Thorac Cardiovasc Surg 2023; 71(07): 511-518
DOI: 10.1055/s-0042-1757241
Original Cardiovascular

Rapid-Deployment Aortic Valve Replacement in a Real-World All-Comers Population

Taeyoung Yun
1   Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
,
1   Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
,
Suk Ho Sohn
1   Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
,
Yoonjin Kang
1   Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
,
Ji Seong Kim
1   Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
,
Jae Woong Choi
1   Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
› Author Affiliations
Preview

Abstract

Background This study was conducted to evaluate the mid-term outcomes of rapid-deployment aortic valve replacement (AVR) using Edwards Intuity.

Methods A total of 215 patients underwent rapid-deployment AVR using Edwards Intuity at our institution. The median follow-up duration was 22 months (interquartile range, 8–36). Primary outcomes were overall survival, cumulative incidence of cardiac death, and major adverse cardiac events. Secondary outcomes were early and 1-year hemodynamic performances of the bioprosthetic valve.

Results The mean age was 68.6 ± 10.5 years, and EuroSCORE II was 3.09 ± 4.5. The study population included 113 patients (52.6%) with bicuspid valves (24 patients with type 0 bicuspid valves), 20 patients (9.3%) with pure aortic regurgitation, and 3 patients (1.4%) with infective endocarditis. Isolated AVR was performed in 70 patients (32.4%) and concomitant procedures were performed in 146 patients (67.6%), including aorta surgery (42.3%) and mitral valve procedure (22.3%). Operative mortality was 2.8%. Complete atrioventricular block occurred in 12 patients, but most of them were transient and only 3 patients received permanent pacemaker implantation before discharge. Overall survival at 3 years was 92.3%. Early hemodynamic data showed mean pressure gradients of 15.5 ± 5.0 and 12.7 ± 4.2 mm Hg in the 19 and 21 mm valve, respectively. One-year hemodynamics were also excellent with mean pressure gradients of 14.7 ± 5.3 and 10.7 ± 3.6 mm Hg in the 19 and 21 mm valve, respectively.

Conclusion Based on a real-world all-comers population, rapid-deployment AVR using Edwards Intuity could be performed for various indications, including bicuspid valve, pure aortic regurgitation, and infective endocarditis, and the clinical and hemodynamic outcomes were excellent.

Note

K.H.K. is an official proctor for Edwards Lifesciences.




Publication History

Received: 09 June 2022

Accepted: 23 August 2022

Article published online:
10 October 2022

© 2022. Thieme. All rights reserved.

Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany