Open Access
CC BY 4.0 · Endoscopy 2023; 55(S 01): E1025-E1026
DOI: 10.1055/a-2113-7732
E-Videos

Successful removal of a biliary metal stent using the stent-in-stent-in-stent technique

Authors

  • Masato Matsuyama

    Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
  • Takeshi Okamoto

    Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
  • Tsuyoshi Takeda

    Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
  • Akiyoshi Kasuga

    Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
  • Takashi Sasaki

    Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
  • Masato Ozaka

    Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
  • Naoki Sasahira

    Department of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
 

A 60-year-old woman with unresectable pancreatic cancer underwent endoscopic biliary stenting with a covered self-expandable metal stent (SEMS) with an antireflux valve ([Fig. 1]). She was readmitted 15 months later due to cholangitis. Cholangiography revealed contrast defect inside the stent, suspected to be the result of tumor invasion. As the stent could not be removed, the stent was trimmed below the ampulla. The removal attempt led to severe biliary hemorrhage that completely obstructed the endoscopic view, and therefore a covered SEMS was deployed under fluoroscopic guidance, leading to successful hemostasis and biliary drainage ([Fig. 2]). The two stents could not be removed when cholangitis recurred just 1 month later, possibly owing to the short duration of the stent-in-stent configuration. Another covered SEMS with an antireflux valve was deployed inside the two existing stents, as the patient clearly had longer time to recurrent biliary obstruction when an antireflux value was present ([Fig. 3]).

Zoom
Fig. 1 Initial placement of a duckbill-type self-expandable metal stent (Duckbill IT Biliary Stent: Kawasumi Laboratories Inc., Tokyo, Japan).
Zoom
Fig. 2 Stent-in-stent placement of a fully covered self-expandable metal stent (HANAROSTENT; Boston Scientific Corp., Marlborough, Massachusetts, USA).
Zoom
Fig. 3 Stent-in-stent-in-stent placement of a duckbill-type self-expandable metal stent (Duckbill Biliary Stent; Kawasumi). The antireflux value can be seen protruding from the second stent.

The patient presented with a third episode of cholangitis 10 months later. Endoscopic retrograde cholangiopancreatography revealed stent obstruction due to biliary stones and debris. When sweeping the lumen of the three stents using stone extraction balloons, all three stents gradually migrated toward the duodenum. We therefore removed all three stents together using an endoscopic snare ([Fig. 4]), which was successfully performed with no resistance ([Fig. 5]). A new laser-cut covered SEMS with an antireflux valve was placed, leading to resolution of the patient’s symptoms ([Video 1]).

Zoom
Fig. 4 Sweeping with a stone extraction balloon (Multi-3V Plus, 15 mm; Olympus Medical Systems Corp., Tokyo, Japan) led to migration of the three stents toward the duodenum.
Zoom
Fig. 5 The stent-in-stent-in-stent complex was removed with a snare.

Video 1 Successful removal of a biliary metal stent using the stent-in-stent-in-stent technique.

Successful removal of both uncovered [1] [2] and covered SEMSs [3] has been reported using the stent-in-stent technique. The duckbill-type stent is a novel covered SEMS with an antireflux valve [4]. The removal of this kind of SEMS can be difficult [4] [5]. When the stent-in-stent technique proves unsuccessful, the addition of a third stent may facilitate removal.

Endoscopy_UCTN_Code_CPL_1AK_2AD

E-Videos is an open access online section of the journal Endoscopy, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/).

This section has its own submission website at https://mc.manuscriptcentral.com/e-videos


Competing interests

The authors declare that they have no conflict of interest.


Corresponding author

Masato Matsuyama, MD, PhD
Department of Hepato-Biliary-Pancreatic Medicine
Cancer Institute Hospital of Japanese Foundation for Cancer Research
3-8-31 Ariake Koto-ku
Tokyo 135-8550
Japan   

Publication History

Article published online:
15 September 2023

© 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany


Zoom
Fig. 1 Initial placement of a duckbill-type self-expandable metal stent (Duckbill IT Biliary Stent: Kawasumi Laboratories Inc., Tokyo, Japan).
Zoom
Fig. 2 Stent-in-stent placement of a fully covered self-expandable metal stent (HANAROSTENT; Boston Scientific Corp., Marlborough, Massachusetts, USA).
Zoom
Fig. 3 Stent-in-stent-in-stent placement of a duckbill-type self-expandable metal stent (Duckbill Biliary Stent; Kawasumi). The antireflux value can be seen protruding from the second stent.
Zoom
Fig. 4 Sweeping with a stone extraction balloon (Multi-3V Plus, 15 mm; Olympus Medical Systems Corp., Tokyo, Japan) led to migration of the three stents toward the duodenum.
Zoom
Fig. 5 The stent-in-stent-in-stent complex was removed with a snare.