Open Access
CC BY 4.0 · Endoscopy 2026; 58(S 01): E154-E155
DOI: 10.1055/a-2767-1833
E-Videos

Use of a Zenker’s diverticulum overtube for the safe extraction of an unusual gastric foreign body

Authors

  • Jose A. González González

    1   Department of Gastroenterology, Hospital Universitario “José Eleuterio González”, Monterrey, Mexico (Ringgold ID: RIN103564)
  • Leticia Santoyo Fexas

    1   Department of Gastroenterology, Hospital Universitario “José Eleuterio González”, Monterrey, Mexico (Ringgold ID: RIN103564)
  • Carlos Eugenio González Martínez

    1   Department of Gastroenterology, Hospital Universitario “José Eleuterio González”, Monterrey, Mexico (Ringgold ID: RIN103564)
  • Juan Méndez-Benítez

    1   Department of Gastroenterology, Hospital Universitario “José Eleuterio González”, Monterrey, Mexico (Ringgold ID: RIN103564)
    2   Instituto Salvadoreño del Seguro Social, Hospital General, San Salvador, El Salvador (Ringgold ID: RIN387240)
  • Cesar Augusto Ramos-Matamoros

    1   Department of Gastroenterology, Hospital Universitario “José Eleuterio González”, Monterrey, Mexico (Ringgold ID: RIN103564)
    3   Hospital Escuela Universitario, Tegucigalpa, Honduras (Ringgold ID: RIN609028)
  • Andrea Guillén Graf

    1   Department of Gastroenterology, Hospital Universitario “José Eleuterio González”, Monterrey, Mexico (Ringgold ID: RIN103564)
  • Aldo Azael Garza

    1   Department of Gastroenterology, Hospital Universitario “José Eleuterio González”, Monterrey, Mexico (Ringgold ID: RIN103564)
 

Foreign body ingestion is a frequent clinical issue particularly in children and also in adults with intoxication, psychiatric or neurological disorders, or institutionalized patients. Although most objects pass spontaneously, up to 20% require endoscopic removal [1]. Management depends on size and shape: blunt items may seem harmless, but these >2–2.5 cm in diameter or >5–6 cm in length are unlikely to pass the pylorus and often need intervention. The choice of a retrieval device is based on the object’s characteristics and endoscopist preference. A practice trial with a similar item can help. Extraction carries a risk of mucosal injury or cervical esophageal impaction. Overtubes protect the esophageal/pharyngeal mucosa and provide a safe conduit for removal [2].

We present a 72-year-old man with Parkinson’s disease admitted for vague abdominal discomfort. He was stable, without dysphagia or vomiting. The family later noticed a missing domino tile. Abdominal radiography revealed a rectangular radiopaque object; computed tomography (CT) confirmed a 5 cm plastic foreign body in the gastric body, without perforation or obstruction.

Given the rigid shape and potential risk of trauma and aspiration, endoscopic removal was attempted using Zenker’s diverticulum overtube ([Video 1]). Under sedation, the overtube was placed in the upper esophagus. Endoscopy located the domino in the gastric body and fundus. A stone retrieval basket captured the tile, aligned on its long axis, and was retracted toward the scope. The object was guided into the distal flaps of the overtube and then both scope and overtube were withdrawn en-bloc through the esophagus and mouth, achieving safe removal ([Fig. 1]).

Zoom
Fig. 1 Distal flaps of Zenker’s diverticulum overtube with the ingested foreign body inside.
Endoscopic removal of a gastric foreign body using Zenker’s diverticulum overtube to assist in the safe extraction through the upper esophagus.Video 1

This case illustrates the successful endoscopic retrieval of a rigid plastic domino tile using Zenker’s diverticulum overtube. The device provided airway protection and facilitated controlled extraction. To our knowledge, this is the first reported use of this overtube for foreign body removal.

Endoscopy_UCTN_Code_TTT_1AO_2AL


Contributorsʼ Statement

Jose A. González González: Conceptualization, Methodology, Supervision, Writing – review & editing. Leticia Santoyo Fexas: Investigation, Software, Writing – original draft. Carlos Eugenio González Martínez: Project administration, Writing – original draft, Writing – review & editing. Juan Méndez-Benítez: Resources, Visualization. Cesar Augusto Ramos-Matamoros: Software, Visualization. Andrea Guillén Graf: Supervision, Validation. Aldo Azael Garza: Methodology.

Conflict of Interest

The authors declare that they have no conflict of interest.

Acknowledgement

We would like to thank Dr. Hector Jesús Maldonado Garza for his invaluable support in this e-video.


Correspondence

Jose A. González González, MD
Department of Gastroenterology, Hospital Universitario “José Eleuterio González”
Francisco I. Madero S/N
64460, Monterrey Nuevo Léon
Mexico   

Publication History

Article published online:
28 January 2026

© 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/).

Georg Thieme Verlag KG
Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany


Zoom
Fig. 1 Distal flaps of Zenker’s diverticulum overtube with the ingested foreign body inside.