Successful re-intervention using endoscopic ultrasound-guided drainage via an endoscopic tapered sheath for recurrent walled-off necrosis with fibrosis
Patients with disconnected pancreatic duct syndrome recur with pancreatic fluid collection in 17–38 % of cases after transmural stent removal [1] [2]. Symptomatic patients require endoscopic re-intervention; however, an approach via the same puncture route is often complicated by fibrosis caused by previous treatment. Long-term placement of a plastic stent is recommended for endoscopic ultrasound-guided drainage of a recurrent walled-off necrosis (WON). However, commonly used pigtail stents are difficult to pass through a fistula even post-dilation, especially in fibrotic cases. Lumen-apposing metal stents can be easily employed in such cases, albeit with an increased risk of serious adverse events in long-term placements [3] [4]. We report a successful re-intervention using endoscopic ultrasound-guided drainage via an endoscopic tapered sheath (EndoSheather; Piolax, Inc., Kanagawa, Japan) ([Fig. 1]) for a recurrent WON with fibrosis.


A 55-year-old man with a previously resolved WON and subsequent transmural stent removal visited our hospital with complaints of high-grade fever and abdominal pain. He was diagnosed with WON recurrence by computed tomography ([Fig. 2]), followed by endoscopic ultrasound-guided drainage ([Video 1]). The procedure involved a WON puncture using a 19-gauge needle and 0.025-inch guidewire, followed by an unsuccessful attempt at catheter insertion into the WON over the guidewire. This was circumvented by breaking the WON wall with a 7-Fr dilator. Thereafter, an endoscopic tapered sheath was inserted, followed by placement of two guidewires. Subsequently, balloon dilatation and placement of a 7-Fr plastic stent were carried out; however, attempts to place the second external drainage tube were unsuccessful. Therefore, we used an endoscopic tapered sheath. As a result, we easily placed a 6-Fr external drainage tube via this device ([Fig. 3]). This device allows easy insertion of medical equipment (up to Ø1.9 mm) through outer sheath ([Fig. 4]). By using this endoscopic tapered sheath, a plastic stent can be easily placed without being affected by fibrosis.


Video 1 Successful re-intervention with endoscopic ultrasound-guided drainage via an endoscopic tapered sheath for recurrent walled-off necrosis with fibrosis.
Quality:




Endoscopy_UCTN_Code_TTT_1AS_2AD
Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply, discounts and wavers acc. to HINARI are available.
This section has its own submission website at https://mc.manuscriptcentral.com/e-videos
#
Competing interests
The authors declare that they have no conflict of interest.
-
References
- 1 Bang JY, Wilcox CM, Navaneethan U. et al. Impact of disconnected pancreatic duct syndrome on the endoscopic management of pancreatic fluid collections. Ann Surg 2018; 267: 561-568
- 2 Arvanitakis M, Delhaye M, Bali MA. et al. Pancreatic-fluid collections: a randomized controlled trial regarding stent removal after endoscopic transmural drainage. Gastrointest Endosc 2007; 65: 609-619
- 3 Bang JY, Navaneethan U, Hasan MK. et al. Non-superiority of lumen-apposing metal stents over plastic stents for drainage of walled-off necrosis in a randomised trial. Gut 2019; 68: 1200-1209
- 4 Brimhall B, Han S, Tatman PD. et al. Increased incidence of pseudoaneurysm bleeding with lumen-apposing metal stents compared to double-pigtail plastic stents in patients with peripancreatic fluid collections. Clin Gastroenterol Hepatol 2018; 16: 1521-1528
Corresponding author
Publication History
Article published online:
30 March 2023
© 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Bang JY, Wilcox CM, Navaneethan U. et al. Impact of disconnected pancreatic duct syndrome on the endoscopic management of pancreatic fluid collections. Ann Surg 2018; 267: 561-568
- 2 Arvanitakis M, Delhaye M, Bali MA. et al. Pancreatic-fluid collections: a randomized controlled trial regarding stent removal after endoscopic transmural drainage. Gastrointest Endosc 2007; 65: 609-619
- 3 Bang JY, Navaneethan U, Hasan MK. et al. Non-superiority of lumen-apposing metal stents over plastic stents for drainage of walled-off necrosis in a randomised trial. Gut 2019; 68: 1200-1209
- 4 Brimhall B, Han S, Tatman PD. et al. Increased incidence of pseudoaneurysm bleeding with lumen-apposing metal stents compared to double-pigtail plastic stents in patients with peripancreatic fluid collections. Clin Gastroenterol Hepatol 2018; 16: 1521-1528