Endoscopic sphincterotomy (ES), which had been developed by Kawai [1], Classen [2], and Soma et al. [3], has been a very innovative and effective endoscopic procedure to date. However,
ES has also inevitable post-procedural bleeding complications, the so-called “Achilles
Hills of ES.” Mirjalili et al. [4] previously demonstrated the distributions of the arterial supply of the major duodenal
papilla and their relevance to ES according to their pathologic analysis of 19 cadaver
pancreaticoduodenal specimens. Most of the arteries were related to the antero-superior
and postero-inferior quadrants of the major duodenal papilla, both at their point
of entry into the duodenal wall or bile/pancreatic ducts (microdissection) and in
their distribution 5 mm from the tip of the papilla (histology) [4]. Moreover, the combined 10 and 11 oʼclock segments of the papilla (as viewed endoscopically)
contained only 10 % and 11 % of all papillary arteries on microdissection and histology,
respectively, with seven of 19 specimens having no arteries in this region. Based
on their results, they advocated that arterial bleeding as a complication of ES might
be reduced by incising the papilla in the 10 – 11 oʼclock region rather than in the
currently recommended 11 – 1 oʼclock position. However, the axis of the real major
papilla is often rotatable, mainly counter-clockwise.
Furthermore, a special anatomic situation (e. g., periampullary diverticula) causes
confusion about the right axis of the major papilla. Thus, even if endoscopists believe
that the 12 oʼclock position is at the major papilla, this is not always true. These
factors may lead to a wrong direction towards the papilla, causing post-ES bleeding.
Thus far, large prospective studies have in fact reported that the incidence of active
bleeding or ongoing oozing requiring endoscopic hemostasis ranges from 0.76 % to 2.0 %
[5]
[6]
[7].
Several traditional techniques of endoscopic hemostasis for post-ES bleeding exist,
namely, balloon tamponade, local injection of hypertonic saline-epinephrine, and thermal
therapies such as argon plasma coagulation, bipolar coagulation, and/or clipping [8]. However, there is no consensus regarding the optimal endoscopic hemostatic technique
for post-ES bleeding. Monotherapy or combination endotherapies produce very high rates
of success for hemostasis, particularly in case of repeat therapies, but there are
rare or only a few cases in which a conventional hemostatic technique is refractory.
Traditionally, interventional radiology (arterial embolization) or surgical hemostasis
is necessary.
Shah et al. [9] and Itoi et al. [10] previously introduced use of a fully covered self-expandable metal stent (FCSEMS)
as a new hemostasis technique for refractory post-ES bleeding. This technique presents
a new concept of hemostasis achieved by mechanical compression using FCSEMS. In fact,
previous data showed a very high success rate without any serious complications [9]
[10]. Most recently, Cochrane and Schlepp [11] conducted a retrospective non-randomized controlled comparative study between the
FCSEMS group (n = 23) and the non-FCSEMS group (n = 44) in patients with post-ES bleeding
after primary endoscopic intervention failure particularly in patients with a high
risk of post-ES bleeding. Interestingly, although the FCSEMS treatment group had a
significantly lower bleeding rate at 72 hours (0.66 g/dL vs. 1.98 g/dL; P < 0.001), an increased proportion of patients with a high risk of bleeding (40 %
vs. 9 % P = 0.008), and a significantly increased proportion of patients with moderate severity
of bleeding events (52 % vs. 9 % P = 0.0002) were observed compared with the non-FCSEMS treatment group. The FCSEMS
treatment group consisted of 9 patients with increased risk of bleeding but none had
delayed bleeding compared with the 4 patients in the non-FCSEMS group, all of whom
had increased risk of bleeding risk and developed delayed bleeding. Based on their
results, they concluded that FCSEMS can provide homeostasis after primary endoscopic
intervention failure and reduce the need for high-risk procedures.
Is FCSEMS placement suitable for all patients with refractory post-ES bleeding? Previous
reports in the literature did not provide a clear explanation on this point. We presume
that it depends upon the anatomic bleeding point. Post-ES bleeding is well known to
originate largely from the incision area of the major papilla after ES (points A,
B, and C in [Fig. 1]) except for bleeding from the duodenal mucosa far from the cut area although rarely.
All of these points appear suitable for FCSEMS placement. In our experience to date,
complete hemostasis has been achieved at points B and C. As far as point A is concerned,
however, re-bleeding was observed owing to incomplete compression. We infer that FCSEMS
may be insufficient to compress the bleeding point at the most oral side in case of
a relatively large ES incision, hence it may not be useful in this situation. In such
cases, an additional conventional hemostasis technique after FCSEMS placement appears
to be helpful.
Fig. 1 Representative bleeding points after endoscopic sphincterotomy. a Maximum upper oral side of cutting area. b Papillary wall of cutting area. c Bile duct of cutting area.
Stent diameter and stent length are usually not controversial aspects of stent usage.
However, theoretically, from the viewpoint of hemostasis using mechanical compression,
FCSEMS with a stronger radial force or a larger diameter (10 mm) compared with the
original bile duct and expanded biliary orifice appears to be suitable. In terms of
stent length, a longer stent ( ≥ 6 cm) should be suitable to avoid migration into
the bile duct. In fact, several reports have described a high ratio of stent migration
(14.2 %; 3 in 21 patients) [9]
[10]
[12]
[13]. Regarding the type of metal stent, namely, uncovered/partially covered/fully covered
metal stent, although the type of stent depends on the preference of endoscopists
in case of malignant diseases, FCSEMS is ideal in case of benign diseases because
stent removal after hemostasis is possible.
There is currently no solid evidence about when to use or remove a FCSEMS placed for
hemostasis. Our and previous reports suggest that FCSEMS should be placed after the
refractory or ongoing bleeding using mono or combined endoscopic treatment. This should
be reasonable because conventional endoscopic hemostasis techniques are more cost-effective
than FCSEMS placement. However, this method appears to be useful as a rescue technique
in case of massive bleeding or hemorrhage resulting from an undetected bleeding point.
In terms of stent removal in particular, we have no definite information regarding
the duration of stent placement in benign cases. Previous studies have described a
relatively short duration of 1 week to 4 weeks [9]
[10] although Cochran and Schlepp described a longer duration of 88 days.
Care should be taken regarding procedure-related adverse events. FCSEMS with a stronger
radial force and a large diameter may cause acute pancreatitis owing to the obstruction
of the pancreatic duct orifice. We have encountered 3 cases in which acute pancreatitis
occurred by the same mechanism. In such cases, we removed the FCSEMS the following
day. Fortunately, hemostasis was achieved in all cases. Based on our experience, stent
removal appears to be possible in just 1 day after FCSEMS placement.
In conclusion, the recently published CEASE Study by Cochrane and Schlepp in 2016
shows the efficacy of FCSEMS placement as a hemostatic modality for post-ES bleeding
in high-risk patients. Taken together, the indication of FCSEMS placement should be
carefully discussed taking into account information regarding the location of the
bleeding point and the patient’s risk of post-ES bleeding. More extensive prospective
studies and randomized controlled trials are needed to confirm the safety, efficacy,
and long-term outcomes of FCSEMS placement for the treatment of post-ES bleeding.