Endoscopy 2006; 38(3): 289
DOI: 10.1055/s-2006-925214
Unusual Cases and Technical Notes
© Georg Thieme Verlag KG Stuttgart · New York

A Video Capsule Attached to a Probe Can Be Used for Prolonged Stationary Endoscopic Monitoring

M.  Antonietti1 , G.  Savoye1 , S.  Lecleire1 , P.  Hecketsweiler1 , E.  Ben-Soussan1
  • 1 Endoscopic Gastroenterology Unit, Rouen University Hospital Charles Nicolle, Rouen, France
Further Information

M. Antonietti, M.D.

Department of Gastroenterology

Rouen University Hospital Charles Nicolle1 rue de Germont76031 Rouen CedexFrance

Fax: +33-2-35151623

Email: michel.antonietti@chu-rouen.fr

Publication History

Publication Date:
10 March 2006 (online)

Table of Contents

Endoscopic monitoring of the upper gastrointestinal tract could have an important role in the study of bleeding lesions or drug-induced changes in motility. In an attempt to achieve these aims, we assessed the feasibility of using a video capsule (Given Imaging, Yoqneam, Israel), bound to a flexible probe, to make prolonged stationary recordings of areas of interest [1] [2].

Following a Mason operation/bariatric surgery, a 47-year-old woman experienced vomiting due to tight pylorospasm. Balloon dilations led to transient symptomatic improvement; however the pylorospasm recurred. After the patient had given informed consent, we injected 25 U of botulinum toxin into each quadrant of the prepyloric antrum [3]. Then, with the intention of monitoring the relaxation of the pylorus, we carried out the following procedure, with the patient under general anesthesia. A video capsule was fixed to the tip of an enteral feeding tube (Figure [1]). A small wire loop and a long wire were fixed at the proximal and distal ends, respectively, of what was now termed the ”capsule-probe.“ Using a biopsy forceps, the long wire was externalized at the proximal end of the operative channel of a video gastroscope (Olympus XP 160, 5.9 mm) and attached to its handle. The capsule-probe was introduced orally, parallel to the video gastroscope, and then unbound from it. The video gastroscope was reintroduced through a nostril, so that the small proximal wire loop could be grasped with the biopsy forceps, allowing the capsule-probe to be externalized via this nostril. The capsule-probe was fixed in place when the video capsule was facing the area of interest, as checked with the video gastroscope. Finally, the patient was connected to the recording system. The recording provided by the capsule-probe allowed observation of transient pyloric openings.

Zoom Image

Figure 1 Video capsule bound to the probe (the ”capsule-probe“).

We have demonstrated the feasibility of placement and use of the capsule-probe, which allows prolonged recorded observation of specific parts of the upper digestive tract. It could be the first step towards endoscopic monitoring, a previously unreported concept. Such a technique could emerge with the development of a miniaturized video capsule, having the potential for transnasal use, with prolonged recording and immediate reading when coupled with a probe.

In our patient, the capsule-probe was used to study pyloric motility after injections of botulinum toxin. The recording did not allow a definitive conclusion about the efficacy of the treatment, although it did suggest that, prolonged endoscopic observation of motility is possible using a capsule-probe. However the most important potential applications of endoscopic monitoring might relate to upper gastrointestinal bleeding: first, the exact location of small intermittently bleeding lesions (for example Dieulafoy lesions) when their site is only approximately known; and second, the early detection of recurrent hemorrhage of identified bleeding lesions. The intensive care unit of the future might be equipped with screens showing real-time images transmitted from capsule-probes.

Competing interests: None

#

References

  • 1 Iddan G, Meron G, Glukhovsky A, Swain P. Wireless capsule endoscopy.  Nature. 2000;  405 417
  • 2 Lewis B S, Swain P. Capsule endoscopy in the evaluation of patients with suspected small intestinal bleeding: results of a pilot study.  Gastrointest Endosc. 2002;  56 349-353
  • 3 Wiesel P H, Schneider R, Dorta G. et al . Botulinum toxin for refractory postoperative pyloric spasm.  Endoscopy. 1997;  29 132

M. Antonietti, M.D.

Department of Gastroenterology

Rouen University Hospital Charles Nicolle1 rue de Germont76031 Rouen CedexFrance

Fax: +33-2-35151623

Email: michel.antonietti@chu-rouen.fr

#

References

  • 1 Iddan G, Meron G, Glukhovsky A, Swain P. Wireless capsule endoscopy.  Nature. 2000;  405 417
  • 2 Lewis B S, Swain P. Capsule endoscopy in the evaluation of patients with suspected small intestinal bleeding: results of a pilot study.  Gastrointest Endosc. 2002;  56 349-353
  • 3 Wiesel P H, Schneider R, Dorta G. et al . Botulinum toxin for refractory postoperative pyloric spasm.  Endoscopy. 1997;  29 132

M. Antonietti, M.D.

Department of Gastroenterology

Rouen University Hospital Charles Nicolle1 rue de Germont76031 Rouen CedexFrance

Fax: +33-2-35151623

Email: michel.antonietti@chu-rouen.fr

Zoom Image

Figure 1 Video capsule bound to the probe (the ”capsule-probe“).