Thorac Cardiovasc Surg 2004; 52(6): 374-375
DOI: 10.1055/s-2004-830343
Short Communication

© Georg Thieme Verlag KG Stuttgart · New York

Off-Pump Ascending to Descending Aorta Bypass Grafting with Descending Aneurysm Exclusion

T. Kunihara1 , N. Shiiya1 , T. Oh-oka1 , K. Yasuda1
  • 1Department of Cardiovascular Surgery, Hokkaido University, Sapporo, Japan
Further Information

Publication History

Received April 15, 2004

Publication Date:
01 December 2004 (online)

Abstract

We performed an ascending to descending aorta bypass grafting with exclusion of the descending thoracic aortic aneurysm through a median sternotomy incision without cardiopulmonary bypass in a patient with severe chronic obstructive pulmonary disease. The patient was a 75-year-old man who had undergone endovascular stent-graft placement for a descending thoracic aortic aneurysm. The operation became necessary because the aneurysm continued to expand without evidence of endoleak. The postoperative course was uneventful, and without respiratory morbidity.

References

  • 1 Vijayanagar R, Natarajan P, Eckstein P F, Bognolo D A, Toole J C. Aortic valvular insufficiency and postductal aortic coarctation in the adult. Combined surgical management through median sternotomy: A new surgical approach.  J Thorac Cardiovasc Surg. 1980;  79 266-268
  • 2 Izhar U, Schaff H V, Mullany C J, Daly R C, Orszulak T A. Posterior pericardial approach for ascending aorta-to-descending aorta bypass through a median sternotomy.  Ann Thorac Surg. 2000;  70 31-37
  • 3 Badmanaban B, Sachithanandan A, Sarsam M AI. Transpericardial extra-anatomic intrathoracic aortic bypass conduits in the management of coarctation of the aorta.  J Card Surg. 2002;  17 400-402
  • 4 Sergeant P, de Worm E, Meyns B, Wouters P. The challenge of departmental quality control in the reengineering towards off-pump coronary artery bypass grafting.  Eur J Cardiothorac Surg. 2001;  20 538-543
  • 5 Kunihara T, Shiiya N, Kamikubo Y, Matsui Y, Yasuda K. Midline exposure of the thoracoabdominal aorta.  Ann Thorac Surg. 2000;  69 1951-1953
  • 6 Vassiliades Jr T A. Off-pump apicoaortic conduit insertion for high-risk patients with aortic stenosis.  Eur J Cardiothorac Surg. 2003;  23 156-158
  • 7 Lin C Y, Hong G J, Lee K C, Tsai C S. Successful treatment of Salmonella mycotic aneurysm of the descending thoracic aorta.  Eur J Cardiothorac Surg. 2003;  24 320-322
  • 8 Tovar E A. Stapling of an aortic arch aneurysm.  Ann Thorac Surg. 2001;  71 1011-1013
  • 9 Ku K, Nakayama K, Saitoh Y. et al . Long-term follow-up (8 to 17 years) after thromboexclusion operation for thoracic aortic aneurysms.  Ann Thorac Surg. 1997;  64 399-403

M.D., Ph.D. Takashi Kunihara

Department of Cardiovascular Surgery · Hokkaido University

N14, W5, Kita-ku, Sapporo

Japan 060-8648

Phone: + 81117088896

Fax: + 81 1 17 47 04 76

Email: kunihara@med.hokudai.ac.jp

    >