Methods Inf Med 2000; 39(02): 110-113
DOI: 10.1055/s-0038-1634283
Original Article
Schattauer GmbH

EEG/MEG Error Bounds for a Dynamic Dipole Source with a Realistic Head Model

C. Muravchik
1   UNLP/CIC-PBA, USA
,
O. Bria
2   UNLP, La Plata, Argentina, USA
,
A. Nehorai
3   UIC, Chicago Il, USA
› Author Affiliations
Further Information

Publication History

Publication Date:
07 February 2018 (online)

Abstract:

This work presents the background and derivation of Cramér-Rao bounds on the errors of estimating the parameters (moment and location) of a dynamic current dipole source using data from electro- and magneto-encephalography. A realistic head model, based on knowledge of surfaces separating tissues of different conductivities, is used.

 
  • REFERENCES

  • 1 Liegois-Chauvel C, Musolino A, Badier J, Marquiz P, Chauvel P. Evoked potentials recorded from the auditory cortex in man: evaluation and topography of the middle latency components. Electroenceph Clin Neurophysiol 1994; 92: 204-14.
  • 2 Muravchik C, Nehorai A. EEG/MEG error bounds for a dipole source with a realistic head model. To be published.
  • 3 Nehorai A, Dogandzic A. Estimation of propagating dipole sources by EEG/MEG sensor arrays. Proc 32th Asilomar Conf Signals, Syst Comput. Pacific Grove 1998
  • 4 Schwartz D. Localization des Générateures Intra-Cérébraux de l’Activité MEG et EEG: Évaluation de la Précision Spaciale et Temporalle. Thesis for the degree of Doctor, École doctorale Vie et Santé, Université de Rennes; 1998
  • 5 Tichavský P, Muravchik C, Nehorai A. Posterior Cramér-Rao bounds for discrete-time nonlinear filtering. IEEE Trans on Signal Processing 1998; 5: 1386-96.
  • 6 van Trees H. Detection, Estimation and Modulation Theory. New York: John Wiley & Sons; 1968