New total knee replacement designs aim to improve patient outcomes through restoration of normal knee joint movements. This study uses in vivo fluoroscopic analysis to quantify the kinematic characteristics of the Physica KR system. Twenty-one patients underwent kinematic fluoroscopic analysis 1 year following implantation of the Physica KR knee using three defined activities (step-up, kneel, and lunge). Assessments were made of initial rollback, maximum flexion, axial rotation, anteroposterior (AP) translation, and the presence or absence of condylar lift-off. A mean maximum passive flexion of 115.8 degrees (standard deviation ± 10.8) was achieved. All joints were congruent throughout range of movement in all three activities. During the step-up activity, the medial femoral condyle exhibited some initial rollback, the lateral condyle moved slightly posteriorly during initial flexion, then back toward its initial alignment with increased flexion. The combined effect produced tibial internal rotation of approximately 5 degrees during the first 90 degrees of flexion with a smooth progression toward slight varus alignment in maximal flexion, with minimal condylar lift-off. During maximal kneeling, both the medial and lateral femoral condyle contact points were just posterior to the AP midline and lift-off of both condyles was noted. During maximal lunge, the medial contact point was slightly anterior to the AP midpoint, with the lateral contact point slightly posterior, resulting in tibial internal rotation. There was no appreciable lift-off of the lateral condyle, although medial condylar lift-off increased from mid-flexion. These in vivo data demonstrate congruent kinematics throughout range of movement, with some initial femoral rollback during early flexion. Our study has shown that the Physica KR knee implant behaved similarly to other established cruciate-retaining implants.
Ethical Approval
Obtained from the Health Research Authority NRES Committee of East England and the University of Florida Institutional Review Board.
Informed Consent
Written informed consent was obtained from each subject prior to participation in the study.
Publication History
Received: 24 April 2025
Accepted: 15 August 2025
Article published online:
01 September 2025
© 2025. Thieme. All rights reserved.
Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
-
References
- 1 Sayah SM, Karunaratne S, Beckenkamp PR. et al. Clinical course of pain and function following total knee arthroplasty: a systematic review and meta-regression. J Arthroplasty 2021; 36 (12) 3993-4002.e37
- 2 Scott CE, Howie CR, MacDonald D, Biant LC. Predicting dissatisfaction following total knee replacement: a prospective study of 1217 patients. J Bone Joint Surg Br 2010; 92 (09) 1253-1258
- 3 Gandhi R, Davey JR, Mahomed NN. Predicting patient dissatisfaction following joint replacement surgery. J Rheumatol 2008; 35 (12) 2415-2418
- 4 Kim TK, Chang CB, Kang YG, Kim SJ, Seong SC. Causes and predictors of patient's dissatisfaction after uncomplicated total knee arthroplasty. J Arthroplasty 2009; 24 (02) 263-271
- 5 Iwaki H, Pinskerova V, Freeman MA. Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee. J Bone Joint Surg Br 2000; 82 (08) 1189-1195
- 6 Pinskerova V, Johal P, Nakagawa S. et al. Does the femur roll-back with flexion?. J Bone Joint Surg Br 2004; 86 (06) 925-931
- 7 Victor J, Bellemans J. Physiologic kinematics as a concept for better flexion in TKA. Clin Orthop Relat Res 2006; 452 (452) 53-58
- 8 Nägerl H, Frosch KH, Wachowski MM. et al. A novel total knee replacement by rolling articulating surfaces. In vivo functional measurements and tests. Acta Bioeng Biomech 2008; 10 (01) 55-60
- 9 Bullens PH, van Loon CJ, de Waal Malefijt MC, Laan RF, Veth RP. Patient satisfaction after total knee arthroplasty: a comparison between subjective and objective outcome assessments. J Arthroplasty 2001; 16 (06) 740-747
- 10 Dennis DA, Komistek RD, Colwell Jr CE. et al. In vivo anteroposterior femorotibial translation of total knee arthroplasty: a multicenter analysis. Clin Orthop Relat Res 1998; (356) 47-57
- 11 Dennis DA, Komistek RD, Mahfouz MR. In vivo fluoroscopic analysis of fixed-bearing total knee replacements. Clin Orthop Relat Res 2003; (410) 114-130
- 12 Kessler O, Dürselen L, Banks S, Mannel H, Marin F. Sagittal curvature of total knee replacements predicts in vivo kinematics. Clin Biomech (Bristol, Avon) 2007; 22 (01) 52-58
- 13 Wachowski MM, Walde TA, Balcarek P. et al. Total knee replacement with natural rollback. Ann Anat 2012; 194 (02) 195-199
- 14 Harvey AR, Barlow IW, Carulli C, Innocenti M, Smith JO. Early outcomes using a ‘kinematic retaining’ total knee replacement - a multicentre prospective study at two years follow-up. Knee 2022; 39: 62-70
- 15 Palm-Vlasak LS, Smith J, Harvey A, Gupta A, Banks SA. Posterior cruciate-retaining total knee arthroplasty exhibits small kinematic changes in the first postoperative year. Knee Surg Sports Traumatol Arthrosc 2023; 31 (03) 914-921
- 16 Grood ES, Suntay WJ. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 1983; 105 (02) 136-144
- 17 Yamazaki T, Watanabe T, Nakajima Y. et al. Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy. Eur J Radiol 2005; 53 (01) 84-89
- 18 Nakamura E, Banks SA, Tanaka A, Sei A, Mizuta H. Three-dimensional tibiofemoral kinematics during deep flexion kneeling in a mobile-bearing total knee arthroplasty. J Arthroplasty 2009; 24 (07) 1120-1124
- 19 Banks SA, Hodge WA. Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng 1996; 43 (06) 638-649
- 20 Tanaka A, Nakamura E, Okamoto N, Banks SA, Mizuta H. Three-dimensional kinematics during deep-flexion kneeling in mobile-bearing total knee arthroplasty. Knee 2011; 18 (06) 412-416
- 21 Park BH, Leffler J, Franz A, Dunbar NJ, Banks SA. Kinematics of monoblock bicompartmental knee arthroplasty during weight-bearing activities. Knee Surg Sports Traumatol Arthrosc 2015; 23 (06) 1756-1762
- 22 Okamoto N, Breslauer L, Hedley AK, Mizuta H, Banks SA. In vivo knee kinematics in patients with bilateral total knee arthroplasty of 2 designs. J Arthroplasty 2011; 26 (06) 914-918
- 23 Banks S, Bellemans J, Nozaki H, Whiteside LA, Harman M, Hodge WA. Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop Relat Res 2003; (410) 131-138
- 24 Ross DS, Howell SM, Hull ML. Errors in calculating anterior-posterior tibial contact locations in total knee arthroplasty using three-dimensional model to two-dimensional image registration in radiographs: an in vitro study of two methods. J Biomech Eng 2017; 139 (12) 139
- 25 Banks SA, Hodge WA. 2003 Hap Paul Award Paper of the International Society for Technology in Arthroplasty. Design and activity dependence of kinematics in fixed and mobile-bearing knee arthroplasties. J Arthroplasty 2004; 19 (07) 809-816
- 26 Moro-oka TA, Hamai S, Miura H. et al. Dynamic activity dependence of in vivo normal knee kinematics. J Orthop Res 2008; 26 (04) 428-434
- 27 Isberg J, Faxén E, Laxdal G, Eriksson BI, Kärrholm J, Karlsson J. Will early reconstruction prevent abnormal kinematics after ACL injury? Two-year follow-up using dynamic radiostereometry in 14 patients operated with hamstring autografts. Knee Surg Sports Traumatol Arthrosc 2011; 19 (10) 1634-1642
- 28 Arauz P, Klemt C, Limmahakhun S, An S, Kwon YM. Stair climbing and high knee flexion activities in bi-cruciate retaining total knee arthroplasty: in vivo kinematics and articular contact analysis. J Arthroplasty 2019; 34 (03) 570-576
- 29 Hazaki S, Yokoyama Y, Inoue H. A radiographic analysis of anterior-posterior translation in total knee arthroplasty. J Orthop Sci 2001; 6 (05) 390-396
- 30 Scott G, Imam MA, Eifert A. et al. Can a total knee arthroplasty be both rotationally unconstrained and anteroposteriorly stabilised? A pulsed fluoroscopic investigation. Bone Joint Res 2016; 5 (03) 80-86
- 31 Kuroyanagi Y, Mu S, Hamai S, Robb WJ, Banks SA. In vivo knee kinematics during stair and deep flexion activities in patients with bicruciate substituting total knee arthroplasty. J Arthroplasty 2012; 27 (01) 122-128
- 32 Key S, Scott G, Stammers JG. et al. Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation. Bone Joint Res 2019; 8 (05) 207-215
- 33 Wilson MD, Kohli S, Smith JO. et al. Mid-term outcomes using a ‘kinematic retaining’ total knee replacement - a multicentre prospective study at five years follow-up. J Orthop 2024; 57: 147-152