Background and study aims: The endoscopes that were developed for double-balloon enteroscopy have been successfully
used in cases of failed colonoscopy. This study was a pilot series in which a new
colonoscope was tested that utilized this double-balloon principle.
Patients and methods: A total of 29 patients (5 men, 24 women; mean age 54 years) in whom conventional
colonoscopy had failed were included in this study. Both the failed colonoscopy and
the double-balloon colonoscopy procedures were performed under general anesthesia,
the usual practice in France. A prototype instrument (working length 152 cm, diameter
9.4 mm) designed to incorporate the principles of double-balloon enteroscopy was used.
The completeness of colonoscopy was assessed according to conventional criteria by
the achievement of a stable position in the cecum. The indicatons for the procedure,
the time to reach the cecum, the need for fluoroscopic control, and adverse events
were recorded.
Results: The previous colonoscopy failed due adhesions (n = 16), or to long or fixed loops
(n = 13). Complete colonoscopy using the balloon method was achieved in 28/29 patients,
taking an average time of 18 ± 14 minutes; a long sigmoid loop limited the examination
to the left flexure in one patient. Balloon colonoscopy using double-balloon methodology
was used in 24 patients and the instrument was used without an overtube (i. e. using
a single-balloon technique) in five patients. Fluoroscopy was used in 16 patients
to monitor endoscope progression. No complications were reported.
Conclusions: Double-balloon colonoscopy enables full colonic examination in almost all patients
with a previous incomplete colonoscopy. The overtube should be used in most cases.
The use of fluoroscopic assessment of scope progression could be reduced further with
increasing experience.
References
- 1
Micksche M, Lynge E, Diehl V. et al .
and Groupe des Experts Cancérologue de l’Union Européenne. Recommendations on cancer
screening in the European Union [in French, no abstract].
Bull Cancer.
2001;
88
687-692
- 2
Anderson J C, Gonzalez J D, Messina C R, Pollack B J.
Factors that predict incomplete colonoscopy: thinner is not always better.
Am J Gastroenterol.
2000;
95
2784-2787
- 3
Waye J D, Yessayan S A, Lewis B S, Fabry T L.
The technique of abdominal pressure in total colonoscopy.
Gastrointest Endosc.
1991;
37
147-151
- 4
Belaiche J, van Kemseke C, Louis E.
Use of the enteroscope for colo-ileoscopy: low yield in unexplained lower gastrointestinal
bleeding.
Endoscopy.
1999;
31
298-301
- 5
Marshall J B, Perez R A, Madsen R W.
Usefulness of a pediatric colonoscope for routine colonoscopy in women who have undergone
hysterectomy.
Gastrointest Endosc.
2002;
55
838-841
- 6
Rex D K, Goodwine B W.
Method of colonoscopy in 42 consecutive patients presenting after prior incomplete
colonoscopy.
Am J Gastroenterol.
2002;
97
1148-1151
- 7
Ruffolo T A, Lehman G A, Rex D.
Colonoscope damage from internal straightener use.
Gastrointest Endosc.
1991;
37
107-108
- 8 Yamamoto H, Kita H, Sugano K.
Other applications of double balloon technique. In: Sugano K, Yamamoto H, Kita H (eds). Double balloon endoscopy. Heidelberg; Springer
2006: 101-113
- 9
May A, Nachbar L, Ell C.
Push-and-pull enteroscopy using a single-balloon technique for difficult colonoscopy.
Endoscopy.
2006;
38
395-398
- 10
Napoleon B, Ponchon T, Lefebvre R. et al .
French Society of Digestive Endoscopy (SFED) guidelines on performing a colonoscopy.
Endoscopy.
2006;
38
1152-1155
- 11
Yamamoto H, Sekine Y, Sato Y. et al .
Total enteroscopy with a nonsurgical steerable double-balloon method.
Gastrointest Endosc.
2001;
53
216-220
- 12
Vucelic B, Rex D, Pulanic R. et al .
The Aer-O-Scope: proof of concept of a pneumatic, skill-independent, self-propelling,
self-navigating colonoscope.
Gastroenterology.
2006;
130
672-677
- 13
Horiuchi A, Nakayama Y, Kajiyama M. et al .
Usefulness of a small-caliber, variable-stiffness colonoscope as a backup in patients
with difficult or incomplete colonoscopy.
Am J Gastroenterol.
2004;
99
1936-1940
- 14
Rösch T, Adler A, Wiedenman B H, Hoepffner N.
A prospective pilot study to assess technical performance of a new single use colonoscope
with inverted sleeve technology [abstract].
Gastrointest Endosc.
2007;
65
AB340
M. Delvaux, MD
Department of Internal Medicine and Digestive Diseases
Hôpitaux de Brabois Adultes
CHU de Nancy
F-54511 Vandoeuvre les Nancy
France
Fax: +33-383154012
Email: 106521.3337@compuserve.com