery: avoiding pitfalls in the development of a new technique.  Gastrointest Endosc. 2006;  63 698-700
  • 4 Kantsevoy S V. Endoscopic full-thickness resection: new minimally invasive therapeutic alternative for GI-tract lesions.  Gastrointest Endosc. 2006;  64 90-91
  • 5 Fritscher-Ravens A. Transgastric endoscopy - a new fashion, a new excitement!.  Endoscopy. 2007;  39 161-167
  • 6 Kaehler G F, Langner C, Suchan K L. et al . Endoscopic full-thickness resection of the stomach: an experimental approach.  Surg Endosc. 2006;  20 519-521
  • 7 Kaehler G, Grobholz R, Langner C. et al . A new technique of endoscopic full-thickness resection using a flexible stapler.  Endoscopy. 2006;  38 86-89
  • 8 Kalloo A N, Singh V K, Jagannath S B. et al . Flexible transgastric peritoneoscopy: a novel approach to diagnostic and therapeutic interventions in the peritoneal cavity.  Gastrointest Endosc. 2004;  60 114-117
  • 9 Wagh M S, Merrifield B F, Thompson C C. Endoscopic transgastric abdominal exploration and organ resection: initial experience in a porcine model.  Clin Gastroenterol Hepatol. 2005;  3 892-896
  • 10 Raju G S, Ahmed I, Shibukawa G. et al . Endoluminal clip closure of a circular full-thickness colon resection in a porcine model (with videos).  Gastrointest Endosc. 2007;  65 503-509
  • 11 Hu B, Kalloo A N, Chung S S. et al . Peroral transgastric endoscopic primary repair of a ventral hernia in a porcine model.  Endoscopy. 2007;  39 390-393
  • 12 Park P O, Bergstrom M, Ikeda K. et al . Experimental studies of transgastric gallbladder surgery: cholecystectomy and cholecystogastric anastomosis (videos).  Gastrointest Endosc. 2005;  61 601-606
  • 13 Ikeda K, Mosse A, Park P O. et al . Endoscopic full-thickness resection (EFTR): circumferential cutting method.  Gastrointest Endosc. 2006;  64 82-89
  • 14 Raju G S, Shibukawa G, Ahmed I. et al . Endoluminal suturing may overcome the limitations of clip closure of a gaping wide colon perforation (with videos).  Gastrointest Endosc. 2007;  65 906-911
  • 15 Wilhelm D, Meining A, Delius S von. et al . An innovative, safe and sterile sigmoid access (ISSA) for NOTES.  Endoscopy. 2007;  39 401-406
  • 16 Ryou M, Pai R, Sauer J. et al . Evaluating an optimal gastric closure method for transgastric surgery.  Surg Endosc. 2007;  21 677-680
  • 17 Kantsevoy S V, Hu B, Jagannath S B. et al . Technical feasibility of endoscopic gastric reduction: a pilot study in a porcine model.  Gastrointest Endosc. 2007;  65 510-513
  • 18 Merrifield B F, Wagh M S, Thompson C C. Peroral transgastric organ resection: a feasibility study in pigs.  Gastrointest Endosc. 2006;  63 693-697
  • 19 Pai R D, Fong D G, Bundga M E. et al . Transcolonic endoscopic cholecystectomy: a NOTES survival study in a porcine model (with video).  Gastrointest Endosc. 2006;  64 428-434
  • 20 Fong D G, Pai R D, Thompson C C. Transcolonic endoscopic abdominal exploration: a NOTES survival study in a porcine model.  Gastrointest Endosc. 2007;  65 312-318

S. V. Kantsevoy, MD

Division of Gastroenterology

Johns Hopkins Hospital

1830 East Monument Street Room 423

Baltimore, MD 21205

USA

Fax: +1-410-614-2490

Email: svkan@jhmi.edu

    >