Endoscopy 2015; 47(05): 453-456
DOI: 10.1055/s-0034-1391077
Innovations and brief communications
© Georg Thieme Verlag KG Stuttgart · New York

Use of a cap in single-balloon enteroscopy-assisted endoscopic retrograde cholangiography

Arvind J. Trindade
Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
,
Jose M. Mella
Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
,
Eoin Slattery
Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
,
Jonah Cohen
Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
,
Jacob Dickstein
Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
,
Sagar S. Garud
Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
,
Ram Chuttani
Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
,
Douglas K. Pleskow
Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
,
Mandeep S. Sawhney
Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
,
Tyler M. Berzin
Center for Advanced Endoscopy, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
› Author Affiliations
Further Information

Publication History

submitted01 January 2014

accepted after revision30 September 2014

Publication Date:
18 December 2014 (online)

Background and study aim: Cannulation of the native papilla in surgically altered anatomy is difficult in endoscopic retrograde cholangiography (ERC). There are limited data regarding the success of single-balloon enteroscopy-assisted ERC (SBE-ERC) in patients with a native papilla and Roux-en-Y gastric bypass. Use of a plastic cap may assist cannulation in these cases. The aim of the current study was to investigate the use of SBE-ERC with a cap (Cap-SBE-ERC) in patients with surgically altered anatomy referred for ERC.

Patients and methods: Patients with surgically altered anatomy (hepaticojejunostomy, gastric bypass surgery, and Whipple’s surgery) who underwent Cap-SBE-ERC were identified from a prospectively maintained database. Outcomes were diagnostic and procedural success. Patients with a native papilla were compared with those with a biliary-enteric anastomosis.

Results: Among 56 patients with surgically altered anatomy, high rates of diagnostic and procedural success were observed (78.6 % and 71.4 %, respectively). High diagnostic and procedural success rates of 72.7 % and 65.9 %, respectively, were also observed for patients with Roux-en-Y gastric bypass anatomy with a native papilla (n = 44).

Conclusion: High rates of diagnostic and procedural success were reported for SBE-ERC with the use of a cap, including a large subgroup of patients with Roux-en-Y gastric bypass and a native papilla.

 
  • References

  • 1 Azeem N, Tabibian JH, Baron TH et al. Use of a single-balloon enteroscope compared with variable-stiffness colonoscopes for endoscopic retrograde cholangiography in liver transplant patients with Roux-en-Y biliary anastomosis. Gastrointest Endosc 2013; 77: 568-77
  • 2 Lennon AM, Kapoor S, Khashab M et al. Spiral assisted ERCP is equivalent to single balloon assisted ERCP in patients with Roux-en-Y anatomy. Dig Dis Sci 2012; 57: 1391-1398
  • 3 Moreels TG. Altered anatomy: enteroscopy and ERCP procedure. Best Practice Res Clin Gastroenterol 2012; 26: 347-357
  • 4 Saleem A, Baron TH, Gostout CJ et al. Endoscopic retrograde cholangiopancreatography using a single-balloon enteroscope in patients with altered Roux-en-Y anatomy. Endoscopy 2010; 42: 656-660
  • 5 Shah RJ, Smolkin M, Yen R et al. A multicenter, U.S. experience of single-balloon, double-balloon, and rotational overtube-assisted enteroscopy ERCP in patients with surgically altered pancreaticobiliary anatomy (with video). Gastrointest Endosc 2013; 77: 593-600
  • 6 Wang AY, Sauer BG, Behm BW et al. Single-balloon enteroscopy effectively enables diagnosic and therapeutic retrograde cholangiography in patients with surgically altered anatomy. Gastrointest Endosc 2010; 71: 641-649
  • 7 Moreels TG, Pelckmans PA. Comparison between double-balloon and single-balloon enteroscopy in therapeutic ERC after Roux-en-Y entero-enteric anastomosis. World J Gastrointest Endosc 2010; 2: 314-317
  • 8 Osoegawa T, Motomura Y, Akahoshi K et al. Improved techniques for double-balloon-enteroscopy assisted endoscopic retrograde cholangiopancreatography. World J Gastroenterol 2012; 18: 6843-6849
  • 9 Choi YR, Han JH, Cho YS et al. Efficacy of cap-assisted endoscopy for routine examining the ampulla of Vater. World J Gastroenterol 2013; 19: 2037-2043
  • 10 Hartmann D, Eickhoff A, Tamm R et al. Balloon-assisted enteroscopy using a single-balloon technique. Endoscopy 2007; 39 (Suppl. 01) E276
  • 11 Kawamura T, Mandai K, Uno K et al. Does single-balloon enteroscopy contribute to successful endoscopic retrograde cholangiopancreatography in patients with surgically altered gastrointestinal anatomy?. ISRN Gastroenterol 2013; 2013: 214958