Percutaneous endoscopic gastrostomy tube replacement

J.  K.  Turner1 , J.  W.  Berrill1 , S.  Dolwani1 , J.  T.  Green1 , G.  Swift1
  • 1Department of Gastroenterology, University Hospital Llandough, Cardiff, UK
Further Information

J. K. Turner

Department of Gastroenterology
University Hospital Llandough

Penlan Road
Llandough
Vale of Glamorgan
CF64 2XX
UK

Fax: +44-2920-715538

Email: jkturner76@hotmail.com

Publication History

Publication Date:
19 April 2010 (online)

Table of Contents

Percutaneous endoscopic gastrostomy (PEG) tube insertion allows provision of long-term enteral nutrition in patients with dysphagia or those not meeting their nutritional requirement. PEG replacement may be required in patients with significant tube degradation or injury. Single esophageal intubation is preferable, to minimize patient discomfort and reduce the procedural risks associated with upper gastrointestinal endoscopy. Previously described methods of PEG replacement include: passage of the thread through the PEG tube, which is held in place by the plastic introducer [1], and passage of the snare through the thread and then around the PEG tube [2]. However, these methods are either complex to perform or have the potential to lose the guide wire or internal bumper during withdrawal. We describe an easy and reliable method of PEG tube replacement.

The external triangular PEG bumper (Fresenius Kabi, Bad Homburg, Germany) is initially moved away from the abdominal wall. The old PEG tube is transected using a 16-gauge venous cannula or larger, approximately 1 – 2 cm from the skin surface ([Fig. 1]). After removal of the needle, the silk thread is passed through the lumen of the cannula ([Fig. 2]). The plastic cannula is removed from the PEG tube, leaving the thread in situ ([Fig. 3]). The thread is then tied securely around the tube. Following this the PEG tube is cut using scissors or a scalpel blade a further 1 – 2 cm distal to the thread ([Fig. 4]). A snare is placed around the internal bumper to allow removal of the residual external portion of the PEG tube and attached thread through the esophagus. The new PEG tube is then attached to the thread and inserted in the standard manner.

Zoom Image

Fig. 1 A venous cannula is used to transect the old percutaneous endoscopic gastrostomy (PEG) tube.

Zoom Image

Fig. 2 The silk thread is inserted through the cannula.

Zoom Image

Fig. 3 The cannula is withdrawn from the PEG tube.

Zoom Image

Fig. 4 The thread is tied securely around the PEG tube. The tube is then cut 1 – 2 cm below this.

We have routinely employed this technique for several years without complication and recommend it as a simple and effective method for PEG tube replacement.

Competing interests: None

Endoscopy_UCTN_Code_TTT_1AO_2AK

#

References

  • 1 Frenz M B, Heinsohn P, Siuda G, Travis S PL. A reliable method of single-pass endoscopic gastrostomy replacement.  Endoscopy. 2004;  36 754
  • 2 Javaid B, O’Toole P A. Percutaneous endoscopic gastrostomy replacement: a simple and secure technique for combined bumper and wire retrieval.  Endoscopy. 2000;  32 S65

J. K. Turner

Department of Gastroenterology
University Hospital Llandough

Penlan Road
Llandough
Vale of Glamorgan
CF64 2XX
UK

Fax: +44-2920-715538

Email: jkturner76@hotmail.com

#

References

  • 1 Frenz M B, Heinsohn P, Siuda G, Travis S PL. A reliable method of single-pass endoscopic gastrostomy replacement.  Endoscopy. 2004;  36 754
  • 2 Javaid B, O’Toole P A. Percutaneous endoscopic gastrostomy replacement: a simple and secure technique for combined bumper and wire retrieval.  Endoscopy. 2000;  32 S65

J. K. Turner

Department of Gastroenterology
University Hospital Llandough

Penlan Road
Llandough
Vale of Glamorgan
CF64 2XX
UK

Fax: +44-2920-715538

Email: jkturner76@hotmail.com

Zoom Image

Fig. 1 A venous cannula is used to transect the old percutaneous endoscopic gastrostomy (PEG) tube.

Zoom Image

Fig. 2 The silk thread is inserted through the cannula.

Zoom Image

Fig. 3 The cannula is withdrawn from the PEG tube.

Zoom Image

Fig. 4 The thread is tied securely around the PEG tube. The tube is then cut 1 – 2 cm below this.