Endoscopy 2006; 38(8): 841-844
DOI: 10.1055/s-2006-944609
Short communication
© Georg Thieme Verlag KG Stuttgart · New York

Autologous fibrin sealant (Vivostat®) for mesh fixation in laparoscopic transabdominal preperitoneal hernia repair

S.  C.  Schmidt1 , J.  M.  Langrehr1
  • 1 Dept. of General, Visceral, and Transplantation Surgery, University Medicine Berlin, Berlin, Germany
Further Information

Publication History

Submitted 10 April 2006

Accepted after revision 17 May 2006

Publication Date:
28 August 2006 (online)

Abstract

Background and study aims: The use of fibrin glue derived from humans or animals has been reported as an alternative method of mesh fixation, instead of staples, in inguinal hernia repair. However, fibrin sealants involve the potential risks of virus transmission or immunological reactions to foreign proteins. This risk could be avoided by using autologous fibrin derived from the patient. A feasibility study on the use of autologous fibrin was therefore carried out in patients undergoing laparoscopic transabdominal inguinal hernia repair.
Patients and methods: In a series of 10 patients undergoing laparoscopic transabdominal inguinal hernia repair, autologous fibrin was produced from 120 ml of the patient’s blood during the hernia repair. The process took an average of 20 min. The perioperative and postoperative results were compared with those in a control group of 20 patients in whom conventional fibrin was used.
Results: Producing and applying the autologous fibrin was uncomplicated. No differences in the outcome were observed between the two groups. One patient in the conventional fibrin group developed a seroma. None of the patients reported persistent pain. No recurrences were observed after a mean follow-up period of 9 months (range 6 - 12 months) in the conventional fibrin group and 7 months (range 6 - 8 months) in the autologous fibrin group.
Conclusions: This feasibility study suggests that autologous fibrin sealant allowed adequate mesh fixation that did not differ from that in a control group in whom conventional fibrin glue was used. Autologous fibrin may be an interesting alternative for a variety of laparoscopic and endoscopic applications.

References

  • 1 Bittner R, Sauerland S, Schmedt C G. Comparison of endoscopic techniques vs Shouldice and other open nonmesh techniques for inguinal hernia repair: a meta-analysis of randomized controlled trials.  Surg Endosc. 2005;  19 605-615
  • 2 Langrehr J M, Schmidt S C, Neuhaus P. Initial experience with the use of fibrin sealant for the fixation of the prosthetic mesh in laparoscopic transabdominal preperitoneal hernia repair.  Rozhl Chir. 2005;  84 399-402
  • 3 Lau H. Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty: a randomized prospective trial.  Ann Surg. 2005;  242 670-675
  • 4 Novik B, Hagedorn S, Mörk U B. et al . Fibrin glue for securing the mesh in laparoscopic totally extraperitoneal inguinal hernia repair: a study with a 40-month prospective follow-up period.  Surg Endosc. 2006;  20 462-467
  • 5 Topart P, Vandenbroucke F, Lozac’h P. Tisseel versus tack staples as mesh fixation in totally extraperitoneal laparoscopic repair of groin hernias: a retrospective analysis.  Surg Endosc. 2005;  19 724-727
  • 6 Olmi S, Erba L, Bertolini A. et al . Use of fibrin glue (Tissucol) for mesh fixation in laparoscopic transabdominal hernia repair [in Italian].  Chir Ital. 2005;  57 753-759
  • 7 Hino M, Ishiko O, Honda K I. et al . Transmission of symptomatic parvovirus B19 infection by fibrin sealant used during surgery.  Br J Haematol. 2000;  108 194-195
  • 8 Seifert J, Klause N, Stobbe J, Egbers H J. Antibodies formed against fibrin glue components and their circulatory relevance.  J Invest Surg. 1999;  47 167-171
  • 9 Schumpelick V, Artl G. The Aachen classification of inguinal hernia.  Probl Gen Surg. 1995;  12 57-58
  • 10 Kjaergard H K, Trumbull H R. Vivostat system autologous fibrin sealant: preliminary study in elective coronary bypass grafting.  Ann Thorac Surg. 1998;  66 482-486
  • 11 Rosenberger R J, Loeweneck H, Meyer G. The cutaneous nerves encountered during laparoscopic repair of inguinal hernia: new anatomical findings for the surgeon.  Surg Endosc. 2000;  14 731-735
  • 12 Ferzli G S, Frezza E E, Pecoraro A M Jr, Ahern K D. Prospective randomized study of stapled versus unstapled mesh in a laparoscopic preperitoneal inguinal hernia repair.  J Am Coll Surg. 1999;  188 461-465
  • 13 Smith A I, Royston C M, Sedman P C. Stapled and nonstapled laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair: a prospective randomized trial.  Surg Endosc. 1999;  13 804-806
  • 14 Katkhouda N, Mavor E, Friedlander M H. et al . Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair.  Ann Surg. 2001;  233 18-25
  • 15 Petter-Buchner A H, Fortelny R, Mittermayr R. et al . Fibrin sealing versus stapling of hernia meshes in an onlay model in the rat.  Hernia. 2005;  9 322-329
  • 16 Velada J L, Hollingsbee D A. Physical characteristics of Vivostat patient-derived sealant: implications for clinical use.  Eur Surg Res. 2001;  33 399-404

S. C. Schmidt, M. D.

Dept. of General, Visceral, and Transplantation Surgery

Charité Campus, Virchow Clinic · University Medicine Berlin · Augustenburger Platz 1 · 13353 Berlin · Germany

Phone: +49-30-450 652116

Fax: +49-30-4505 52900

Email: sven.schmidt@charite.de

    >