Endoscopy 2021; 53(01): 97
DOI: 10.1055/a-1303-9528
COVID-19 communication

Reply to Letter to the Editor, Reply to Yasri & Wiwanitkit

Nikolaos Lazaridis
Royal Free Unit for Endoscopy, The Royal Free Hospital and University College London (UCL) Institute for Liver and Digestive Health, London, United Kingdom
,
Alexandros Skamnelos
Royal Free Unit for Endoscopy, The Royal Free Hospital and University College London (UCL) Institute for Liver and Digestive Health, London, United Kingdom
,
Alberto Murino
Royal Free Unit for Endoscopy, The Royal Free Hospital and University College London (UCL) Institute for Liver and Digestive Health, London, United Kingdom
,
Rocio Chacchi Cahuin
Royal Free Unit for Endoscopy, The Royal Free Hospital and University College London (UCL) Institute for Liver and Digestive Health, London, United Kingdom
,
Nikolaos Koukias
Royal Free Unit for Endoscopy, The Royal Free Hospital and University College London (UCL) Institute for Liver and Digestive Health, London, United Kingdom
,
Edward J. Despott
Royal Free Unit for Endoscopy, The Royal Free Hospital and University College London (UCL) Institute for Liver and Digestive Health, London, United Kingdom
› Institutsangaben
 

We wish to thank Yasri et al. [1] for their interest and discussion regarding our recent publication ‘“Double-surgical-mask-with-slit” method: reducing exposure to aerosol generation at upper gastrointestinal endoscopy during the COVID-19 pandemic’ [2]. As stated in that publication [2], our method adopts the same rationale that governs universal surgical mask use: to reduce airborne exposure to droplets and aerosols by introducing a physical barrier for truncation at source of the “shotgun effect” of aerosol spread [2] [3]. Our method was never designed or claimed to replace other precautionary methods such as the use of any recommended personal protective equipment (PPE) or negative pressure rooms, but only to serve as an additional physical barrier, to potentially further reduce the risk of environmental contamination by fine droplets and aerosols. Through our routine practice, we also note that the “double-surgical-mask-with-slit,” by its design, intrinsically leads to slight misalignment of the slits of the two masks, and this in turn enhances the curtain-like effect of the physical barrier around the scope, which further mitigates any potential “leakage” of droplets.

Although we are confident that with the adoption of increased preprocedural testing of patients for COVID-19, as recommended by more recent guidelines [4], the risk of potential environmental contamination and cross-infection would be reduced even further, it remains our opinion that the use of readily available, inexpensive, additional physical barriers; such as the one described by our group and by others [5], remains worthy of consideration for application in daily clinical practice.


#

Competing interests

Alberto Murino has acted as a consultant for Boston Scientific and GI Supply. He has also received academic grants from Fujifilm, Aquilant Endoscopy, Norgine, and Olympus. Edward J. Despott has acted as a consultant for Boston Scientific and Ambu. He has also received academic grants and speaker honoraria from Fujifilm, Aquilant Endoscopy, Norgine, and Olympus. The other authors declare that they have no conflict of interest.


Corresponding author

Edward J. Despott, MD
Royal Free Unit for Endoscopy
The Royal Free Hospital & University College London (UCL) Institute for Liver and Digestive Health
Pond Street, London, NW3 2QG
United Kingdom
Telefon: +44-207-7940500

Publikationsverlauf

Eingereicht: 18. Oktober 2020

Angenommen: 22. Oktober 2020

Publikationsdatum:
19. November 2020 (online)

© 2020. Thieme. All rights reserved.