Endoscopy 2015; 47(05): 453-456
DOI: 10.1055/s-0034-1391077
Innovations and brief communications
© Georg Thieme Verlag KG Stuttgart · New York

Use of a cap in single-balloon enteroscopy-assisted endoscopic retrograde cholangiography

Authors

  • Arvind J. Trindade

    Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
  • Jose M. Mella

    Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
  • Eoin Slattery

    Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
  • Jonah Cohen

    Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
  • Jacob Dickstein

    Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
  • Sagar S. Garud

    Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
  • Ram Chuttani

    Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
  • Douglas K. Pleskow

    Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
  • Mandeep S. Sawhney

    Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
  • Tyler M. Berzin

    Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
Further Information

Publication History

submitted01 January 2014

accepted after revision30 September 2014

Publication Date:
18 December 2014 (online)

Background and study aim: Cannulation of the native papilla in surgically altered anatomy is difficult in endoscopic retrograde cholangiography (ERC). There are limited data regarding the success of single-balloon enteroscopy-assisted ERC (SBE-ERC) in patients with a native papilla and Roux-en-Y gastric bypass. Use of a plastic cap may assist cannulation in these cases. The aim of the current study was to investigate the use of SBE-ERC with a cap (Cap-SBE-ERC) in patients with surgically altered anatomy referred for ERC.

Patients and methods: Patients with surgically altered anatomy (hepaticojejunostomy, gastric bypass surgery, and Whipple’s surgery) who underwent Cap-SBE-ERC were identified from a prospectively maintained database. Outcomes were diagnostic and procedural success. Patients with a native papilla were compared with those with a biliary-enteric anastomosis.

Results: Among 56 patients with surgically altered anatomy, high rates of diagnostic and procedural success were observed (78.6 % and 71.4 %, respectively). High diagnostic and procedural success rates of 72.7 % and 65.9 %, respectively, were also observed for patients with Roux-en-Y gastric bypass anatomy with a native papilla (n = 44).

Conclusion: High rates of diagnostic and procedural success were reported for SBE-ERC with the use of a cap, including a large subgroup of patients with Roux-en-Y gastric bypass and a native papilla.