Abstract
Aims: Cryopreserved mitral allograft valve (MAV) offers theoretical advantages over conventional
mechanical or biological prostheses in tricuspid position, especially in infectious
endocarditis patients. MAV processing and tricuspid valve (TV) replacement in a sheep
model is described. Methods and Results: In 20 adult sheep, MAV were harvested, processed and cryopreserved. One month later,
recipient's TV were excised and the MAVs were transplanted into the tricuspid position
in 13 sheep, under general anaesthesia, via a right thoracotomy, with an extracorporeal
circulation (ECC) and cardioplegic heart arrest. Both MAV papillary muscles were anchored
into the right ventricular wall by transmural stitches and the MAV anulus was sewn
into the recipient's tricuspid anulus. After weaning from ECC, the anatomy and function
of the MAV in the tricuspid position was assessed by epicardial echocardiography.
The average duration of the ECC was 58 minutes (42-88), the cardioplegic heart arrest
was 36 minutes (28-45). Weaning from EEC was always uneventful. Right atrial & pulmonary
artery pressure measurements and epicardial echocardiography documented good function
of all MAVs. Conclusion: MAV remained mechanically strong enough for implantation into the tricuspid position.
Reproducible technique of MAV transplantation into the tricuspid position with excellent
early postoperative haemodynamic performance was developed.
Zusammenfassung
Kryopräservierte mitrale Allograft-Klappen (MVA) bieten theoretische Vorteile gegenüber
konventionellen mechanischen oder biologischen Herzklappenprothesen in der Trikuspidalklappenposition,
besonders bei Patienten mit infektiöser Endokarditis. Das Gewinnen dieser Klappen
und der Trikuspidalklappenersatz (TV) in einem Schafmodell werden beschrieben. Material und Methoden: Bei 20 erwachsenen Schafen wurden MVA gewonnen, bearbeitet und kryopräserviert. Nach
einem Monat wurden die Empfängertrikuspidalklappen entfernt und die MVA in die Trikuspidalklappenposition
bei 13 Schafen in Allgemeinbetäubung, über eine rechte Thorakotomie unter Einsatz
der Herz-Lungen-Maschine (HLM) und kardioplegischem Herzstillstand transplantiert.
Beide MVA - Papillarmuskeln wurden in der Wand des rechten Ventrikels mit transmuralen
Stichen verankert und der MVA-Anulus in den Trikuspidalanulus des Empfängers eingenäht.
Nach Abschaltung der HLM wurden die Anatomie und Funktion der MVA in der Trikuspidalposition
mittels epikardialer Echokardiographie überprüft. Die durchschnittliche Zeit der extrakorporalen
Zirkulation betrug 58 Minuten (42-88), des kardioplegischen Herzstillstands 36 Minuten
(28-45). Die Entwöhnung von der Herz-Lungenmaschine verlief ohne Zwischenfälle. Druckmessungen
im rechten Vorhof und der Pulmonalarterie sowie die epikardiale Echokardiographie
dokumentierten eine einwandfreie Funktion der MVA. Folgerung: Kryopräservierte Mitralklappenallografts bleiben mechanisch genügend stabil für die
Implantation in die Trikuspidalposition. Eine reproduzierbare Implantationstechnik
der MVA in die Trikuspidalposition mit exzellenten postoperativen hämodynamischen
Sofortergebnissen wurde entwickelt.
Key words
Mitral allograft valve - infectious endocarditis - tricuspid valve replacement
Schlüsselwörter
Mitralklappenallograft - infektiöse Endokarditis - Trikuspidalklappenersatz
Literature
1
Acar Ch, Iung B, Cormier B, Grare P, Berrebi A, D’Attellis N, Acar J, Carpentier A.
Double mitral homograft for reccurent bacterial endocarditis of the mitral and tricuspid
valves.
J Heart Valve Dis.
1994;
3
470-472
2
Acar Ch, Tolan M, Berrebi A, Gaer J, Gouezo R, Marchix T, Gerota J, Chauvaud S, Fabiani JN,
Deloche A, Carpentier A.
Surgery for acquired heart disease.
J Thorac Cardiovasc Surg.
1996;
111
367-380
3
Arbulu A, Holmes RJ, Asfaw I.
Surgical treatment of intractable right-side endocarditis in drug addicts: 25 years’experience.
J Heart Valve Dis.
1993;
2
129-137
4
Bernal JM, Rabasa JM, Cagigas JC, Val F, Revuelta JM.
Behavior of mitral allografts in the tricuspid position in the growing sheep model.
Ann Thorac Surg.
1998;
65
1326-1330
5
Bodnar E.
Editorial. Clinical use of homologous and heterologous mitral valves.
J Heart Valve Dis.
1994;
3
468-469
6
Chauvaud S, Waldmann T, d’Attellis N, Bruneval P, Acar C, Gerota J, Jarraya M, Carpentier A.
Homograft replacement of the mitral valve in young recipients: mid-term results.
Eur J Cardiothoirac Surg.
2003;
23
560-566
7
Glower DD, White WD, Smith LR, Zouny WG, Oldham HN, Wolfe WG, Lowe JE.
In-hospital and long-term outcome after porcine tricuspid valve replacement.
J Thorac Cardiovasc Surg.
1995;
109
877-883
8
Hubka M, Siska K, Brozman M, Holec V.
Replacement of mitral and tricuspid valves by mitral homograft.
J Thorac Cardiovasc Surg.
1966;
51
195-204
9
Hvass U, Baron F, Fourchy D, Pansard Y.
Mitral homografts for total tricuspid valve replacement: comparison of two techniques.
J Thorac Cardiovasc Surg.
2001;
121
592-594
10
Kaplan M, Kut MS, Demirtas MM, Cimen S, Ozler A.
Prosthetic replacement of tricuspid valve: bioprosthetic or mechanical.
Ann Thorac Surg.
2002;
73
467-473
11
Kumar AS, Choudhary SK, Mathur A, Saxena A, Roy R, Chopra P.
Homograft mitral valve replacement: five years’results.
J Thorac Cardiovasc Surg.
2000;
120
450-458
12
Mestres CA, Miro JM, Pare JC, Pomar JL.
Six-year experience with cryopreserved mitral homografts in the treatment of tricuspid
valve endocarditis in HIV - infected drug addicts.
J Heart Valve Dis.
1999;
8
575-577
13
Miyagishima RT, Brumwell ML, Jamieson WRE, Munt BI.
Tricuspid valve replacement using a cryopreserved mitral homograft. Surgical technique
and initial results.
J Heart Valve Dis.
2000;
9
805-808
14
Nakano K, Ishibashi-Ueda H, Kobayashi J, Sasako Y, Yagihara T.
Tricuspid valve replacement with bioprotheses: long-term results and causes of valve
dysfunction.
Ann Thorac Surg.
2001;
71
105-109
15
Pomar JL, Mestres CA.
Tricuspid valve replacement using a mitral homograft. Surgical technique and initial
results.
J Heart Valve Dis.
1993;
2
125-128
16
Špatenka J, Honěk T, Kostelka M, Huěín B, Fišer B, Hájek T, Povýšilová V, Kobylka P.
Harvesting the heart for preparation of heart valve allografts.
Rozhl Chir.
1997;
76
113-117
17
Špatenka J, Kostelka M, Kobylka P, Hučín B, Honěk T, Lochman O, Hájek T, Tláskal T,
Povy`šilová V, Fišer B.
Preparation, storage, transportation and use of heart valves for allotransplantation.
Rozhl Chir.
1997;
76
118-125
18
Tamura K, Jones M, Yamada I, Ferrans JV.
A comparison of failure modes of glutaraldehyde-treated versus antibiotic-preserved
mitral valve allografts implanted in sheep.
J Thorac Cardiovasc Surg.
1995;
110
224-238
Korrespondenzadresse
Jan VojacekM.D.
Department of Cardiac Surgery & Transplant Centre
University Hospital Motol
V Úvalu 84
155 00 Prague 5
Czech Republic
Phone: Tel: +420/2 24 43 52 50
Fax: Fax: +420/2 24 43 52 20
Email: j.vojacek@fnmotol.cz