Nuklearmedizin 1987; 26(06): 248-252
DOI: 10.1055/s-0038-1628898
Review Articles
Schattauer GmbH

Analysis of Myocardial Time-Activity Curves of 123l-Heptadecanoic Acid II. The Acquisition Time

M. J. van Eenige
*   From the Departments of Cardiology, Switzerland
,
F. C. Visser
*   From the Departments of Cardiology, Switzerland
,
A. J. P. Karreman
*   From the Departments of Cardiology, Switzerland
,
C. M. B. Duwel
*   From the Departments of Cardiology, Switzerland
,
G. Westera
***   Free University, Amsterdam, The Netherlands, and Universitätsspital Zürich, Switzerland
,
P. D. Bezemer
**   And Statistics, Switzerland
,
J. P. Roos
*   From the Departments of Cardiology, Switzerland
› Author Affiliations
Further Information

Publication History

Received: 16 March 1987

Publication Date:
05 February 2018 (online)

Optimal fitting of a myocardial time-activity curve is accomplished with a monoexponential plus a constant, resulting in three parameters: amplitude and half-time of the monoexponential and the constant. The aim of this study was to estimate the precision of the calculated parameters. The variability of the parameter values as a function of the acquisition time was studied in 11 patients with cardiac complaints. Of the three parameters the half-time value varied most strongly with the acquisition time. An acquisition time of 80 min was needed to keep the standard deviation of the half-time value within ±10%. To estimate the standard deviation of the half-time value as a function of the parameter values, of the noise content of the time-activity curve and of the acquisition time, a model experiment was used. In most cases the SD decreased by 50% if the acquisition time was increased from 60 to 90 min. A low amplitude/constant ratio and a high half-time value result in a high SD of the half-time value. Tables are presented to estimate the SD in a particular case.

Zusammenfassung

Ein optimaler Fit einer myokardialen Zeitaktivitätskurve wird mit einem monoexponentialen Fit plus einer Konstante erreicht. Es ergeben sich drei Parameter: Amplitude, Halbwertszeit des Monoexponentials und eine Konstante. Die Variation der Parameterwerte im Zusammenhang mit der Akquisitionszeit wurde bei 11 Patienten mit Herzerkrankungen untersucht. Von den drei Parametern variierte die Halbwertszeit am meisten mit der Akquisitionszeit. Eine Akquisitionszeit von 80 min ist notwendig, um die Standardabweichung innerhalb 10% zu halten. Zur Schätzung der Standardabweichung der Halbwertszeit im Zusammenhang mit den Parameterwerten und im Zusammenhang mit der Akquisitionszeit wurde ein Modellexperiment benutzt. Die Standardabweichung der Halbwertszeit nahm um 50% ab, wenn die Akquisitionszeit von 60 auf 90 min verlängert wurde. Ein niedriges Am- plituden/Konstanten-Verhältnis und eine lange Halbwertszeit ergaben eine hohe Standardabweichung der Halbwertszeit. Tabellen zur Schätzung der Standardabweichung bei individuellen Untersuchungen werden vorgelegt.

 
  • REFERENCES

  • 1 Dudczak R. Myokardszintigraphie mit Jod-123- markierten Fettsäuren. Wien. klin. Wschr 1983; 95 (Suppl. 143) 1-35.
  • 2 Dudczak R, Kletter K, Frischauf H. et al. The use of 123-I-labeled heptadecanoic acid (HDA) as metabolic tracer: Preliminary report. Eur. J. nucl. Med 1985; 09: 81-5.
  • 3 Freundlieb C, Hoeck A, Vyska K. Myocardial imaging and metabolic studies with 17-1-123 iodoheptadecanoic acid. J. nucl. Med 1980; 21: 1043-50.
  • 4 Fridrich L, Pichler M, Gassner A. et al. Tracer elimination in I-123-heptadecanoic acid: Halflife, component ratio and circumferential wash outprofiles in patients with cardiac disease. Eur. Heart J 1985; 06 (Suppl. B): 61-70.
  • 5 Hoeck A, Freundlieb C, Vyska K. et al. The influence of rehabilitation training on fatty acid metabolism in patients with myocardial infarction. In: Non-invasive Methods in Ischemic Heart Disease. Faivre G, Bertrand A, Cherrier F, Amor M, Neimann J. L.. (Eds.), 300-3 Specia, Nancy; 1982
  • 6 Hoeck A, Freundlieb C, Vyska K. et al. Myocardial imaging and metabolic studies with 17-1-123 iodoheptadecanoic acid in patients with idiopathic congestive cardiomyopathy. J. nucl. Med 1983; 24: 22-8.
  • 7 Hoeck A, Freundlieb C, Vyska K. et al. The influence of rehabilitation training on fatty acid metabolism in patients with myocardial infarction. In: Non-lnvasive Methods in Ischemic Heart Disease. Faivre G, Bertrand A, Cherrier F, Amor M, Neimann J. L.. (Eds.), 300-3 Specia, Nancy; 1982
  • 8 Kloster G, Stoecklin G, Smith E. F., Schroer K. Omega-halofatty acids: A probe for mitochondrial membrane integrity. In vitro investigations in normal and ischaemic myocardium. Eur. J. nucl. Med 1984; 09: 305-11.
  • 9 Rabinovitch M. A., Kalff V, Allen R. et al. Omega-123-I hexadecanoic acid metabolic probe of cardiomyopathy. Eur. J. nucl. Med 1985; 10: 222-7.
  • 10 Styles C. B., Noujaim A. A., Jugdutt B. I.. et al. Effect of doxorubicin on (omega-I-131) heptadecanoic acid myocardial scintigraphy and echocardiography in dogs. J. nucl. Med 1983; 24: 1012-8.
  • 11 Van der Wall E. E., Den Hollander W, Heidendal G. A.K. et al. Dynamic myocardial scintigraphy with 123-I-labeled free fatty acids in patients with myocardial infarction. Eur. J. nucl. Med 1981; 06: 383-9.
  • 12 Van der Wall E. E., Heidendal G. A. K., Den Hollander W, Westera G, Roos J. P.. Myocardial scintigraphy with 123-1 labelled heptadecanoic acid in patients with unstable angina pectoris. Postgr. med. J 1983; 59 (Suppl. 03) 38-40.
  • 13 Visser F. C., Van Lingen A, Westera G, van Eenige M. J., Roos J. P.. Determination of myocardial FFA elimination rates by functional images of uncorrected half-time values. Nucl.- Med 1984; 23: 277-82.
  • 14 Visser F. C., van Eenige M. J., Van der Wall E. E.. et al. The elimination rate of I-123-hepta- decanoic acid after intracoronary and intravenous administration. Eur. J. nucl. Med 1985; 11: 114-9.